47
OPERATING PROCEDURE
PHOTOS
3. Removing the outdoor fan motor
(1) Remove the cabinet. (Refer to 1)
(2) Unconnect the connector remove the clamp of fan motor
lead wire.
(3) Remove the propeller nut and remove the propeller.
(4) Remove screws fixing the fan motor.
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover on the compressor.
(5) Disconnect lead wires from the glass terminal of the
compressor.
(6) Recover gas from the refrigerant circuit.
(7) Disconnect the welded part of the discharge pipe.
(8) Disconnect the welded part of the suction pipe.
(9) Remove nuts fixing the compressor.
(10) Remove the compressor.
NOTE
●
Before using a burner, recover gas from the pipes until the
pressure gauge shows 0 kg/cm
2
(0 MPa).
●
Use the burner under the condition that gas can be recovered
even when the inner pressure rises by heat.
Photo 5
Terminal cover
Compressor
Discharge
pipe
Suction
pipe
Compressor nuts
Photo 4
Fan motor cable
Connector
Propeller fan Propeller fan nut
Glass
terminal
OC282-A--2.qxp 03.1.28 4:30 PM Page 47