RUNNING
WARNING!
TOTAL 11358KWh
OUTPUT 0W
MAXIMUM 4508W
If
WARNING! i
s displayed on the
LCD screen, touch and release
the [ENTER] button to display the
action to be taken
Touch and release
the [ENTER]
button once.
WARNING
PLEASE CLEAN
FILTER!
PLEASE CLEAN FILTER!
is
displayed on the LCD screen when
the internal temperature has risen.
Touch and release the [ENTER]
button to switch the display.
WARNING
NO DATE/TIME SET
PLEASE ENTER!
NO DATE/TIME SET
is
displayed on the LCD screen
when the present date and
time have not been set.
Touch and release the [ENTER]
button to display the setting
screen.
Ɣ
The internal temperature is rising. If dust has
accumulated in the exhaust openings and
air intake vent opening areas, see the daily
care items on p.56 6.1 to perform cleaning.
Ɣ
If the internal temperature drops, the
WARNING!
display is automatically
extinguished.
Touch and release
the [ENTER]
button once.
DATE/TIME
10 MAY 2011
21:58:00
SET
See p.48 5.4.2 Setting the
Date and Time, to perform
the setting.
If
ERROR E-42
is displayed on
the LCD screen, touch and
release the [ENTER] button to
switch the display.
Blinking
Touch and release
the [ENTER]
button once.
Action to take when WARNING is displayed
WARNING! is displayed in the following situations.
Ɣ
The internal temperature has risen.
Ɣ
The present date and time are not set.
If ERROR E-42 is displayed
Ɣ
The insulation resistance of the PV modules has dropped.
Ɣ
ERROR E-42
is cleared automatically when the insulation resistance returns to normal. If the insulation resistance does
not return to normal, contact the sales office from which the PV inverter was purchased for advice.
LOW INPUT POWER
ERROR E-42
TOTAL 11358kWh
OUTPUT 0W
MAXIMUM 4508W
ERROR E-42
INSULATION
RESISTANCE
IS NOT ENOUGH .
Touch and release
the [ENTER]
button once.
Touch and release
the [ENTER]
button once.