Page 30
MODELS: WS-48511 / WS-55511 / WS-55711 / WS-65511 / WS-65611 / WS-65711 / WS-65712 / WS-73711 / WS-B55
C. A/V Memory
Each of the external inputs has its’ own Audio/Video Memory. A change in an A/V setting at a specific input is
stored in memory for that specific input.
A/V Reset
1. The front panel AV Reset button initializes all A/V Memories.
2. The AV Reset in the user’s menu initializes only the selected input’s A/V Memory.
LED Indicator Diagnostics
The “Power ON LED” provides an indication of the sets operation, and the possible cause of a malfunction.
1. Initial Control Circuitry Check
Immediately after the TV is connected to an AC power source:
2. Error Code Operational Check
Pressing the front panel “INPUT” and “MENU” buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The LED flashes denoting a two digit Error Code, or indicating no problem
has occured since the last Initalization.
Note:
The front panel buttons must used, NOT those on the Remote Control.
•
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
•
The flashing then pauses for approximately 1/2 second.
•
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
•
The Error Code is repeated a total of 5 times.
Example: If the Error Code is “24”, the LED will flash two times, pause, and then flash four
times.
3. Error Codes
The Error Code designations indicating a malfunction, or no malfunction, are listed below:
Remote Control Operational Modes
There are two Remote Hand Unit Operational Modes, “Standard” and “NetCommand
TM
”. The Remote is initially
in
in the “Standard” mode. The “NetCommand
TM
” mode is used when controlling Home Theater devices using
NetCommand
TM
. To change the Remote Operational Mode:
• Set the Remote to the TV Layer
•
Point the Remote away from the TV.
•
To change to “Netcommand
TM
” ... Hold the “Power” button and press “9-3-5” in sequence.
•
To change to “Standard” ... Hold the “Power” button and press “0-0-0” in sequence.
LED Indications
Conditions
Probable Cause
Off
After AC is applied Standy Power Supply or TV µPC not running
Fast Blink for 70 sec.
After AC is applied Normal - DM µPC is booting up
Fast Blink (doesn't stop)
After AC is applied TV µPC is running, but DM failed to boot up
Slow Blink
Set is Off
Normal - Timer is set for Automatic Turn ON
Error Code
Probable Cause
12
Normal Operation - No Error Detected
21
X-Ray Protect
22
Short Protect
23
Loss of Horizontal Deflection
24
Loss of Vertical Deflection
Содержание WS-B55
Страница 2: ......
Страница 76: ...MODELS WS 48511 WS 55511 WS 55711 WS 65511 WS 65611 WS 65711 WS 65712 WS 73711 WS B55 Page 76 DM POWER SUPPLY ...
Страница 79: ...MODELS WS 48511 WS 55511 WS 55711 WS 65511 WS 65611 WS 65711 WS 65712 WS 73711 WS B55 Page 79 SYNC PATH ...
Страница 81: ...MODELS WS 48511 WS 55511 WS 55711 WS 65511 WS 65611 WS 65711 WS 65712 WS 73711 WS B55 Page 81 SOUND CIRCUIT ...
Страница 83: ...MODELS WS 48511 WS 55511 WS 55711 WS 65511 WS 65611 WS 65711 WS 65712 WS 73711 WS B55 Page 83 CONTROL CIRCUIT ...
Страница 85: ......
Страница 86: ......
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......