63
PKA-RP50FAL2 PKA-RP60FAL
PKA-RP71FAL
PKA-RP100FAL
INTAKE
CN20
(RED)
LIQUID
CN21
(WHT)
PIPE
CN29
(BLK)
1 2
1 2
1 2
1 3
1 3
1 3
1 2
TH5
TH1
TH2
REMOCON
CN22
(BLU)
1 2
2
1
TB5
R.B
TB6
2
1
TRANSMISSION WIRES DC12V
SWE
ON
OFF
SW2
SW1
LED3 LED2 LED1
ZNR
FUSE
X4
CN41
CN2L
CN51
CN32
WIRELESS
CN90
(WHT)
VANE
CN6V
(GRN)
MV
6
W.B
BZ
CNB
RECEIVER
RU
LED1 LED2 SW2 SW1
9
FAN
(WHT)
1 3 5
1
1
2
1
2
3
2 3
BLK
WHT
WHT
RED
RED
C
MF
X4
BCR
TO
OUTDOOR
UNIT
TB4
S1
S2
S3
YLW
ORN
ORN
BRN
YLW
ORN
BLK
WHT
P.B
I.B
Please set the voltage
using the remote controller.
For the setting method,
please refer to the indoor
unit Installation Manual
SW1
Table 1
Service board
SW2
Table 2
Service board
Service board
Service board
POWER
CNDK
(RED)
CNDK
(RED)
DC13.1V
CN2S
(WHT)
POWER
CND
(ORN)
POWER
CN2D(WHT)
INDOOR/OUTDOOR
COMMUNICATION
CN3C(BLU)
3
1
3
1
POWER
CND
(ORN)
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
TB2
TB4
POWER
SUPPLY
(1PHASE)
230V 50Hz
RED
BLU
YLW
ORN
ORN
BRN
TO
OUTDOOR
UNIT
L
S1
S2
S3
N
I.B
YLW
ORN
w
1 (Fig.1)
Refer to tables 1
and 2 for service PCB.
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
MODELS
PKA-RP50FAL2
PKA-RP60FAL
PKH-P60FALH
1 2 3 4 5
ON
OFF
MODELS
PKA-RP71FAL
PKH-P71FALH
1 2 3 4 5
ON
OFF
MODELS
PKA-RP100FAL
PKH-P100FALH
TB2
I.B
HEATER
CN24
(YLW)
PKH-P60 P100FALH models only
POWER SUPPLY
(1PHASE)
230V 50Hz
88H
FS2
26H
H1
L
RED
RED 5
3
RED
BLU
GRN/YLW
WHT
RED
6
1
RED
GRY
N
2
1
2
6
5
1
FS1
88H
YLW
YLW
GRN/YLW
P.B
INDOOR POWER BOARD
SYMBOL
NAME
[LEGEND]
I.B
INDOOR CONTROLLER BOARD
FUSE FUSE(T6.3AL250V)
ZNR
VARISTOR
CN2L CONNECTOR(LOSSNAY)
CN32 CONNECTOR(REMOTE SWITCH)
CN41 CONNECTOR(HA TERMINAL-A)
CN51 CONNECTOR(CENTRALLY CONTROL)
SW1
SWITCH (MODEL SELECTION)
w
See Table 1.
SW2
SWITCH (CAPACITY CODE)
w
See Table 2.
SWE
SWITCH(EMERGENCY OPERATION)
X4
RELAY(FAN MOTOR)
BCR
POWER SUPPLY(R.B)
LED1 POWER SUPPLY(I.B)
LED2
TRANSMISSION(INDOOR-OUTDOOR)
LED3
FAN CONTROL ELEMENT
C
CAPACITOR(FAN MOTOR)
FAN MOTOR
VANE MOTOR
MF
MV
SYMBOL
NAME
TB4
TERMINAL BLOCK(INDOOR/OUTDOOR
TB2
TERMINAL BLOCK (HEATER)
w
PKH-P.FALH
models only or option for PKA-RP.FAL models.
CONNECTING LINE)
TERMINAL BLOCK(REMOTE CONTROLLER
TRANSMISSION LINE )(OPTION)
ROOM TEMP.THERMISTOR
(0
;
/15k
'
, 25
;
/5.4k
'
DETECT)
PIPE TEMP.THERMISTOR/LIQUID
(0
;
/15k
'
, 25
;
/5.4k
'
DETECT)
COND./EVA.TEMP.THERMISTOR
(0
;
/15k
'
, 25
;
/5.4k
'
DETECT)
TB5
TH5
TH1
TH2
W.B
WIRELESS REMOTE CONTROLLER BOARD
RECEIVING UNIT
BUZZER
LED(RUN INDICATOR )
LED(HOT ADJUST)
SWITCH(HEATING ON/OFF)
SWITCH(COOLING ON/OFF)
WIRED REMOTE CONTROLLER BOARD(OPTION)
TERMINAL BLOCK(REMOTE CONTROLLER
THERMAL FUSE(117
;
10A:60,71FALH/
117
;
16A:100FALH)
TRANSMISSION LINE)
R.B
HEATER
RU
BZ
LED1
LED2
SW1
SW2
NAME
SYMBOL
HEATER
H1
HEATER THERMAL SWITCH
26H
HEATER CONTACTOR
88H
TB6
FS1,2
Notes:
1. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).
2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers (S1, S2, S3) for correct wirings.
3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing.
4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of 230V), adopting superimposed system of
power and signal.
w
1: When supplying power separately to indoor and outdoor units, refer to Fig 1.
w
2: For power supply system of this unit, refer to the caution label located near this diagram.
OCS05E-2.qxp 08.3.31 10:21 AM Page 63
Содержание PUHZ-RP100VHA3
Страница 52: ...52 WIRED REMOTE CONTROLLER Unit mm 130 120 19 43 5 ...
Страница 53: ...53 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Страница 98: ...98 9 3 PLA RP AA PLA RP AA2 9 3 1 Fresh air intake amount ...
Страница 99: ...99 9 3 2 BRANCH DUCT Installation at site ...
Страница 108: ...108 PEAD RP60GA PEAD RP71GA ...
Страница 109: ...109 PEAD RP100GA ...
Страница 116: ...116 ...