B-15
PERFORMANCE DA
TA
Note:
Q : Total capacity (kW)
SHF : Sensible heat factor
D.B.: Dry-bulb temperature
SHC : Sensible heat capacity (kW)
INPUT : Total power input (W)
W.B.: Wet-bulb temperature
600
o
600
CEILING
CASSETTE
CEILING CASSETTE
S series
Note:
Q : Total capacity (kW)
SHF : Sensible heat factor
D.B.: Dry-bulb temperature
SHC : Sensible heat capacity (kW)
INPUT : Total power input (W)
W.B.: Wet-bulb temperature
OUTDOOR D.B.(
)
INDOOR INDOOR
35
40
46
D.B.(
) W.B.(
)
Q
SHC SHF INPUT
Q
SHC SHF INPUT
Q
SHC SHF INPUT
21
21
22
22
22
23
23
23
24
24
24
24
25
25
25
26
26
26
26
26
27
27
27
27
27
28
28
28
28
28
29
29
29
29
29
30
30
30
30
30
31
31
31
31
31
32
32
32
32
32
18
20
18
20
22
18
20
22
18
20
22
24
20
22
24
18
20
22
24
26
18
20
22
24
26
18
20
22
24
26
18
20
22
24
26
18
20
22
24
26
18
20
22
24
26
18
20
22
24
26
4.51
4.74
4.51
4.74
5.01
4.51
4.74
5.01
4.51
4.74
5.01
5.29
4.74
5.01
5.29
4.51
4.74
5.01
5.29
5.57
4.51
4.74
5.01
5.29
5.57
4.51
4.74
5.01
5.29
5.57
4.51
4.74
5.01
5.29
5.57
4.51
4.74
5.01
5.29
5.57
4.51
4.74
5.01
5.29
5.57
4.51
4.74
5.01
5.29
5.57
0.50
0.38
0.54
0.42
0.30
0.58
0.46
0.34
0.62
0.50
0.38
0.26
0.54
0.42
0.30
0.70
0.58
0.46
0.34
0.22
0.74
0.62
0.50
0.38
0.26
0.78
0.66
0.54
0.42
0.30
0.82
0.70
0.58
0.46
0.34
0.86
0.74
0.62
0.50
0.38
0.90
0.78
0.66
0.54
0.42
0.94
0.82
0.70
0.58
0.46
1597
1663
1597
1663
1728
1597
1663
1728
1597
1663
1728
1793
1663
1728
1793
1597
1663
1728
1793
1858
1597
1663
1728
1793
1858
1597
1663
1728
1793
1858
1597
1663
1728
1793
1858
1597
1663
1728
1793
1858
1597
1663
1728
1793
1858
1597
1663
1728
1793
1858
2.25
1.80
2.43
1.99
1.50
2.61
2.18
1.70
2.79
2.37
1.91
1.38
2.56
2.11
1.59
3.16
2.75
2.31
1.80
1.22
3.34
2.94
2.51
2.01
1.45
3.52
3.13
2.71
2.22
1.67
3.70
3.32
2.91
2.43
1.89
3.88
3.51
3.11
2.65
2.12
4.06
3.70
3.31
2.86
2.34
4.24
3.89
3.51
3.07
2.56
4.14
4.42
4.14
4.42
4.69
4.14
4.42
4.69
4.14
4.42
4.69
4.97
4.42
4.69
4.97
4.14
4.42
4.69
4.97
5.24
4.14
4.42
4.69
4.97
5.24
4.14
4.42
4.69
4.97
5.24
4.14
4.42
4.69
4.97
5.24
4.14
4.42
4.69
4.97
5.24
4.14
4.42
4.69
4.97
5.24
4.14
4.42
4.69
4.97
5.24
0.50
0.38
0.54
0.42
0.30
0.58
0.46
0.34
0.62
0.50
0.38
0.26
0.54
0.42
0.30
0.70
0.58
0.46
0.34
0.22
0.74
0.62
0.50
0.38
0.26
0.78
0.66
0.54
0.42
0.30
0.82
0.70
0.58
0.46
0.34
0.86
0.74
0.62
0.50
0.38
0.90
0.78
0.66
0.54
0.42
0.94
0.82
0.70
0.58
0.46
1695
1744
1695
1744
1826
1695
1744
1826
1695
1744
1826
1875
1744
1826
1875
1695
1744
1826
1875
1940
1695
1744
1826
1875
1940
1695
1744
1826
1875
1940
1695
1744
1826
1875
1940
1695
1744
1826
1875
1940
1695
1744
1826
1875
1940
1695
1744
1826
1875
1940
2.07
1.68
2.24
1.85
1.41
2.40
2.03
1.60
2.57
2.21
1.78
1.29
2.38
1.97
1.49
2.90
2.56
2.16
1.69
1.15
3.06
2.74
2.35
1.89
1.36
3.23
2.91
2.53
2.09
1.57
3.39
3.09
2.72
2.29
1.78
3.56
3.27
2.91
2.48
1.99
3.73
3.44
3.10
2.68
2.20
3.89
3.62
3.28
2.88
2.41
3.82
4.09
3.82
4.09
4.37
3.82
4.09
4.37
3.82
4.09
4.37
4.69
4.09
4.37
4.69
3.82
4.09
4.37
4.69
4.92
3.82
4.09
4.37
4.69
4.92
3.82
4.09
4.37
4.69
4.92
3.82
4.09
4.37
4.69
4.92
3.82
4.09
4.37
4.69
4.92
3.82
4.09
4.37
4.69
4.92
3.82
4.09
4.37
4.69
4.92
0.50
0.38
0.54
0.42
0.30
0.58
0.46
0.34
0.62
0.50
0.38
0.26
0.54
0.42
0.30
0.70
0.58
0.46
0.34
0.22
0.74
0.62
0.50
0.38
0.26
0.78
0.66
0.54
0.42
0.30
0.82
0.70
0.58
0.46
0.34
0.86
0.74
0.62
0.50
0.38
0.90
0.78
0.66
0.54
0.42
0.94
0.82
0.70
0.58
0.46
1760
1842
1760
1842
1891
1760
1842
1891
1760
1842
1891
1956
1842
1891
1956
1760
1842
1891
1956
2021
1760
1842
1891
1956
2021
1760
1842
1891
1956
2021
1760
1842
1891
1956
2021
1760
1842
1891
1956
2021
1760
1842
1891
1956
2021
1760
1842
1891
1956
2021
1.91
1.56
2.06
1.72
1.31
2.21
1.88
1.49
2.37
2.05
1.66
1.22
2.21
1.84
1.41
2.67
2.37
2.01
1.60
1.08
2.83
2.54
2.19
1.78
1.28
2.98
2.70
2.36
1.97
1.48
3.13
2.87
2.53
2.16
1.67
3.28
3.03
2.71
2.35
1.87
3.44
3.19
2.88
2.53
2.07
3.59
3.36
3.06
2.72
2.26
COOLING operation at Rated frequency
SLZ-KA50VA(L) / SUZ-KA50VA
CAPACITY : 4.6(kW) INPUT : 1630(W) SHF : 0.68