Air Condition Link-Circuit
18000Btu/h type(1-phase)
For R22,cooling only
Chart 39
19
CAUTION:
Wrong wiring connections may cause some electrical parts to malfunction.
1. Remove the electric parts cover from the outdoor unit.
2. Connect the connective cables to the terminals as identified with their respective matched
numbers on the terminal block of indoor and outdoor units.
(Connective cable sheath length to be removed and insert into the terminal block.)
3. To prevent the ingress off water, from a loop of the connective cable as illustrated in the
installation diagram of indoor and outdoor units.
4. Insulate unused cords (conductors) with PVC-tape. Process them so they do not touch any
electrical or metal parts.
OUTDOOR UNIT
Cord wire
40mm
10mm
Chart 40
POWER:
220-240V~50Hz
Содержание Slim Four-Way Cassette Type