background image

-

 

2

 

-

FDK Series

· RCN-K-E (Models : FDK22~56)

· RCN-K71-E (Model : FDK71)

WARNING

CAUTION

Interface PCB has the following switches to 
set the function.
Default setting is shown with        mark.

1. Remove the upper case of interface PCB assy.
2. Change the switch setting on PCB.

Turn off the power source during servicing or inspection work.

If the power is supplied during servicing or inspection work, it could cause electric shock and injury by the operating fan.

Setting on site

To change setting

NOTE

When SW1-1 is turned to off position, change the wireless remote 
controller setting.
For the method of changing the setting, refer to

Setting to avoid

mixed communication

  on page 363.

WIRELESS KIT INSTALLATION MANUAL

Use specified wire for electrical wiring, fasten the wiring to the terminal securely, and hold the cable securely in order not to apply
unexpected stress on the terminal.

Loose connections or hold could result in abnormal heat generation or fire.

Shut off the power before electrical wiring work.

It could cause electric shock, unit failure and improper running.

DO NOT leave the wireless kit without the cover.

In case the cover needs to be detached, protect the receiver with a packaging box or bag in order to keep it away from water and dust.

• Instruct the customer how to operate it correctly referring to the instruction manual.
• For the installation method of the air conditioner itself, refer to the installation manual enclosed in the package.

DO NOT install it on the following places.

PHA012D038

Attention

(1) Places exposed to direct sunlight
(2) Places near heat devices
(3) High humidity places
(4) Hot surface or cold surface enough to generate condensation
(5) Places exposed to oil mist or steam directly

(6) Places where the receiver is influenced by the fluorescent lamp 

(especially inverter type) or sunlight.

(7) Places where the receiver is affected by infrared rays of any

other communication devices

(8) Places where some object may obstruct the communication with 

the remote controller

Preparation before installation

2

ON : Normal (1ch)

OFF : Customized (2ch)

Prevents interference

during plural setting

Receiver master/slave

setting

Buzzer valid/invalid

Auto restart

SW1-1

SW1-2

SW1-3

SW1-4

ON : Master

OFF : Slave

ON : Valid

OFF : Invalid

OFF : Invalid

Indication for error

Not in use

SW1-5

SW1-6

ON : Valid

OFF : Invalid

ON : – – –

OFF : – – –

1 2 3 4 5 6

ON
OFF

Receiver

Terminal

Interface PCB

upper case

Switch

Default settings

SW1

ON : Valid

1

2

How to install the control assy (Put back Panel and stick Label)

3

    Put back Panel

a) Always remove the air filter beforehand.
b) Place the front panel over the indoor unit.
c) Engage it onto the indoor unit by pressing the areas marked with      in the figure from the front.
d) Fasten the fixing screw B.
e) Set the air filter.
f ) Attach the indoor unit bottom lid and fasten the fixing screw A. (only FDK22-56)

1

    Stick Label on Panel

Stick the attached label on the front panel.
Label

must be stuck under the left side LED of the front panel.

Label

must be stuck under the right side LED of the front panel.

2

1
2

1

2

Label     and     have 2 dots.
Matched the dot on the label
and the bottom of the LED
hole.

<

FDK22-56

<

>

FDK71

>

<

Label

>

1

<

Label

>

2

Put back Panel and stick Label

Label

1

Label

2

Label

Unused

1

Label

2

Unused

Dot

Dot

4

Push

Push

Lid

Screw B

Screw B

Screw A

Hook

Hook

<

FDK71

>

<

FDK22-56

>

Fixing screw B

3

How to install the control assy (In case of the pipe routed through the right)

3

The control assy (Receiver and interface PCB assy) can be installed inside the indoor unit.
After turning off the power and confirming safety, execute as follows.

    Remove Panel

a) Remove the fixing screw A and detach the unit bottom lid.

(only FDK22-56)

b) Remove the fixing screw B.
c) Pull the lower part of the front panel off the unit toward you.

And then, push it up to detach its upper part from the 
indoor unit. (Disengage 3 hooks located on the top part.)

2

6

<

FDK22-56

>

<

FDK71

>

Add attached Wiring assy (A)

Change to attached Wiring assy (B)

Push

Push

Lid

Screw B

Screw B

Screw A

Hook

Hook

<

FDK71

>

<

FDK22-56

>

Fixing screw B

Left cover

    Preparation before installing Control assy

a) Disconnect the receiver from the interface PCB assy, and attach on  wiring assy (A).
b) Change the original wiring (for X, Y) to the attached wiring assy (B).
c) Bundle wiring with attached ties.
d) Install the interface PCB assy on the left cover of the indoor unit with the attached 

insulation. (Refer to below figure.)

1

In case of the piping routed from right side

    Put back Panel and stick Label on Panel

Refer to

3 How to install the control assy (Put back Panel and stick Label)

  on page 362.

Fixing base

Fixing base

Fix with insulation

Fix with insulation

How to install the control assy (In case of the pipe routed through the left)

3

    Remove Panel

a) Remove the fixing screw A and detach the unit bottom lid.

(only FDK22-56)

b) Remove the fixing screw B.
c) Pull the lower part of the front panel off the unit toward you.

And then, push it up to detach its upper part from the 
indoor unit. (Disengage 3 hooks located on the top part.)

2

Push

Push

Lid

Screw B

Screw B

Screw A

Hook

Hook

<

FDK71

>

<

FDK22-56

>

Fixing screw B

Right cover

    Preparation before installing Control assy

a) Install the interface PCB assy on the right cover of the indoor unit with the attached insulation.

1

In case of the pipe routed through the left

<

FDK22-56

<

>

FDK71

>

Fix with insulation

Fix with insulation

Fixing base

Fixing base

Accessories

Please make sure that you have all of the following accessories.

Remote controller

holder

AAA dry cell

battery(RO3)

Wood screw

for holder

Wireless remote

controller

1

2

2

1

1

1

1

1

1

Display label

Tie

1

3

Rubber

insulation

Wiring ASSY (B)

Wiring ASSY (A)

Control ASSY

Right side refrigerant piping draw out only

    Fix Wiring assy (for X, Y)

a) Fix the terminal of the wiring assy (for X, Y) on the terminal

block of the indoor unit. (Non-polarized)

b) Route the wiring as shown in figure.
c) Bundle wirings with attached ties.

5

    Install interface PCB assy on Indoor unit

a) Install the cover in which the interface PCB assy is installed.

4

    Put back Panel and stick Label on Panel

Refer to

3 How to install the control assy (Put back Panel and stick Label)

  on page 4.

6

<

FDK22-56

>

<

FDK71

>

    Install Receiver on Indoor unit

a) Hang the claw of the receiver lower side on 

the claw of the indoor unit. (2 places) 
And snap in the claw of the receiver upper 
side on the hole of the indoor unit. (2 places)

b) Fix the wiring on the clip of the indoor unit. (2 places)

3

Fix wiring (2 places)

Both side

    Fix Wiring assy (for X, Y)

a) Fix the terminal of the wiring assy (for X, Y) on the terminal

block of the indoor unit. (Non-polarized)

b) Route the wiring as shown in figure.
c) Bundle wirings with attached ties.

5

    Install Receiver on Indoor unit

a) Hang the claw of the receiver lower side on 

the claw of the indoor unit. (2 places) 
And snap in the claw of the receiver upper 
side on the hole of the indoor unit. (2 places)

b) Fix the wiring on the clip of the indoor unit. (2 places)

3

    Install interface PCB assy on Indoor unit

a) Route the Wiring assy (A) and (B) through the front of installation board.
b) Install the cover in which the interface PCB assy is installed.

4

<

FDK22-56

>

<

FDK71

>

Fix wiring (2 places)

Both side

Wall

Installation board

Wiring

Содержание RCN-K-E

Страница 1: ...ed to oil mist or steam directly 6 Uneven surface 7 Places affected by the direct airflow of the AC unit 8 Places where the receiver is influenced by the fluorescent lamp especially inverter type or sunlight 9 Places where the receiver is affected by infrared rays of any other communication devices 10 Places where some object may obstruct the communication with the remote controller DO NOT leave t...

Страница 2: ...to operate it correctly referring to the instruction manual For the installation method of the air conditioner itself refer to the installation manual enclosed in the package DO NOT install it on the following places PHA012D038 Attention 1 Places exposed to direct sunlight 2 Places near heat devices 3 High humidity places 4 Hot surface or cold surface enough to generate condensation 5 Places expos...

Страница 3: ...e attached wiring assy B c Bundle wiring with attached ties d Install the interface PCB assy on the left cover of the indoor unit with the attached insulation Refer to below figure 1 In case of the piping routed from right side Put back Panel and stick Label on Panel Refer to 3 How to install the control assy Put back Panel and stick Label on page 362 Fixing base Fixing base Fix with insulation Fi...

Страница 4: ... the left FDK22 56 FDK71 Fix with insulation Fix with insulation Fixing base Fixing base Fix Wiring assy for X Y a Fix the terminal of the wiring assy for X Y on the terminal block of the indoor unit Non polarized b Route the wiring as shown in figure c Bundle wirings with attached ties 5 Install interface PCB assy on Indoor unit a Install the cover in which the interface PCB assy is installed 4 P...

Страница 5: ...nit bottom lid and fasten the fixing screw A only FDK22 56 1 Stick Label on Panel Stick the attached label on the front panel Label must be stuck under the left side LED of the front panel Label must be stuck under the right side LED of the front panel 2 1 2 1 2 Label and have 2 dots Matched the dot on the label and the bottom of the LED hole FDK22 56 FDK71 Label 1 Label 2 Put back Panel and stick...

Страница 6: ...When the batteries are removed the setting will return to the default setting Please make sure to reset it when the batteries are replaced Caution Instruct the customer to set the mentioned above when replacing the batteries How to set is also mentioned in the user s manual attached on the air conditioner Auto mode operation setting Radio prevention mode 2 Hot surface or cold surface enough to gen...

Страница 7: ...tions on the thickness and length of wire Maximum total extension 600m Standard Within 100m x 0 3mm2 Within 200m x 0 5mm2 Within 300m x 0 75mm2 Within 400m x 1 25mm2 Within 600m x 2 0mm2 1 2 3 1 2 60o 60o Top view 5m 5m Receivable range Receivable range 5m Standard signal receiving range Condition Illuminance at the receiver area 360 lux When no lighting fixture is located within 1m of indoor unit...

Страница 8: ...ioner is in operation it will stop the air conditioner After safety confirmation turn on the power Transmit a cooling operation command with the wireless remote controller while the backup switch on the receiver is depressed If the backup switch on the receiver is pressed during a test run it will end the test run If the air conditioner can not operate properly during the test run check wiring acc...

Страница 9: ...RC E3 Unit mm PHA001Z022 ...

Отзывы: