PEA-RP200, 250GA
OUTDOOR UNIT
CIRCUIT BREAKER
(FIELD SUPPLY)
PEA-RP200,250GA:15A
DSR
DSA
(3P)
(Hi)
C02
(6P)
(Lo)
C01
C01
5
4
TH5
TH2
TH1
INDOOR UNIT
POWER SUPPLY
3N~PE
380/400/415V
50Hz
BLACK
WHITE
RED
N
BLACK
WHITE
RED
TB2
L3
L2
L1
PE
52F
Hi
Lo
3
2
1
52F
1
2
3
MF1
TB6
LCD
REMOTE CONTROLLER
FB
TB4
S3
S2
S1
X6
X5
X4
3
75
1
FAN
ZNR
FUSE
4
123
SW2
OFF
ON
5
TAB1
3
1
CNSK
2
1
CN2S
DC
13.1V
CN2D
CN90
CN22
CN2L
CNDK
CND
CN32
CN31
CN51
1
2
3
4
5
31
31
31
1
2
DC13.1V
LED1
LED2
LED3
2
1
2
1
2
1
2
1
3
3
6
5
4
9
8
7
3
1
2
CN3C
CN20
CN21
CN41
CN29
1
2
3
4
1
2
1
2
2
1
1
2
TB5
Hi
52F
Lo
52F
X1
X1
X1
49F
51F
X6
X5
X4
12345
SW1
OFF
ON
SWE
OFF
ON
SWITCH (MODEL SELECTION)
SWITCH (CAPACITY CODE)
CONNECTOR (EMERGENCY OPERATION)
SNB
BOARD 1
ZNR5~7
VARISTOR
DSA,DSR
ARRESTER
INDOOR UNIT
NAME
SYMBOL
COND./EVA. TEMP.
LIQUID PIPE TEMP.
ROOM TEMP.
52FHi
MAGNETIC CONTACTOR (INDOOR FAN MOTOR<HIGH SPEED>)
SURGE KILLER
CR1,2
SW1
TH5
LED (TRANSMISSION<INDOOR·OUTDOOR>)
LED3
LED (POWER SUPPLY<REMOTE CONTROLLER>)
LED2
LED (POWER SUPPLY)
LED1
SWE
SW2
X4-6
AUXILIARY RELAY
VARISTOR
ZNR
FUSE (T6.3AL250V)
FUSE
THERMISTOR
TERMINAL BLOCK
INTERNAL THERMOSTAT (INDOOR FAN MOTOR)
OVER CURRENT RELAY (INDOOR FAN MOTOR)
FAN MOTOR (INDOOR)
TH2
TH1
TB2,4,5
49F
51F
MF1
52FLo
MAGNETIC CONTACTOR (INDOOR FAN MOTOR<LOW SPEED>)
AUXILIARY RELAY
X1
FERRITE CORE
FB
BOARD
CONTROLLER
INDOOR
CN2L
CN31
CN90
CN51
CN41
CN32
CONNECTOR (DRAIN SENSOR)
CONNECTOR (REMOTE SWITCH)
CONNECTOR (HA TERMINAL-A)
CONNECTOR (CENTRALLY CONTROL)
CONNECTOR (WIRELESS REMOTE CONTROLLER)
CONNECTOR (LOSSNAY)
4. Indoor and outdoor connecting wires have polarities, make sure
to match wiring and terminal.
5. Emergency operation
If a trouble occurs with either the remote controller or the indoor microcom-
puter and no other trouble exists, emergency operation for cooling or heating
can be performed by changing the setting of connector (SWE) "ON" on the
indoor controller board.
SWE :ON / Indoor fan is running at high speed.
TERMINAL BLOCK
TB6
SYMBOL
REMOTE CONTROLLER
NAME
SNB BOARD 1
REMOTE
CONTROLLER
BOARD
POWER BOARD
INDOOR
INDOOR
CONTROLLER
BOARD
Note:1. The dotted lines show field wiring.
2. Color of earth wire is yellow and green twisting.
3. Specification subject to change without notice.
51F
Caution,
1. To protect fan motor from abnormal current, overcurrent relays are installed.
Therefore, do not change factory set value of overcurrent relays.
6. mark is connector. mark is terminal.
CR1
CR2
ZNR5~7
TO OUTDOOR UNIT
CONNECTING WIRES
(POLAR)
OCS05E-2.qxp 08.3.31 10:21 AM Page 60
Содержание PUHZ-RP100VHA3
Страница 52: ...52 WIRED REMOTE CONTROLLER Unit mm 130 120 19 43 5 ...
Страница 53: ...53 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Страница 98: ...98 9 3 PLA RP AA PLA RP AA2 9 3 1 Fresh air intake amount ...
Страница 99: ...99 9 3 2 BRANCH DUCT Installation at site ...
Страница 108: ...108 PEAD RP60GA PEAD RP71GA ...
Страница 109: ...109 PEAD RP100GA ...
Страница 116: ...116 ...