12
Having trouble?
Here is the solution. (Unit is operating normally.)
Noise is louder than specifications.
The indoor operation sound level is affected by the acoustics of the
particular room as shown in the following table and will be higher than
the noise specification, which was measured in an echo-free room.
High sound-
absorbing rooms
Normal rooms
Low sound-
absorbing rooms
Location
examples
Broadcasting
studio, music
room, etc.
Reception room,
hotel lobby, etc.
Office, hotel
room
Noise levels
3 to 7 dB
6 to 10 dB
9 to 13 dB
Nothing appears in the wireless remote controller display, the display
is faint, or signals are not received by the indoor unit unless the remote
controller is close.
The batteries are low.
Replace the batteries and press the Reset button.
If nothing appears even after the batteries are replaced, make sure
that the batteries are installed in the correct directions (+, –).
The operation lamp near the receiver for the wireless remote controller
on the indoor unit is flashing.
The self diagnosis function has operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be
sure to provide the dealer with the model name.
8. Specifications
Model
PKA-M60KA(L)
PKA-M71KA(L)
PKA-M100KA(L)
Power source (voltage <V>/Frequency <Hz>)
~N/230/50
Rated Input (Indoor only)
<kW>
0.06
0.06
0.08
Rated Current (Indoor only)
<A>
0.43
0.43
0.57
Heater <kW>
–
–
–
Dimension (Height)
<mm>
365
Dimension (Width)
<mm>
1170
Dimension (Depth)
<mm>
295
Fan airflow volume (Low-Middle-High)
<m
3
/min>
18-20-22
20-23-26
Noise level (Low-Middle-High)
<dB>
39-42-45
41-45-49
Net weight
<kg>
21
7. Troubleshooting
RG79Y870H01_en.indd 12
12/21/2016 4:12:54 PM