 WARNING

¡

 

Fasten the wiring to the terminal securely and hold the cable securely so as not to apply unexpected 

stress on the terminal.

Loose connection or hold will cause abnormal heat generation or fire.

¡

 

Make sure the power supply is turned off when electric wiring work.

Otherwise, electric shock, malfunction and improper running may occur.

 CAUTION

¡

 

DO NOT install the wireless kit at the following places in order to avoid malfunction.

(1)  Places exposed to direct sunlight

(2)  Places near heat devices

(3)  High humidity places

(4)  Hot surface or cold surface enough to gen-

erate condensation

(5)  Places exposed to oil mist or steam directly

(6)  Uneven surface

(7)  Places affected by the direct airflow of the 

AC unit.

(8)  Places  where  the  receiver  is  influenced  by 

the  fluorescent  lamp  (especially  inverter 

type) or sunlight.

(9)  Places  where  the  receiver  is  affected  by 

infrared  rays  of  any  other  communication 

devices

(10) Places where some object may obstruct the 

communication with the remote controller

¡

 

DO NOT leave the wireless kit without the cover.

In case the cover needs to be detached, protect the receiver with a packaging box or bag in order 

to keep it away from water and dust.

 

Note

¡

 

Instruct the customer how to operate it correctly referring to the instruction manual.

¡

 

For the installation method of the air conditioner itself, refer to the installation manual enclosed in the package.

OPTION PARTS

 

 Wireless kit

Содержание RCN-K-E

Страница 1: ...ed to oil mist or steam directly 6 Uneven surface 7 Places affected by the direct airflow of the AC unit 8 Places where the receiver is influenced by the fluorescent lamp especially inverter type or sunlight 9 Places where the receiver is affected by infrared rays of any other communication devices 10 Places where some object may obstruct the communication with the remote controller DO NOT leave t...

Страница 2: ...to operate it correctly referring to the instruction manual For the installation method of the air conditioner itself refer to the installation manual enclosed in the package DO NOT install it on the following places PHA012D038 Attention 1 Places exposed to direct sunlight 2 Places near heat devices 3 High humidity places 4 Hot surface or cold surface enough to generate condensation 5 Places expos...

Страница 3: ...e attached wiring assy B c Bundle wiring with attached ties d Install the interface PCB assy on the left cover of the indoor unit with the attached insulation Refer to below figure 1 In case of the piping routed from right side Put back Panel and stick Label on Panel Refer to 3 How to install the control assy Put back Panel and stick Label on page 362 Fixing base Fixing base Fix with insulation Fi...

Страница 4: ... the left FDK22 56 FDK71 Fix with insulation Fix with insulation Fixing base Fixing base Fix Wiring assy for X Y a Fix the terminal of the wiring assy for X Y on the terminal block of the indoor unit Non polarized b Route the wiring as shown in figure c Bundle wirings with attached ties 5 Install interface PCB assy on Indoor unit a Install the cover in which the interface PCB assy is installed 4 P...

Страница 5: ...nit bottom lid and fasten the fixing screw A only FDK22 56 1 Stick Label on Panel Stick the attached label on the front panel Label must be stuck under the left side LED of the front panel Label must be stuck under the right side LED of the front panel 2 1 2 1 2 Label and have 2 dots Matched the dot on the label and the bottom of the LED hole FDK22 56 FDK71 Label 1 Label 2 Put back Panel and stick...

Страница 6: ...When the batteries are removed the setting will return to the default setting Please make sure to reset it when the batteries are replaced Caution Instruct the customer to set the mentioned above when replacing the batteries How to set is also mentioned in the user s manual attached on the air conditioner Auto mode operation setting Radio prevention mode 2 Hot surface or cold surface enough to gen...

Страница 7: ...tions on the thickness and length of wire Maximum total extension 600m Standard Within 100m x 0 3mm2 Within 200m x 0 5mm2 Within 300m x 0 75mm2 Within 400m x 1 25mm2 Within 600m x 2 0mm2 1 2 3 1 2 60o 60o Top view 5m 5m Receivable range Receivable range 5m Standard signal receiving range Condition Illuminance at the receiver area 360 lux When no lighting fixture is located within 1m of indoor unit...

Страница 8: ...ioner is in operation it will stop the air conditioner After safety confirmation turn on the power Transmit a cooling operation command with the wireless remote controller while the backup switch on the receiver is depressed If the backup switch on the receiver is pressed during a test run it will end the test run If the air conditioner can not operate properly during the test run check wiring acc...

Страница 9: ...RC E3 Unit mm PHA001Z022 ...

Отзывы: