2. Install The Panel
(1) Remove the inlet grid.
(2) Install the panel
(3) Hang the air-in grid to the panel, then connect the lead terminator of the swing motor
and that of the control box with corresponding terminators on the body respectively.
(4) Relocate the air-in grid in the procedure of reversed order, install the air-in grid.
CAUTIONS:
CAUTIONS
Never put the panel face down on floor or against the wall, or on bulgy objects.
Never crash or strike it.
a. Slide two grid switches toward the middle at the same time, and then pull them up. (Refer to
chart 9)
b. Draw the grid up to an angle of about 30 , and remove it. (Refer to chart 10)
o
a. Align the swing motor on the panel to the water receiver of the body properly. (Refer to chart 11)
b. Hang the four fixed rope of the main body to the installation cover and the other three covers of
the swing motor: (Refer to chart 11
and
)
c. Install the panel on the main body with bolt (M5
16) and washer. (Refer to chart 11
)
d. Adjust the four panel hook screws to keep the panel horizontal, and screw them up to the ceiling
evenly.
e. Regulate the panel in the direction of the arrow in Chart 11
slightly to fit the panel's center to
the center of the ceiling's opening. Guarantee that hooks of four corners are fixed well.
f. Keep fastening the screws under the panel hooks, until the thickness of the sponge between the
body and the panel's outlet has been reduced to about 4~6mm. The edge of the panel should
contact with the ceiling well. (Refer to chart 12)
Malfunction described in Chart 13 can be caused by inappropriate tightness the screw.
If the gap between the panel and ceiling still exists after fastening the screws, the height of the
indoor unit should be modified again. You can modify the height of the indoor unit through the
openings on the panel's four corners, if the lift of the indoor unit and the drainpipe is not
influenced (refer to chart 14-right).
1
2
4
3
The installation cover of the swing motor must sink into the corresponding water receiver.
..
..