23
(2) OPERATION
Function
Cooling
Heating
"A" Cooling steady state
at rated compressor speed
"B-2" Cooling steady state
at rated compressor speed
"B-1" Cooling steady state
at minimum compressor speed
Low ambient cooling steady state
at minimum compressor speed
Intermediate cooling steady state
at intermediate compressor speed
Standard rating-heating
at rated compressor speed
Low temperature heating
at rated compressor speed
Max. temperature heating
at minimum compressor speed
High temperature heating
at minimum compressor speed
Frost accumulation
at rated compressor speed
Frost accumulation
at intermediate compressor speed
DB (°F)
80
80
80
80
80
70
70
70
70
70
70
WB (°F)
67
67
67
67
67
60
60
60
60
60
60
Indoor
DB (°F)
95
82
82
67
87
47
17
62
47
35
35
WB (°F)
(75)
(65)
(65)
(53.5)
(69)
43
15
56.5
43
33
33
Outdoor
Condition
Intake air
temperature
8-1. OPERATING RANGE
(1) POWER SUPPLY
Outdoor unit
Rating
208/230 V 60 Hz 1
Guaranteed Voltage
Model
Min. 198 V
Max. 253 V
208 V 230 V
MXZ-2B20NA
MXZ-3B24NA
MXZ-3B30NA
MXZ-4B36NA