Model:

 

PUMY

-P36NHMU (-BS) – DIMENSIONS

PUMY-P36NHMU(-BS)_200802

b

   © MITSUBISHI ELECTRIC

Certificate Number FM33568

Certificate Number EC97J1227

Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired ISO 

9001 certification under Series 9000 of the International Standard Organization (ISO) 

based on a review of quality warranties for the production of refrigeration and air 

conditioning equipment.

ISO Authorization System

The ISO 9000 series is a plant authorization system relating to quality warranties as 

stipulated by the ISO. ISO 9001 certifies quality warranties based on the "design, 

development, production, installation and auxiliary services" for products built at 

an authorized plant.

Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmental

management system standard ISO 14001 certification.

The ISO 14000 series is a set of standards applying to environmental protection set by the 

International Standard Organization (ISO). 

Min.500mm <19-11/16>

Min.500mm

<19-11/16>

Min.150mm

<5-29/32>

Min.10mm<3/8>

Handle

Side Air Intake

Front piping cover

Rear piping cover

Air intake

Rear Air Intake

Handle

Service panel

Handle

31<1-7/32>

74<2-19/32>

40<1-9/16>

   Max.

30mm<1-3/16>

The diagram below shows 

a

basic example.

See the installation manuals for details

.

Space needed for service access is shown in the diagram below.

<Foundation bolt height>

Please firmly secure the unit

using 4 foundation (M10<W3/8>) 

bolts.(Bolts and washers must

be purchased separately.)

Air Discharge

Rear Air Intake

Side Air Intake

1

……Refrigerant GAS pipe connction (FLARE)

15.88 (5/8 inch)

2

……Refrigerant LIQUID pipe connection (FLARE)

9.52 (3/8 inch)

w

1…..Indication of STOP VALVE connection location.

Example of Notes

Piping Knockout Hole Details

1 CLEARANCE SPACE

2 SERVICE SPACE

3 FOUNDATION BOLTS

4 PIPING-WIRING DIRECTIONS

Piping and wiring connections

can be made using one of four locations on the unit: front, right, back, and bottom.

1/2 Conduit attachment

2-ø22<7/8>

When installing the conduit,  set the attachment to the  inside of each panel.

mm<inch>

FOUNDATION

Service space

Min.1000mm<39-3/8>

Min.10mm<3/8>

Min.10mm<3/8>

FREE

Min.150mm<5-29/32>

45<1-25/32>

40<1-9/16>

65<2-9/16>

92<3-5/8>

27<1-1/16>

55<2-3/16>

23<29/32>

73<2-7/8>

63<2-1/2>

Back piping hole

(Knockout)

Rear trunking hole

(Knockout)

Conduit hole

(2-n27<1-1/16>Knockout)

n92 <3-5/8>

n92 <3-5

/8>

19<3/4>

55<2-3/16>

92<3-5/8>

40<1-9/16>

73<2-7/8>

63<2-1/2>

23<29/32>

27<1-1/16>

92<3-5/8>

Right trunking hole

(Knockout)

Conduit hole

(2-n27<1-1/16>Knockout)

   75

<2-31/32>

Right piping hole

(Knockout)

45<1-25/32>

40<1-9/16>

55<2-3/16>

73<2-7/8>

27<1-1/16>

23<29/32>

65<2-9/16>

92<3-5/8>

Conduit hole

(2-n27<1-1/16>Knockout)

Front trunking hole

(Knockout)

Front piping hole

(Knockout)

   63

<2-1/2>

n92

<3-5

/8>

30<1-3/16>

81<3-3/16>

219<8-5/8>

71<2-13/16>

71<2-13/16>

Bottom piping hole

(Knockout)

Drain hole

5-n33<1-5/16>

   220

<8-21/32>

   145

<5-23/32>

   145

<5-23/32>

   145

<5-23/32>

Handle

600<23-5/8>

28<1-3/32>

370<14-9/16>

70<2-3/4>

56<2-7/32>

42<1-21/32>

56<2-7/32>

37<1-15/32>

19<3/4>

53<2-3/32>

417<16-13/32>

330<13>

  175

<6-7/8>

  175

<6-7/8>

2-12

o

36 Oval hole

(Foundation Bolt M10<W3/8>)

2-U Shaped notched hole

(Foundation Bolt M10<W3/8>)

30<1-3/16>

1088<42-27/32>

322<12-11/16>

635<25>

371<14-19/32>

950<37-13/32>

23<29/32>

1350<53-5/32>

w

1 423<16-21/32>

w

1 507<19-31/32>

Handle

1

2

(              )

Left ……

For the power supply

Center …

For the transmission line

Right……

For concentration control

Terminal block

Ground for the transmission line

Ground for concentration control

Ground for the power supply

("GR"marking position)

Ø

Ø