![Mitsubishi Electric SU-1.6NR Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/mitsubishi-electric/su-1-6nr/su-1-6nr_technical-and-service-manual_1810031039.webp)
39
OPERATING PROCEDURE
PHOTOS
3. Removing the heat exchanger and the compressor
(1) Remove the rear panel (2 screws in front, 1 screw on
the side, 3 screws in the rear). Remove the valve bed,
and open the rear panel to the rear to remove.
NOTE :
All panels are fixed by catches, and must be removed by
shifting up and down.
(2) Remove the 4 screws of the right side panel and
remove it.
(3) Remove the 3 screws of the rear guard and remove it.
(4) Remove the 4 screws of the separator support plate
and remove it.
(5) Remove the 2 screws of the motor support and
remove it.
(6) Remove the 5 screws of the valve bed.
The valve bed is fixed by the catches on the right and
left sides.
Lift it to remove.
(7) Remove the electrical parts box.
Disconnect the connectors from the high pressure
switch, crank case heater, shell thermo, and fan motor
lead.
(8) Remove the 2 screws of the separator and remove it.
(9) Recover gas from the refrigerant circuit.
(10) Remove the 2 screws of the heat exchanger and
remove it.
Detach the welded point of pipe.
(11) Remove the 3 nuts of the compressor and remove it.
Detach the welded points of the compressor suction
pipe and discharge pipe.
NOTE
●
Before using a burner, recover gas from the pipes until
the pressure gauge shows 0 kg/cm
2
(0 MPa).
●
Use the burner under the condition that gas can be
recovered even when the inner pressure rises by heat.
Photo 4
Photo 5
Photo 6
Compressor
Ball valve
Charge plug
Heat exchanger
Accumulator
Screws
Screws
OC282-A--2.qxp 03.1.28 4:30 PM Page 39