(2) Program
Examples
Turns ON refresh command.
Reads the number of output points
of slave address 2 to D101.
Changes output to slave to 0 if
slave address 2 cannot communicate.
Writes analog output data to slave
address 2.
Explanation of devices
X0
: Module ready (ON when normal)
X5
: AS-i power failure (OFF when normal)
X6
: Normal operation active (OFF when in normal operation)
X7
: Configuration mode active (OFF except when in configuration mode)
D101
: Number of analog output points of slave address 2
D302.2
: ON when slave address 2 is ready for communication
D400, D401 : Analog output data to slave address 2
D4, D5
: Output of slave address 2 and automatically refreshed data