2.PQHY-P-Y(S)HM-A
(1)
Specification
(1)-1 Heat source units specification for standard combination
(Standard CITY MULTI indoor units, PWFY-P100/200VM-E-AU)
*1
*2
Optional parts
Refrigerant
A
Current input
kW
A
kW
6
0
.
6
P
O
C
kW / kW
6.9-6.6-6.3
kW
kcal / h
*2 BTU / h
Power input
kW / kW
W.B.
5.71
-5.0~45.0°C(23~113°F)
Sound pressure level (measured in anechoic room)
dB <A>
25.0
15.0~24.0°C(59~75°F)
=kW x 860
=kW x 3,412
=m
3
/min x 35.31
=kg / 0.4536
kcal
BTU/h
cfm
lb
cooling
Circulating water
Heating capacity
Cooling capacity
47
15.0~27.0°C(59~81°F)
50~130 % of heat source unit capacity
P15~P250 / 1~17
-5.0~45.0°C(23~113°F)
85,300
4.12
1.0
KB94T222
5.0
195(430)
External dimension HxWxD
Motor output
kW
Lubricant
Case heater
kW
9.52(3/8) Brazed
19.05(3/4) Brazed
Inverter scroll hermetic compressor
4.5 ~ 7.2
4.6
Indoor LEV and BC controller
0.035(240 V)
High pressure sensor, High pressure switch at 4.15MPa (601 psi)
Protection
n
o
i
t
c
e
t
o
r
p
t
n
e
r
r
u
c
-
r
e
v
O
,
n
o
i
t
c
e
t
o
r
p
t
a
e
h
-
r
e
v
O
)
.
P
M
O
C
(
t
i
u
c
r
i
c
r
e
t
r
e
v
n
I
s
e
c
i
v
e
d
Unit converter
KE94C317
Refrigerant conn. pipe
Header: CMY-Y104/108/1010-G
*The specification data is
subject to rounding variation.
Wiring
Notes:
Standard attachment
Document
Operating volume range
m
3
/ h
Inverter
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
17
Joint: CMY-Y102S-G2
Remarks
●Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be refer
●Turn DipSW 3-9 ON before power ON.
red to the Installation Manual.
●Due to continuing improvement, above specifications may be subject to change without notice.
●The ambient temperature of the heat source unit needs to be kept below 40 °C D.B.
●The ambient relative humidity of the heat source unit needs to be kept below 80%.
●The heat source unit should not be installed at outdoor.
●Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit.
●Be sure to provide interlocking for the unit operation and water circuit.
●Add brine to circulating water when a unit is operating at water temperature below 10°C.
Drawing
External
Accessory
Water flow rate m
3
/ h
L/min
Pressure drop
kPa
mm
Compressor
in.
MPa
kg(lbs)
High pressure protection
Net weight
HIC circuit (HIC: Heat Inter-Changer)
Water volume in plate
Water pressure Max.
Compressor
water
Circulating
cfm
96
3.4
MEL32
1,160(1,100 without legs) x 880 x 550
45-11/16(43-5/16 without legs) x 34-11/16 x 21-11/16
Installation Manual
Power source
kW
h
/
l
a
c
k
)
l
a
n
i
m
o
N
(
*1
6.6-6.2-6.0
PQHY-P200YHM-A(For Ground source)
3-phase 4-wire 380-400-415V 50/60Hz
19,300
22.4
3.92
76,400
*1 BTU / h
Indoor unit
Temp. range of
Starting method
Type x Quantity
Manufacture
Power input
)
.
n
i
(
m
m
t
n
a
r
e
g
i
r
f
e
R
mm(in.)
Liquid pipe
Gas pipe
Current input
(Nominal)
D.B.
*2
COP
°C
Indoor
Temp. range of
Indoor
Model
External finish
Total capacity
piping diameter
Circulating water
°C
connectable
Model / Quantity
heating
21,500
5.76
Type x original charge
Control
l
Acrylic painted steel plate
Over-heat protection
R410A x 5.0kg (12lbs)
Heat exchanger
plate type
-
1.<Standard CITY MULTI indoor unit>
Nominal cooling conditions(subject to JIS B8615-1)
Indoor:27°CDB/19°CWB(81°FDB/66°FWB)
Water temperature:30°C(86°F)
Pipe length:7.5m(24-9/16ft.), Level difference:0m(0ft.)
Brine concentration 0%
2.<PWFY-P100/200VM-E-AU>
Nominal cooling conditions
Circulating water Temp. : 30°C (86°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 23°C
Water flow rate : 1.93m
3
/h (P100) / 3.86m
3
/h (P200)
Brine concentration 0%
Nominal heating conditions(subject to JIS B8615-1)
Indoor:20°CDB(68°FDB)
Water temperature:20°C(68°F)
Pipe length:7.5m(24-9/16ft.), Level difference:0m(0ft.)
Brine concentration 0%
Nominal heating conditions
Circulating water Temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 30°C
Water flow rate : 2.15m
3
/h (P100) / 4.30m
3
/h (P200)
Brine concentration 0%