En-13

● OPERATING INSTRUCTIONS ●

Even if these items are checked, when the unit does not recover from the 

trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?

•  Is the power supply plug connected?

•  Is the ON timer set? 

 Page 9 

The horizontal vane does not 

move.

•  Are the horizontal vane and the vertical vane 

installed correctly?

•  Is the fan guard deformed? 

•  When the breaker is turned on, the horizontal 

vanes’ position will be reset in about a minute. 

After the reset has completed, the normal hori-

zontal vanes’ operation resumes. The same is 

true in the emergency cooling operation.

The unit cannot be operated for 

about 3 minutes when restarted.

•  This protects the unit according to instructions 

from the microprocessor. Please wait.

Mist is discharged from the air 

outlet of the indoor unit.

• 

The cool air from the unit rapidly cools moisture 

in the air inside the room, and it turns into mist.

The swing operation of the HORI-

ZONTAL VANE is suspended for a 

while, then restarted.

•  This is for the swing operation of the HORIZON-

TAL VANE to be performed normally.

When SWING is selected in 

COOL/DRY/FAN mode, the 

lower horizontal vane does not 

move.

•  It is normal that the lower horizontal vane does 

not move when SWING is selected in COOL/

DRY/FAN mode.

The airfl ow direction changes 

during operation.

The direction of the horizontal 

vane cannot be adjusted with 

the remote controller.

•  When  the  unit  is  operated  in  COOL  or  DRY 

mode, if the operation continues with air blow-

ing down for 0.5 to 1 hour, the direction of the 

airfl ow is automatically set to upward position 

to prevent water from condensing and dripping.

•  In  the  heating  operation,  if  the  airfl ow  tem-

perature is too low or when defrosting is being 

done, the horizontal vane is automatically set 

to horizontal position.

The operation stops for about 

10 minutes in the heating 

operation.

•  Outdoor unit is in defrost.

 

Since  this  is  completed  in  max.10  minutes, 

please wait. (When the outside temperature is 

too low and humidity is too high, frost is formed.)

The unit starts operation by 

itself when the main power is 

turned on, but hasn’t received 

sign from the remote controller.

•  These  models  are  equipped  with  an  auto 

restart  function.  When  the  main  power  is 

turned  off  without  stopping  the  unit  with  the 

remote controller and is turned on again, the 

unit starts operation automatically in the same 

mode as the one set with the remote control-

ler just before the shutoff of the main power. 

Refer to “Auto restart function”. 

 Page 12 

The two horizontal vanes touch 

each other. The horizontal 

vanes are in an abnormal posi-

tion. The horizontal vanes do 

not return to the correct “close 

position”.

Perform one of the following: 

• 

Turn off and on the breaker. Make sure the hori-

zontal vanes move to the correct “close position”.

•  Start and stop the emergency cooling operation 

and make sure the horizontal vanes move to the 

correct “close position”.

The indoor unit discolors over 

time.

•  Although plastic turns yellow due to the infl uence 

of  some  factors  such  as  ultraviolet  light  and 

temperature, this has no effect on the product 

functions.

Multi system

The indoor unit which is not 

operating becomes warm and a 

sound, similar to water fl owing, 

is heard from the unit.

•  A small amount of refrigerant continues to fl ow 

into the indoor unit even though it is not operat-

ing.

When heating operation is 

selected, operation does not 

start right away.

•  When operation is started during defrosting of 

outdoor unit is done, it takes a few minutes (max. 

10 minutes) to blow out warm air.

Outdoor Unit

The fan of the outdoor unit does 

not rotate even though the com-

pressor is running. Even if the 

fan starts to rotate, it stops soon.

•  When  the  outside  temperature  is  low  during 

cooling operation, the fan operates intermittently 

to maintain suffi cient cooling capacity.

Water leaks from the outdoor 

unit.

•  During COOL and DRY operations, pipe or pipe 

connecting sections are cooled and this causes 

water to condense.

•  In the heating operation, water condensed on 

the heat exchanger drips down.

•  In the heating operation, the defrosting operation 

makes ice forming on the outdoor unit melt and 

drip down.

White smoke is discharged from 

the outdoor unit.

•  In the heating operation, vapor generated by the 

defrosting operation looks like white smoke.

Remote controller

The display on the remote 

controller does not appear or it 

is dim. The indoor unit does not 

respond to the remote control 

signal.

•  Are the batteries exhausted? 

 Page 4 

•  Is  the  polarity  (+,  -)  of  the  batteries  correct?

 Page 4 

•  Are any buttons on the remote controller of other 

electric appliances being pressed?

Symptom

Explanation & Check points

Does not cool or heat

The room cannot be cooled or 

heated suffi ciently.

•  Is the temperature setting appropriate? 

 

 Page 6 

•  Is  the  fan  setting  appropriate?  Please  change 

fan speed to High or Super High. 

 Page 7 

•  Are the fi lters clean? 

 Page 11 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

•  Are there any obstacles blocking the air inlet or 

outlet of the indoor or outdoor unit?

•  Is a window or door open?

•  When a ventilation fan or a gas cooker is used 

in a room, the cooling load increases, resulting 

in an insuffi cient cooling effect.

•  When the outside temperature is high, the cooling 

effect may not be suffi cient.

•  It may take a certain time to reach the setting 

temperature or may not reach that depending on 

the size of the room, the ambient temperature, 

and the like.

The room cannot be cooled 

suffi ciently.

•  When a ventilation fan or a gas cooker is used 

in a room, the cooling load increases, resulting 

in an insuffi cient cooling effect.

•  When the outside temperature is high, the cooling 

effect may not be suffi cient.

The room cannot be heated 

suffi ciently.

•  When the outside temperature is low, the heating 

effect may not be suffi cient.

Air does not blow out soon in 

the heating operation.

•  Please wait as the unit is preparing to blow out 

warm air.

Airfl ow

The air from the indoor unit 

smells strange.

•  Are the fi lters clean? 

 Page 11 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it out 

with the air.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/con-

traction of the front panel, etc. due to change in 

temperature.

“Burbling” sound is heard.

•  This  sound  is  heard  when  the  outside  air  is 

absorbed from the drain hose by turning on the 

range hood or the ventilation fan, making water 

fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows  into  the  drain  hose  in  case  the  outside 

wind is strong.

Mechanical sound is heard 

from the indoor unit.

•  This is the switching sound in turning on/off the 

fan or the compressor.

The sound of water fl owing is 

heard.

• This is the sound of refrigerant or condensed 

water fl owing in the unit.

Hissing sound is sometimes 

heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is changed.

Timer

Weekly timer does not operate 

according to settings.

•  Is the ON/OFF timer set? 

 Pages 9, 10 

•  Transmit  the  setting  information  of  the  weekly 

timer to the indoor unit again. When the infor-

mation is successfully received, a long beep will 

sound from the indoor unit. If information fails to 

be received, 3 short beeps will be heard. Ensure 

information is successfully received. 

 Page 10 

•  When a power failure occurs and the main power 

turns  off,  the  indoor  unit  built-in  clock  will  be 

incorrect. As a result, the weekly timer may not 

work normally.

  Be  sure  to  place  the  remote  controller  where 

the  signal  can  be  received  by  the  indoor  unit.

 Page 3 

The unit starts/stops the opera-

tion by itself.

•  Is the weekly timer set? 

 Page 10 

In the following cases, stop using the air conditioner and consult your dealer.

•  When water leaks or drips from the indoor unit.

•  When the operation indicator lamp blinks. Except for when the lamp of a multi 

unit blinks while the unit is on standby.

•  When the breaker trips frequently.

•  The remote control signal is not received in a room where an electronic ON/

OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

•  When any refrigerant leakage is found.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

JG79Y768H01_01En.indd   13

2020/06/19   9:53:01

Содержание Trane NTXWPH06B112A Series

Страница 1: ...UTILISATION A l attention des clients Pour avoir la certitude d utiliser cet appareil correctement et en toute sécurité veuillez lire cette notice d instructions avant de mettre le clima tiseur sous tension Español MANUAL DE INSTRUCCIONES Para los clientes Para utilizar esta unidad de forma correcta y segura lea previamente estas instrucciones de funcionamiento SPLIT TYPE AIR CONDITIONERS JG79Y768...

Страница 2: ... mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appli ance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at ...

Страница 3: ...pliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons perform inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor contribute to growth of fung...

Страница 4: ...r Slide it down further to get to the weekly timer buttons Install the remote con troller holder in a place where the signal can be received by the indoor unit When the remote con troller is not used place it in this holder Only use the remote controller provid ed with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit ...

Страница 5: ...power supply plug into the power outlet and or turn the breaker on Installing the remote controller batteries 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3 Install the front lid 4 Press RESET Note Make sure the polarity of the batteries is correct Do not use manganese batteries and leaking batteries The remote controller could malfunction Do not use rechargeabl...

Страница 6: ...ode is also cancelled when the VANE or WIDE VANE buttons is pressed Note Do not touch the i see sensor This may cause malfunction of the i see sen sor The intermittent operating sound is a normal sound produced when the i see sensor is moving from side to side Press during COOL DRY HEAT and AUTO mode to activate the i see control mode Press gently using a thin instrument lights Operation display s...

Страница 7: ...ystem operation Lit Blinking Not lit AUTO mode Auto change over The unit selects the operation mode according to the difference between the room temperature and the set temperature During AUTO mode the unit changes mode COOL HEAT when the room temperature is about 4 F 2 C away from the set temperature for more than 15 minutes Note Auto Mode is not recommended if this indoor unit is connected to a ...

Страница 8: ...irection in the following order Two short beeps are heard from the indoor unit when set to AUTO Always use the remote controller when changing the direction of air flow Moving the horizontal vanes with your hands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency coo...

Страница 9: ...ress again to cancel SMART SET operation SMART SET operation also is cancelled when the MODE button is pressed Note SMART SET operation cannot be set on the weekly timer Example of use 1 Low energy mode Set the temperature 4 F 2 C to 6 F 3 C warmer in COOL and cooler in HEAT mode This setting is suitable for unoccupied room and while you are sleeping 2 Saving frequently used settings Save your pre...

Страница 10: ...tion is also cancelled automatically in 15 minutes or when the ON OFF FAN ECONO COOL NATURAL FLOW or i save button is pressed POWERFULOPERATION 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time and day are set correctly Page 4 2 Press forward and backward to set the time of ...

Страница 11: ...er is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is included among them will be displayed which was blink ing goes out and the current time will be displaye...

Страница 12: ...f the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 2330FT E Pull to remove from the air filter Deodorizing filter black Every 3 months Remove dirt by a vacuum cleaner or soak the framed filter in lukewarm water 86 to 104 F 30 to 40 C for about 15 minutes Rinse well After washing dry it well in shade Deodorizing feature recovers by cleaning the fil...

Страница 13: ...ting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult the service repre sentative because the setting of the unit needs to be changed Set temperature 75 F 24 C Fan speed Medium Horizontal vane Auto Emergency COOL Emergency HEAT Stop Note The first 30 minutes of operation is test run Temperature control does not work and fan spee...

Страница 14: ...ps down In the heating operation the defrosting operation makes ice forming on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal...

Страница 15: ...stalled in a well ventilated dry place TV Cordless phone or Portable phone 10 ft 3 m or more 3 ft 1 m or more The installation location of the outdoor unit should be at least 10 ft 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes...

Страница 16: ...ue lo hagan bajo la supervisión o ins trucción relativa al uso del aparato por una persona responsable de su seguridad Se debe supervisar a los niños para garantizar que no jueguen con el aparato Puesto que este producto tiene piezas rotatorias y piezas que pueden provocar des cargas eléctricas lea atentamente las Medidas de seguridad antes de usarlo Tome las precauciones aconsejadas en este manua...

Страница 17: ... Una ventilación inadecuada puede originar falta de oxígeno Coloque el disyuntor en OFF si oye truenos y hay posibilidad de que caigan rayos La unidad puede resultar dañada si cae algún rayo Tras varias estaciones con el acondicionador de aire en funciona miento efectúe una inspección y el mantenimiento además de la limpieza habitual Si hay polvo o suciedad en la unidad se puede producir un olor d...

Страница 18: ...s para llegar a los botones del temporizador semanal Instale el soporte del controlador remoto en un lugar en el que la unidad interior pueda recibir la se ñal Si no está usando el con trolador remoto colóquelo en su soporte Use únicamente el controlador remo to suministrado con la unidad No use otro controlador remoto Si dos o más unidades interiores es tán instaladas cerca unas de otras puede qu...

Страница 19: ... el enchufe de alimentación en la toma de corriente y o encienda el disyuntor Instalación de las pilas del controlador remoto 1 Retire la tapa frontal 2 Inserte primero el polo negativo de las pilas alcalinas tipo AAA 3 Coloque la tapa frontal 4 Pulse RESET Nota Pulse CLOCK temporizador suavemente utilizando un objeto en punta Ajuste de la hora actual 1 Pulse CLOCK 4 Pulse otra vez CLOCK 2 Pulse e...

Страница 20: ...ra mal El sonido de funcionamiento intermitente es un sonido normal que se produ ce cuando el sensor i see se mueve de un lado a otro 1 2 Para activar el modo de control i see pulse duran te el modo COOL refrigeración DRY deshumidifica ción HEAT calefacción y AUTO Púlselo suavemente usando un objeto fino Se iluminará Sección de la pantalla de accionamiento El ajuste predeterminado es activado Pulse...

Страница 21: ...TO Cambio automático La unidad selecciona el modo de funcionamiento de acuerdo con la diferencia que haya entre la temperatura ambiente y la temperatu ra establecida Durante el modo AUTO la unidad cambia el modo REFRIGERACIÓN CALEFACCIÓN cuando la temperatura ambiente difiere en aproximadamente 4 F 2 C de la temperatura establecida durante más de 15 minutos Nota No se recomienda utilizar el modo Au...

Страница 22: ... y la posición inferior para CALEFACCIÓN Si la posición inferior está seleccionada durante los modos REFRIGERACIÓN DESHUMIDIFICACIÓN el deflector se desplaza automáticamente a la posición hacia arriba 3 pasado un período de 30 minutos a 1 hora para evitar que gotee el agua de condensación Oscilación El deflector asciende y desciende de forma intermitente OSCILACIÓN Dirección del flujo de aire a izq...

Страница 23: ...cionamiento en modo SMART SET SELECCIÓN INTELIGENTE la temperatura mínima es de 50 F 10 C Vuelva a pulsar para cancelar el funcionamiento SMART SET SELECCIÓN INTELIGENTE El funcionamiento SMART SET SELECCIÓN INTELIGENTE tam bién se cancela al pulsar el botón MODE MODO Mediante una sencilla función de selección previa se puede recordar la confi guración preferida preestablecida con sólo pulsar el bo...

Страница 24: ...El funcionamiento POWERFUL potente también se cancela de forma auto mática en 15 minutos o al pulsar el botón ON OFF FAN ventilador ECONO COOL desconexión automática NATURAL FLOW flujo natural o i save FUNCIONAMIENTOPOWERFUL POTENTE 1 Pulse u durante el funcionamiento para ajustar el temporizador temporizador ACTIVADO El equipo se ACTIVARÁ a la hora ajustada temporizador DESACTIVADO El equipo se D...

Страница 25: ...a semana cuya configuración está completa Vuelva a pulsar para la DESACTIVACIÓN del temporizador semanal se apaga Nota Las configuraciones guardadas no se borrarán al DESACTIVAR el temporizador semanal Comprobación de la configuración del temporizador semanal 1 Pulse para entrar en el modo de configuración del temporizador semanal parpadea 2 Pulse o para ver la configuración de un día o número concret...

Страница 26: ...iltro de limpieza de aire Filtro de enzimas antialérgico elec trostático azul Cada 3 meses Elimine la suciedad con un aspirador Si la suciedad no se puede eliminar con un aspirador Sumerja el filtro y su carcasa en agua templada antes de enjuagarlos Después de lavarlo déjelo secar completamente a la sombra Instale todas las pestañas del filtro de aire Cada año Cambie el filtro de aire por uno nuevo p...

Страница 27: ...gurado el temporizador los ajustes se anulan y la unidad empieza a funcionar al volver a encenderla Si no desea utilizar esta función póngase en contacto con el servicio técnico ya que tendrá que modificar los ajustes de la unidad Temperatura fijada 75 F 24 C Velocidad del ventilador Media Deflector horizontal Auto REFRIGERACIÓN de emergencia CALEFACCIÓN de emergencia Parada Nota Los primeros 30 minu...

Страница 28: ...l modo de calefacción el agua se condensa en el intercambiador de calor y empieza a gotear En el modo de calefacción la función de desescar chado derrite el hielo adherido a la unidad exterior y el agua empieza a gotear Sale humo blanco de la unidad exterior En el modo de calefacción el vapor que se genera debido al funcionamiento de desescarchado tiene el aspecto de humo blanco Controlador remoto...

Страница 29: ...ire de las unidades interior exterior 3 Compruebe que el cable de tierra esté conectado correctamente 4 Consulte la sección PREPARACIÓN ANTES DE LA PUESTA EN MARCHA y siga las instrucciones Página 4 CUANDOELACONDICIONADORDEAIRENOSE VAYAAUTILIZARDURANTEMUCHOTIEMPO Interior Exterior Refrigeración Margen superior 90 F 32 2 C DB 73 F 22 8 C WB 115 F 46 1 C DB Margen inferior 67 F 19 4 C DB 57 F 13 9 C...

Страница 30: ...nc impérativement être respectées Après avoir lu cette notice conservez la avec le manuel d installation à portée de main pour pouvoir la consulter aisément Veillez à recevoir une carte de garantie de votre revendeur et vérifi ez que la date d achat et le nom du magasin etc sont saisis correctement Symboles et leur signification AVERTISSEMENT toute manipulation incorrecte peut avoir des consé quence...

Страница 31: ...tilée Une ventilation insuffisante pourrait provoquer un manque d oxygène dans la pièce Couper le disjoncteur par temps d orage La foudre pourrait endommager le climatiseur Si le climatiseur a été utilisé pendant plusieurs saisons consécutives procéder à une inspection et à un entretien rigoureux en plus du nettoyage normal Une accumulation de saletés ou de poussière à l intérieur du climatiseur pe...

Страница 32: ... fonc tionnement affichage rétroéclairé Touche de refroidissement économique ECONO COOL Page 8 Touche de puissance POWERFUL Page 9 Touche MODE SMART SET RE GLAGE INTELLI GENT Page 8 Touche NATU RAL FLOW Page 9 Touche SEN SOR i see Page 5 Couvercle Faites glisser le cou vercle vers le bas pour ouvrir la télécommande Abaissez le davan tage pour accéder aux touches de la minuterie hebdomadaire Touche ...

Страница 33: ...strument fin Pour changer l unité de la température entre degrés Celsius C et degrés Fahrenheit F appuyez sur la touche RESET Avant la mise en marche insérez la fiche d alimentation électrique dans la prise secteur et ou enclenchez le disjoncteur Insertion des piles dans la télécommande 1 Retirez le couvercle avant 2 Insérez les piles alcalines AAA en plaçant d abord le pôle négatif 3 Posez le couve...

Страница 34: ...fonctionnement intermittent est un son normal produit par le dé placement du capteur i see d un côté à l autre 1 2 Appuyez sur la touche en mode REFROIDISSE MENT DÉSHUMIDIFICATION CHAUFFAGE et AUTO pour activer le contrôle i see Appuyez doucement à l aide d une pointe fine s éclaire Affichage du mode de fonctionnement Le réglage par défaut est actif Appuyez une nouvelle fois sur la touche pour ac ...

Страница 35: ...ant Éteint AUTO REFROIDISSEMENT DESHUMIDIFICATION CHAUFFAGE VENTILATION Mode AUTO permutation automatique Le climatiseur sélectionne le mode de fonctionnement selon la dif férence qui existe entre la température de la pièce et la température programmée En mode AUTO le climatiseur passe d un mode à l autre REFROIDISSEMENT CHAUFFAGE lorsque la température de la pièce diffère de 4 F 2 C environ par r...

Страница 36: ... mode de CHAUFFAGE En mode de REFROIDISSEMENT DESHUMIDIFICATION l ailette se place automatiquement en position vers le haut 3 au bout de 0 5 à 1 heure pour éviter la formation de gouttes de conden sation Oscillation L ailette monte et descend de façon intermittente OSCILLATION Vitesse du ventilateur Appuyez sur la touche pour sélectionner la direction horizontale du flux d air Chaque nouvelle press...

Страница 37: ...50 F 10 C Appuyez une nouvelle fois sur pour annuler le mode SMART SET REGLAGE INTELLIGENT Une pression sur la touche MODE permet également d annuler le mode SMART SET REGLAGE INTELLIGENT Remarque Il n est pas possible de programmer le mode de fonctionnement SMART SET sur la minuterie hebdomadaire Exemple d utilisation 1 Mode économie d énergie Réglez la température à 4 F 2 C ou 6 F 3 C de plus en...

Страница 38: ...z une nouvelle fois sur LA TOUCHE pour annuler le mode NATURAL FLOW Une pression sur les touches POWERFUL ou ECONO COOL permet également d annuler le fonctionnement en mode NATURAL FLOW Remarque Étant donné que la vitesse du ventilateur change en permanence en mode de fonctionnement NATURAL FLOW le bruit du flux d air la vitesse du déplace ment d air et la température du flux d air changent égalemen...

Страница 39: ... la semaine pour lequel le réglage est terminé s allume Appuyez à nouveau sur pour désactiver la minute rie hebdomadaire OFF s éteint Remarque Les réglages enregistrés ne sont pas effacés lorsque la minuterie hebdomadaire est désactivée Vérification du réglage de minuterie hebdomadaire 1 Appuyez sur pour passer en mode de réglage de la minuterie hebdomadaire clignote 2 Appuyez sur ou sur pour affic...

Страница 40: ...es du filtre à air Tous les ans Pour des performances optimales remplacer le filtre d épuration d air Référence MAC 2330FT E Tirez sur le panneau frontal pour le retirer du filtre à air Trou Charnière Filtre désodorisant noir Tous les 3 mois Éliminez la saleté avec un aspirateur ou immergez le filtre dans un réci pient d eau tiède 86 à 104 F 30 à 40 C pendant 15 minutes environ Rincez abondamment Aprè...

Страница 41: ...Si vous avez recours au fonctionnement manuel de la minuterie le réglage de la minuterie sera annulé et le climatiseur redémarrera au retour de l alimentation Si vous ne voulez pas utiliser cette fonction veuillez vous adresser au repré sentant du service technique afin qu il modifie le réglage du climatiseur Température programmée 75 F 24 C Vitesse du ventilateur moyenne Ailette horizontale auto RE...

Страница 42: ...de chauffage l eau de condensation présente sur l échangeur thermique peut goutter En mode de chauffage l opération de dégivrage fait fondre la glace présente sur l unité externe et celle ci se met à goutter De la fumée blanche sort de l unité externe En mode de chauffage la vapeur générée par l opération de dégivrage peut ressembler à de la fumée blanche Télécommande Aucun affichage sur la télécom...

Страница 43: ...ement de certains champignons tels que les moisissures 2 Appuyez sur pour arrêter le fonctionnement du climatiseur 3 Débranchez la fiche d alimentation électrique et ou coupez le disjoncteur 4 Retirez toutes les piles de la télécommande Lorsque le climatiseur doit être remis en service 1 Nettoyez le filtre à air Page 11 2 Veillez à ce que l entrée et la sortie d air des unités interne et externe ne ...

Страница 44: ... please visit us at http www metahvac com Be sure to have the model and serial number for each of your indoor and outdoor units ready before starting the registration process If you need assistance registering your products call or write to us at Mitsubishi Electric Trane HVAC US LLC ATTN Customer Care Center 1340 Satellite Boulevard Suwanee GA 30024 Phone 1 800 433 4822 E mail CustomerCare hvac m...

Отзывы: