46
OPERATING PROCEDURE
PHOTOS
1. Removing the cabinet
(1) Remove the screws of the cabinet.
(2) Hold the bottom of the cabinet on the both side to remove
the cabinet.
2. Removing the electrical parts
(1) Remove the cabinet.(Refer to 1)
(2) Remove the following parts.
•Compressor capacitor(C1)
•Outdoor fan capacitor(C2)
•Terminal block(TB,TB2)
•Fan motor relay(X1)[For SU-2.5NR.TH, SU-2.5VR.TH and
SU-2.5VR.TH-T]
•Contactor(52C)
•Fuse(F)
SU-1.6NR.TH
SU-2NR.TH
SU-2.5NR.TH
SU-1.6VR.TH
SU-2VR.TH
SU-2.5VR.TH
SU-1.6VR.TH-T SU-2VR.TH-T SU-2.5VR.TH-T
Photo 1
Photo 3
Photo 2
Screws
Screws
Service
panel
Compressor
run capacitor
Compressor
Contactor
Terminal bed
Fuse
OC282-A--2.qxp 03.1.28 4:30 PM Page 46