PWFY-4
PWFY-P-NMU-E-BU/PWFY-P-NMU-E-AU (Sept. 2010)
PWF
Y-P-N
MU-E-BU
PWF
Y-P-N
MU-E-AU
2. SPECIFICATIONS
Model
Power source
kW
*1
Heating capacity
kcal / h
BTU / h
kW
A
W.B
*1
(Nominal)
*1
Power input
Current input
Outdoor temp.
Temp. range of
W.B
-
heating
Inlet Water temp.
kW
*2
Cooling capacity
kcal / h
BTU / h
kW
A
D.B
*2
(Nominal)
*2
Power input
Current input
Outdoor temp.
Temp. range of cooling
D.B
-
Inlet Water temp.
Total capacity
Model / Quantity
Connectable
outdoor unit
Sound pressure level (measured in anechoic room)
dB<A>
in.(mm)
in.(mm)
Diameter of
refrigerant pipe
in.(mm)
in.(mm)
Diameter of
water pipe
in.(mm)
mm
Field drain pipe size
External finish
External dimension H × W × D
in.
lbs(kg)
Net weight
Circulating water
Range
Design pressure
Water
R410A
Drawing
Standard attachment
Optional parts
Remark
Note:
*2 Nominal cooling conditions
*1 Nominal heating conditions
Outdoor Temp. : 47°FDB/43°FWB (8.3°CDB / 6.1°CWB)
Outdoor Temp. : 95°FDB (35°CDB
)
Pipe length : 7.6 m (25 ft)
Pipe length : 7.6 m (25 ft)
Level difference : 0m (0ft)
Level difference : 0m (0ft)
Inlet water Temp 86°F (30°C)
Water flow rate 2.15m
3
/h (555G/h)
Inlet water Temp 149°F (23°C)
Water flow rate 1.93m
3
/h (498G/h)
* Install the unit in an environment where the
* Due to continuing improvement, the above specifications may be subject to change without notice.
wet bulb Temp. will not exceed 92°F (32°C)
* The unit is not designed for outside installations.
* Please don't use steel for the water piping material.
* The water circuit must use the closed circuit.
* Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 32°F (0°C) or less.
Inlet
Outlet
Operation Volume
Liquid
Gas
Accessory
External
Wiring
Document
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
Unit converter
36,200
50~95°F (10~35°C)
0.015
Φ5/8 (Φ15.88) Brazed
Φ3/8 (Φ9.52) Brazed
PT3/4 (27.2) Screw
Installation Manual, Instruction Book
PT3/4 (27.2) Screw
NO
WKB94T461
0.072 - 0.065
50~100% of outdoor unit capacity
PUHY-P*T(S)HMU/P*Y(S)HMU-A(-BS)
PUHY-P*T(S)JMU/P*Y(S)JMU-A(-BS)
PQHY-P*T(S)HMU/P*Y(S)HMU-A(-BS)
23~109°F (-5~43°C) PURY - series
23~109°F (-5~43°C) PUHY - series
0.6~2.15
2.6~9.2
4.15
145
10~35
156~555
1.00
Strainer, Heat insulation material, 2 × Connector sets , 2 × Washer
Φ1-1/4 (Φ32)
PWFY-P36NMU-E-AU
1-phase 208 - 230 V 60Hz
9,100
10.6
29
11.7
800 (785 without legs) × 450 × 300
KE94C345
601
NONE
10,100
39,900
-4~60°F (-20~15.5°C) PUHY - series
50~105°F (10~41°C)
0.015
0.072 - 0.065
-4~90°F (-20~32°C) PURY - series
31-1/2" (30-15/16" without legs) × 17-3/4” × 11-13/16”
78 (35)
* Please do not use it as a drinking water. Discharge water from unit is not possible. Do not connect the output directly to a potable system.
* Please do not use groundwater and well water.
m
3
/h
G/h
G/min
L/min
MPa
psi
MPa
psi
kcal = kW x 860
BTU/h = kW x 3,412
cfm = m
3
/min x 35.31
G(us) = L × 0.2642
lbs
= kg / 0.4536
psi
= MPa×145.038
* The specification data is subject
to rounding variation.
PURY-P*T(S)HMU/Y(S)HMU-A(-BS)
PURY-P*T(S)JMU/P*Y(S)JMU-A(-BS)
PQRY-P*T(S)HMU/-P*Y(S)HMU-A(-BS)