background image

 © 2017 Mitsubishi Electric US, Inc.             

                                                    Specifications are subject to change without notice. 

 

PUY/Z-A24/30/36NHA4/NHA6; PUY/Z-A42NHA4/NHA5 

PUZ-HA30/36NA4; PUMY-P36/48NHMU; PUY/Z-A24/A30NHA7 

Outdoor Units

MANUFACTURED FOR:

MITSUBISHI ELECTRIC US, INC.

Installation Instructions

Wind Baffle  Part # WB-PA2

1. Remove 5 screws holding fan guard in place.

2. Slide fan guard into wind baffle lining up the stopper tabs.

3. Position wind baffle/fan guard and line up with pre-punched holes.

4. Install all 5 screws and tighten securely. Repeat with all baffles.

Note: When two fan outdoor unit is used, two wind baffles are required.

          Install lower baffle first for easier installation.

STEP 1

STEP 2

STEP 3

STEP 4

Manufactured for Mitsubishi Electric US, Inc. 

© 2012 Mitsubishi Electric US, Inc.

Sep 2015

WARNING! MOVING PARTS. INCORRECT HANDLING COULD LEAD TO DEATH OR INJURY!

IMPORTANT! Outdoor Unit should be installed with back coil surface facing a wall or oriented 

so the wind does NOT blow directly on to the back coil surface. Do not install this product 

where there is any obstacle at either side or above the outdoor unit. If the discharge air is 

obstructed the air may be short cycled.

Steps:

ENSURE BAFFLE OUTLETS WILL NOT BE BLOCKED OR OBSTRUCTED !

5. Attach the safety string to the lower left inside of baffle using the pre-punched hole 

and the provided 10-24 screw and nylon lock nut. Attach the other end to the closest 

existing cabinet screw.  Repeat with all baffles.

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the advanced wind baffles.

English

FOR INSTALLER

    WARNING! MOVING PARTS. INCORRECT HANDLING COULD LEAD TO DEATH OR INJURY!

IMPORTANT! Outdoor Unit should be installed with back coil surface facing a wall or oriented so the wind 

does NOT blow directly on to the back coil surface. Do not install this product where there is any obstacle at 

either side or above the outdoor unit. If the discharge air is obstructed the air may be short cycled.

STEPS: 

1. Remove four(4) or five(5) screws holding fan guard in place.

2. Slide fan guard into wind baffle lining up the stopper tabs.

3. Position wind baffle/fan guard and line up with pre-punched holes.

4. Install all four(4) or five(5) screws and tighten securely. Repeat with all baffles.

Note: When two fan outdoor unit is used, two wind baffles are required.

          Install lower baffle first for easier installation.

Wind Baffle

WB-PA5

for use with:

Installation Instructions

Wind Baffle  Part # WB-PA2

1. Remove 5 screws holding fan guard in place.

2. Slide fan guard into wind baffle lining up the stopper tabs.

3. Position wind baffle/fan guard and line up with pre-punched holes.

4. Install all 5 screws and tighten securely. Repeat with all baffles.

Note: When two fan outdoor unit is used, two wind baffles are required.

          Install lower baffle first for easier installation.

STEP 1

STEP 2

STEP 3

STEP 4

Manufactured for Mitsubishi Electric US, Inc. 

© 2012 Mitsubishi Electric US, Inc.

Sep 2015

WARNING! MOVING PARTS. INCORRECT HANDLING COULD LEAD TO DEATH OR INJURY!

IMPORTANT! Outdoor Unit should be installed with back coil surface facing a wall or oriented 

so the wind does NOT blow directly on to the back coil surface. Do not install this product 

where there is any obstacle at either side or above the outdoor unit. If the discharge air is 

obstructed the air may be short cycled.

Steps:

ENSURE BAFFLE OUTLETS WILL NOT BE BLOCKED OR OBSTRUCTED !

5. Attach the safety string to the lower left inside of baffle using the pre-punched hole 

and the provided 10-24 screw and nylon lock nut. Attach the other end to the closest 

existing cabinet screw.  Repeat with all baffles.

ENSURE BAFFLE OUTLETS WILL NOT BE BLOCKED OR OBSTRUCTED !

stopper or wire tab

stopper 