2 - 2 2 - 2
2 SYSTEM CONFIGURATION
MELSEC-Q
(4) Software packages for the Q64RD
Relation between the system containing the Q64RD and software package is
shown in the following table.
GX Developer or GX Works2 is necessary when the Q64RD is used.
Software version
GX Developer
GX Configurator-TI
1
2
GX Works2
Q00J/Q00/Q01CPU
Single CPU system
Version 7 or later
Version 1.10L or later
Refer to the GX
Works2 Version 1
Operating Manual
(Common).
Multiple CPU system
Version 8 or later
Q02/Q02H/Q06H/
Q12H/Q25HCPU
Single CPU system
Version 4 or later
Version 1.00A or later
Multiple CPU system
Version 6 or later
Q02PH/Q06PHCPU
Single CPU system
Version 8.68W or
later
Version 1.13P or later
Multiple CPU system
Q12PH/Q25PHCPU
Single CPU system
Version 7.10L or
later
Multiple CPU system
Q12PRH/
Q25PRHCPU
Redundant CPU
system
Version 8.45X or
later
Version 1.14Q or later
Q00UJ/Q00U/
Q01UCPU
Single CPU system
Version 8.76E or
later
Version 1.24AA or later
Multiple CPU system
Q02U/Q03UD/
Q04UDH/
Q06UDHCPU
Single CPU system
Version 8.48A or
later
Multiple CPU system
Q10UDH/
Q20UDHCPU
Single CPU system
Version 8.76E or
later
Multiple CPU system
Q13UDH/
Q26UDHCPU
Single CPU system
Version 8.62Q or
later
Multiple CPU system
Q03UDE/Q04UDEH/
Q06UDEH/Q13UDEH/
Q26UDEHCPU
Single CPU system
Version 8.68W or
later
Multiple CPU system
Q10UDEH/
Q20UDEHCPU
Single CPU system
Version 8.76E or
later
Multiple CPU system
CPU modules other
than the above
Single CPU system
Cannot be used
Cannot be used
Multiple CPU system
If installed in a MELSECNET/H remote
I/O station
Version 6 or later
Version 1.00A or later
1 The product of Version 1.14Q or earlier is not compatible with "normal mode - offset/gain setting
mode switching" and "OMC refresh data". Use the product of Version 1.15R or later.
2 The product of Version 1.20W or earlier is not compatible with "Moving average", "Primary delay
filter" and "Conversion setting for disconnection detection function". Use the product of Version
1.21X or later.
2
Содержание Q64RD
Страница 2: ......
Страница 99: ...5 17 5 17 5 UTILITY PACKAGE GX Configurator TI MELSEC Q X Y Monitor Test 1 OMC refresh ...
Страница 108: ...6 3 6 3 6 PROGRAMMING MELSEC Q 2 Program example 6 1 2 Program example used when utility package is not used ...
Страница 113: ...6 8 6 8 6 PROGRAMMING MELSEC Q 2 Program example ...
Страница 114: ...6 9 6 9 6 PROGRAMMING MELSEC Q ...
Страница 178: ...App 19 App 19 APPENDICES MELSEC Q Appendix 3 External Dimension Diagram 1 Q64RD Q64RD G Unit mm ...
Страница 181: ...WARRANTY ...