5
-
Item
Model
SRK25CIS
SRC25CIS
Cooling capacity
(1)
W
7000
Power source
1 Phase, 220V, 50Hz
Cooling input
kW
2.04
Running current (Cooling)
A
10.2
Inrush current
A
45
COP
Cooling: 3.43
Noise level Cooling
Sound level
dB
Hi 46, Me 42, Lo 39
52
Power level
60
67
Exterior dimensions
Height
Width
Depth
mm
318 1098 248
750 880 340
Color
Yellowish white
Stucco white
Net weight
kg
15
67
Refrigerant equipment
Compressor type & Q’ty
–
2JS386D5CA02 (Rotary type) 1
Motor
kW
–
1.8
Starting method
–
Line starting
Heat exchanger
Slit fins & inner grooved tubing
Straight fin & inner grooved tubing
Refrigerant control
Capillary tubes + Electric expansion valve
Refrigerant
(3)
kg
R22 1.75 (Pre-charged up to the piping length of 7m)
Refrigerant oil
R
0.7 (ATMOS NM56M or SUNISO 4GDID)
Deice control
Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan 1
Propeller fan 1
Motor
W
46
85
Air flow (at High)
(Cooling)
CMM
20.5
60
Air filter, Q’ty
Polypropylene net (washable) 2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote control
–
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D
mm (in)
Liquid line: ø6.35 (1/4")
Gas line: ø15.88 (5/8")
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.70m
Gas line : 0.63m
–
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source supply
Terminal block (Screw fixing type)
Size Core number
1.5 mm
2
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter
⳯
1, Photocatalytic washable deodorizing filter
⳯
1)
Optional parts
Notes (1) The data are measured at the following conditions.
Model SRK25CIS (Indoor unit)
SRC25CIS (Outdoor unit)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
(2) The operation data are applied to the 220V.
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 7 to 25m, add 10g refrigerant per meter.
Operation data
(1) (2)
Refrig
erant
piping
Compressor: overheat protection, Frost protection, Serial signal error protection, Indoor fan motor error
protection
The piping length is 7.5m.
(220V)
⳯
⳯
⳯
⳯
⳯
⳯
⳯
⳯
⳯
⳯
⳯
⳯
Recommended breaker size
A
20
Содержание SRK19CIS
Страница 2: ... 1 TECHNICAL MANUAL ...
Страница 43: ... 42 MEMO ...
Страница 44: ... 43 PARTS LIST INDOOR UNIT SRK19CIS SRK25CIS OUTDOOR UNIT SRC19CIS SRC25CIS ...
Страница 45: ... 44 ...
Страница 46: ... 45 ...
Страница 47: ... 46 ...
Страница 48: ... 47 ...
Страница 49: ... 48 ...
Страница 50: ... 49 ...
Страница 51: ... 50 ...
Страница 52: ... 51 ...
Страница 53: ... 52 ...
Страница 54: ... 53 ...
Страница 55: ... 54 ...
Страница 56: ... 55 ...
Страница 57: ... 56 ...
Страница 58: ... 57 ...
Страница 59: ... 58 ...
Страница 60: ... 59 ...
Страница 61: ... 60 ...
Страница 62: ... 61 ...
Страница 63: ... 62 ...
Страница 64: ... 63 ...
Страница 65: ...ROOM AIR CONDITIONING TECHNICAL MANUAL PARTS LIST Manual No 09 SRK T 086 ...