4. The Smart Way to Use

Even minimal steps to care for your unit can help make its use far more 
effective in terms of air-conditioning effect, electricity charges, etc.

Clean the filter thoroughly

• If the screen of the air filter becomes clogged, the airflow and air-conditioning 

effect can be significantly reduced.
Further, if the condition is left unattended, failure can result. It is particularly 
important to clean the filter at the beginning of the cooling and heating seasons. 
(When profuse dust and dirt have accumulated, clean the filter thoroughly.)

Prevent intrusion of heat during air-cooling

• To prevent the intrusion of heat during cooling operation, provide a curtain or a 

blind on the window to block out direct sunlight. Also, do not open the entrance 
or exit except in cases of dire necessity. 

Carry out ventilation sometimes

• Since the air periodically gets dirty in a room that is kept closed for a long time, 

ventilation is sometimes necessary. When gas appliances are used together 
with the unit, special precautions must be taken. If the “LOSSNAY” ventilation 
unit developed by our company is used, you can perform ventilation with less 
waste. For details on this unit, consult with your dealer.

5. Caring for the Unit

Always have filter maintenance performed by an authorized service person.
Before care-taking, turn the power supply OFF.

Caution:

• Before you start cleaning, stop operation and turn OFF the power supply. 

Remember that the fan is rotating inside at high speed, posing a serious 
risk of injury.

• Indoor units are equipped with filters to remove the dust of sucked-in air. 

The standard filter should normally be cleaned once a week.

• The life of the filter depends on where the unit is installed and how it is 

operated.

How to clean

• Clear dust away lightly or clean it up with a vacuum cleaner. In the case of 

severe staining, wash the filter in lukewarm water mixed with dissolved neutral 
detergent or water, and then rinse off the detergent completely. After washing, 
dry it and fix it back into place.

Caution:

• Do not dry the filter by exposing it to direct sunlight or warming it using 

fire, etc. Doing so can result in the deformation of the filter.

• Washing it in hot water (more than 50 °C) can also result in deformation.

Caution:

Never pour water or flammable sprays onto the unit. Cleaning using these 
methods can result in the failure of the unit, electric shock, or fire.

6. Troubleshooting

Before you call out a repair man, check the following table to see whether there is 
a simple solution to your problem.

z

Unit does not cool very well.

• Clean the filter. (Dust and debris that collects in the filter will decrease 

airflow.)

• Check the temperature setting and adjust it if necessary.
• Increase the space surrounding the unit.

Is the air intake or air outlet blocked?

• Is a window or door open?

z

There is a “swishing” noise that occurs from the unit when water flows.

• This sound is made when refrigerant inside of the unit is flowing or refilling.

z

A ticking noise is heard from inside of the unit.

• This sound is made when internal parts of the unit expand or contract when 

the temperature changes.

z

A white mist is expelled from the indoor unit.

• This may occur just after the unit is turned on when a high level of humidity is 

present in the room.

z

Water or moisture is expelled from the outdoor unit.

• This occurs to expel water or moisture that may have collected in the pipes 

or around piping fixtures.

• This occurs to dispel water from the heat exchanger.

z

The indicators of the remote controller do not light up when operated.

• Turn on the power. “

€

” will be displayed.

z

 indicator is displayed in the remote controller.

• The start and stop or operation mode or set temperature functions of the 

remote controller are not available when the 

 indicator is lit.

z

The start and stop functions are not available just after restarting the 
unit.

• Wait about three minutes (operation has stopped to prevent damage to the 

air conditioner).

z

The unit started even though the start/stop button was not pushed.

• Is the timer on?

Press the start/stop button to stop the unit.

• Was a distant command sent from the remote controller?

Find out if the remote controller was used.

• Is the 

 indicator lit?

Find out if the remote controller was used.

• Is the automatic (cooling/heating) mode selected?

Press the start/stop button to stop the unit.

• If the power start/stop function is set, operation starts automatically when the 

power of the indoor unit is turned on. 

• If the power cut auto recovery function is set, operation starts automatically 

when the power is turned on after a power cut occurred or the power was 
turned off during operation.  

* If the power start/stop function or power cut auto recovery function is not 

needed, consult the dealer. 

z

The unit stopped even though the start/stop button was not pushed.

• Is the timer on?

Press the start/stop button to restart the unit.

• Was a distant command sent from the remote controller?

Find out if the remote controller was used.

• Is the 

 indicator lit?

Find out if the remote controller was used.

z

“PLEASE WAIT” is displayed in the remote controller.

• An automatic startup test is being performed (will last for about five minutes).

z

An error code is displayed in the remote controller.

• A self-diagnostic function is being performed to preserve the air conditioner.

* Do not attempt to make repairs yourself. Turn the main switch off and 

contact the dealer from whom you bought the air conditioner. Provide him 
or her with the name of the unit and the information displayed in the 
remote controller.

z

The unit does not stop even though the stop button was pressed. 

• If the stop button is pressed during the heating operation, the indoor unit fan 

sometimes rotates for approximately 1 minute in order to dissipate residual 
heat.

• Depending on the indoor unit settings, the indoor unit fan sometimes rotates 

for approximately 3 minute after operation stops in order to dissipate residual 
heat.

z

The “Central Control” indication is displayed on the remote controller 
display area.

• This indication is displayed when operation is restricted by, for example, the 

centralized controller. 

• This indication is displayed when the operation setting is set to remote 

(external) input.

z

The operation indicator on the remote controller lights, but the outdoor 
unit does not operate. 

• If a demand is input to the indoor unit or outdoor unit, the outdoor unit does 

not operate.

z

Air is not blown soon after starting the heating operation. 

• The unit requires time to prepare in order to blow air that is sufficiently warm. 

Wait a while.

z

Operation stops while the heating operation dose not reach the set 
temperature. 

• Frost forms in the outdoor unit when the outside air temperature is low and 

the humidity is high. The frost is being melted. Wait approximately 10 
minutes. 

If malfunctions persist after you have checked the above, turn the power supply 
OFF and contact your dealer with information about the product name, the nature 
of the malfunction, etc. If the display of “[check]” and (4 digit) check code flashes, 
tell the dealer contents of the display (check code). Never attempt to repair by 
yourself.

00gb_WT05475X02_7.book  Page 17  Tuesday, June 16, 2009  12:33 PM

Содержание PFAV-P250VM-E

Страница 1: ...la unidad de aire acondicionado para garantizar un uso seguro y correcto ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa MANUAL DE OPERAÇÃO Para segurança e utilização correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado IŞLETME ELKİTABI Emniyetli ...

Страница 2: ...dicator Fig 2 1 PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF Down Up Opening the door Set Temperature buttons Note z If you press a button for a feature that is not installed at the indoor unit the remote controller will display the Not Available message If you are using the remote controller to drive multiple indoor units this message will appear ...

Страница 3: ...Side panel D Operation section MA remote controller C Front top panel K Air outlet louver C Front top panel H Earth screw in the electrical components box A Front bottom panel D Operation section MA remote controller Q Inlet rear R Drain outlet of heat exchanger the bottom side of heat exchanger P Intake duct flange with a filter inside O Outlet on top I Blow duct flange S Drain outlet rear of bas...

Страница 4: ...nce Do not stand on the unit 1 Outdoor unit Warning The outdoor unit must be installed on a stable level surface in a place where there is no accumulation of snow leaves or rubbish Do not stand on or place any items on the unit You may fall down or the item may fall causing injury Caution The outdoor unit should be installed in a location where air and noise emitted by the unit will not disturb th...

Страница 5: ...dealer Leaving it as it is can result in fire or failure If the refrigeration gas blows out or leaks stop the operation of the unit thoroughly ventilate the room and contact your dealer Leaving the unit as it is can result in accidents due to oxygen deficiency When the unit is not to be used for a long time If the unit is not to be used for a long time due to a seasonal change etc run it for 4 5 h...

Страница 6: ...the ON OFF button 1 The ON lamp 1 and the display area come on Note z When the unit is restarted initial settings are as follows To Stop Operation Press the ON OFF button 1 again The ON lamp 1 and the display area go dark Selecting the Mode With the unit running press the Mode button 2 as many times as necessary Each press switches operation to the next mode in the sequence shown below The current...

Страница 7: ...entilation button 8 while the indoor unit is off The On lamp at 1 and the Vent indication at 8 come on z To change the ventilator force Press the Ventilation button 8 as necessary Each press toggles the setting as shown below Note z With some model configurations the fan on the indoor unit may come on even when you set the ventilator to run independently 3 Using the Timer This section explains how...

Страница 8: ... stop times The air conditioner starts and stops at the respective elapsed times The simple timer start and stop can be set only once within a 72 hour period The time setting is made in hour increments Note 1 Weekly Timer Simple Timer Auto Off Timer cannot be used at the same time 2 The simple timer will not operate when any of the following conditions is in effect The timer is off the system is i...

Страница 9: ...oller see 3 4 4 3 3 timer function setting 2 Hold down the Timer Menu button b for 3 seconds so that the Set Up screen appears Note that each press of the button toggles the display between Set Up and TIMER MONITOR 3 Press the appropriate Set Time button a as necessary to set the OFF time at 3 4 Press the Filter button 4 to lock in the setting Note Your entry will be cancelled if you press the Mod...

Страница 10: ...d indication disappears from the screen at 1 5 Other Indications Centrally Controlled z Displayed when operation is controlled by central controller etc Restricted operations are shown below ON OFF including timer operation Operation mode Set temperature Note May also be individually restricted Flashing Mode Indicator When flashes continuously Displayed when another indoor unit connected to the ou...

Страница 11: ...u should note down the error code and then call your dealer or servicer for advice If you have entered contact number to be called in the event of a problem push the Check button to display it on the screen You can set this up under Function Selection of remote controller For information refer to section 3 4 ON OFF ERROR CODE If you have entered contact number to be called in the event of a proble...

Страница 12: ...BACK DAY MONITOR SET CLOCK ON OFF F G C D B I A H E Normal display Display when the air condition is not running Hold down the E button and press the D button for two seconds The display cannot be changed during the unit function selection the test run and the self diagnosis Hold down the E button and press the D button for two seconds The remote controller records the setting that is made in this...

Страница 13: ...imer can be used 4TIMER MODE OFF The timer mode cannot be used When the use of clock setting is OFF the WEEKLY TIMER cannot be used 4 Contact number setting for error situation To switch the setting press the ON OFF button D 1CALL OFF The set convtact numbers are not displayed in case of error 2CALL The set contact numbers are displayed in case of error CALL_ The contact number can be set when the...

Страница 14: ...ect polarity Using a DC500 V Mega check that the resistance between the power supply terminal block and earth is 1 0 MΩ or more Do not operate if this resistance is less than 1 0 MΩ Never measure the insulation resistance of the terminal blocks for the MA remote controller and transmission cables 2 Test Run Using Remote Controller 1 Press the TEST button twice successively within three seconds Tes...

Страница 15: ...ly 6 minutes Error codes for which emergency operation is possible common to OC and OS Capacity is reduced during emergency operation Capacity varies depending on the number of outdoor units that have failed 2 Ending Emergency Operation End condition When communication recovers emergency operation ends and the mode becomes normal mode 3 9 Self Check Retrieve the error history of each unit using th...

Страница 16: ...her remote controllers Data error count is the difference between the number of bits of remote controller send data and the number of bits actually sent to the transmission line In this case the send data was disturbed by the noise etc Check the transmission line Remote controller send data Send data on transmission line When data error count is 02 4 Remote controller check reset When the CHECK bu...

Страница 17: ...e indicators of the remote controller do not light up when operated Turn on the power will be displayed z indicator is displayed in the remote controller The start and stop or operation mode or set temperature functions of the remote controller are not available when the indicator is lit z The start and stop functions are not available just after restarting the unit Wait about three minutes operat...

Страница 18: ...rician according to the local regulation and the installation instruction manual with the absolute use of exclusive circuits The use of other products with the power source can result in burnt out breakers and fuses Never connect the grounding wire to a gas pipe water pipe arrester or telephone grounding wire For details consult with your dealer In some types of installation sites the installation...

Страница 19: ...DB 6 C WB 2 The operating noise is the data that was obtained in an anechoic room PFAV P VM E F series Cooling Heating Notes 1 Cooling Heating capacity indicates the rated value at operation under the following condition Cooling Indoor Outdoor 33 C DB 28 C WB Heating Indoor Outdoor 7 C DB 3 C WB 2 The operating noise is the data that was obtained in an anechoic room 3 If the indoor unit intake air...

Страница 20: ...tions of high temperature or humidity or in locations in which variations in temperature and humidity are considerable 2Use in locations in which power supply variations e g voltage frequency waveform distortion are considerable Note that the unit cannot be used outside the allowable range of conditions 3Use in locations subject to considerable vibration and shock 4Use in an atmosphere containing ...

Страница 21: ...ial commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Please be sure to put the contact address telephone number on this manual before handing it to the customer 00gb_WT05475X02_7 book Page 24 Tuesday June 16 2009 12 33 PM ...

Отзывы: