Model:
PUMY
-P36NHMU (-BS) – DIMENSIONS
PUMY-P36NHMU(-BS)_200802
b
© MITSUBISHI ELECTRIC
Certificate Number FM33568
Certificate Number EC97J1227
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired ISO
9001 certification under Series 9000 of the International Standard Organization (ISO)
based on a review of quality warranties for the production of refrigeration and air
conditioning equipment.
ISO Authorization System
The ISO 9000 series is a plant authorization system relating to quality warranties as
stipulated by the ISO. ISO 9001 certifies quality warranties based on the "design,
development, production, installation and auxiliary services" for products built at
an authorized plant.
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmental
management system standard ISO 14001 certification.
The ISO 14000 series is a set of standards applying to environmental protection set by the
International Standard Organization (ISO).
Min.500mm <19-11/16>
Min.500mm
<19-11/16>
Min.150mm
<5-29/32>
Min.10mm<3/8>
Handle
Side Air Intake
Front piping cover
Rear piping cover
Air intake
Rear Air Intake
Handle
Service panel
Handle
31<1-7/32>
74<2-19/32>
40<1-9/16>
Max.
30mm<1-3/16>
The diagram below shows
a
basic example.
See the installation manuals for details
.
Space needed for service access is shown in the diagram below.
<Foundation bolt height>
Please firmly secure the unit
using 4 foundation (M10<W3/8>)
bolts.(Bolts and washers must
be purchased separately.)
Air Discharge
Rear Air Intake
Side Air Intake
1
……Refrigerant GAS pipe connction (FLARE)
15.88 (5/8 inch)
2
……Refrigerant LIQUID pipe connection (FLARE)
9.52 (3/8 inch)
w
1…..Indication of STOP VALVE connection location.
Example of Notes
Piping Knockout Hole Details
1 CLEARANCE SPACE
2 SERVICE SPACE
3 FOUNDATION BOLTS
4 PIPING-WIRING DIRECTIONS
Piping and wiring connections
can be made using one of four locations on the unit: front, right, back, and bottom.
1/2 Conduit attachment
2-ø22<7/8>
When installing the conduit, set the attachment to the inside of each panel.
mm<inch>
FOUNDATION
Service space
Min.1000mm<39-3/8>
Min.10mm<3/8>
Min.10mm<3/8>
FREE
Min.150mm<5-29/32>
45<1-25/32>
40<1-9/16>
65<2-9/16>
92<3-5/8>
27<1-1/16>
55<2-3/16>
23<29/32>
73<2-7/8>
63<2-1/2>
Back piping hole
(Knockout)
Rear trunking hole
(Knockout)
Conduit hole
(2-n27<1-1/16>Knockout)
n92 <3-5/8>
n92 <3-5
/8>
19<3/4>
55<2-3/16>
92<3-5/8>
40<1-9/16>
73<2-7/8>
63<2-1/2>
23<29/32>
27<1-1/16>
92<3-5/8>
Right trunking hole
(Knockout)
Conduit hole
(2-n27<1-1/16>Knockout)
75
<2-31/32>
Right piping hole
(Knockout)
45<1-25/32>
40<1-9/16>
55<2-3/16>
73<2-7/8>
27<1-1/16>
23<29/32>
65<2-9/16>
92<3-5/8>
Conduit hole
(2-n27<1-1/16>Knockout)
Front trunking hole
(Knockout)
Front piping hole
(Knockout)
63
<2-1/2>
n92
<3-5
/8>
30<1-3/16>
81<3-3/16>
219<8-5/8>
71<2-13/16>
71<2-13/16>
Bottom piping hole
(Knockout)
Drain hole
5-n33<1-5/16>
220
<8-21/32>
145
<5-23/32>
145
<5-23/32>
145
<5-23/32>
Handle
600<23-5/8>
28<1-3/32>
370<14-9/16>
70<2-3/4>
56<2-7/32>
42<1-21/32>
56<2-7/32>
37<1-15/32>
19<3/4>
53<2-3/32>
417<16-13/32>
330<13>
175
<6-7/8>
175
<6-7/8>
2-12
o
36 Oval hole
(Foundation Bolt M10<W3/8>)
2-U Shaped notched hole
(Foundation Bolt M10<W3/8>)
30<1-3/16>
1088<42-27/32>
322<12-11/16>
635<25>
371<14-19/32>
950<37-13/32>
23<29/32>
1350<53-5/32>
w
1 423<16-21/32>
w
1 507<19-31/32>
Handle
1
2
( )
Left ……
For the power supply
Center …
For the transmission line
Right……
For concentration control
Terminal block
Ground for the transmission line
Ground for concentration control
Ground for the power supply
("GR"marking position)
Ø
Ø