background image

Job Name: 

Drawing Reference: 

Schedule No.

System No.: 

Notes:

OUTDOOR VRF SYSTEM 

SPECIFICATIONS

Capacity

Cooling……………………………………………..36,000 Btu/h

Heating……………………………………………..40,000 Btu/h

Power

Power Source……………….........208 / 230V, 1-phase, 60Hz

Power Input

  Cooling………………………………………………3.22 kW

  Heating………………………………………………2.93 kW

Current

  Cooling (208 / 230)........................................14.2 / 15.7 A

  Heating (208 / 230) ...................................…12.9 / 14.2 A

Minimum Circuit Ampacity (MCA) (208 / 230)….……..…26 A

Breaker Size for Wiring ........................................….......30 A

External Finish

………Pre-coated Galvanized-steel Sheets

Munsell No. 3Y 7.8 / 1.1

External Dimensions

Inches………………..53-3/16 h x 37-7/16 w x 13 (+1-3/16) d

mm……………………………..1,350 h x 950 w x 330 (+30) d

Net Weight

………………………………….287 lbs. / 130 kg

Fan

Type x Quantity...………..............................Propeller Fan x 2

Airflow Rate

……………………………………...……3,530 cfm

Motor Output……...…..………………………0.086 + 0.086 kW

Compressor

Type………………...................………….Inverter-driven Scroll

Motor Output………..…………………………………….2.2 kW

Lubricant

………………..…...………………………….FV50S

Refrigerant

……………..…...…………………………..R410A

Protection Devices

High Pressure Protection………………High Pressure Switch

Compressor…………Discharge Thermo / Overcurrent Detection

Fan…...…………………………..Overheat / Voltage Protection

Piping Diameter

Liquid (High Pressure)………..……………3/8" / 9.52 mm Flare

Gas (Low Pressure)………………………5/8" / 15.88 mm Flare 

Indoor Unit

Total Capacity…..…….50% –130% of Outdoor Unit Capacity

Model / Quantity…………………..…………..….P06-P36 / 1 ~ 6

Sound Level (Cooling / Heating)

………….49 / 51 dB(A) 

Operating Temperature Range

Cooling (Outdoor)……………….23°F ~ 115°F (-5° ~ +46°C) DB*

Heating (Outdoor)…………….0°F ~ +60°F (-18° ~ +15°C) WB

Anti-corrosion Protection

 

Blue Fin Treatment

 applied to condenser coil protects coil 

from airborne contaminants. 

Seacoast Protection

 

External Panel Base: Steel sheets with aluminum-zinc- 

   magnesium coating on external and internal surfaces

External Panel (Top, Front, Back): Galvanized steel sheets 

   with acrylic- and polyester-resin coating on external and  

   internal surfaces

Fan Motor Support: Galvanized-steel sheets with epoxy- 

   resin coating applied to external surface

Separator and Valve Bed: Galvanized-steel sheets with 

   epoxy-resin coating

Options

 Branch Joint (T-Branch)…………………..…....CMY-Y62-G-E

 Header - Four-Branch…………………………….CMY-Y64-G-E

 Header - Eight-Branch……………………………..CMY-Y68-G-E

 Drain Pan………………………………….….….PAC-SG64DP-E

 Drain Socket………………………………….….PAC-SG61DS-E

Model:

 PUMY-P36NHMU (-BS)

OUTDOOR VRF  

SYSTEM FEATURES

 ti

n

u

 r

o

o

d

t

u

o

 

e

s

a

h

p

-

e

l

g

n

i

S

 

   with variable refrigerant  

   flow (VRF)   

   technology

• In

verter-driven (variable 

   speed) compressor

• 

Total refrigerant piping 

   length of 394' (120 m)

• Uses CITY MU

L

TI indoo

r  

   units and Controls Net

work

Отзывы: