13

GB

[Detailed setting]

[4]–1. CHANGE LANGUAGE setting

The language that appears on the dot display can be selected.

• Press the [

MENU] button 

G

 to change the language.

1

 Japanese (JP), 

2

 English (GB), 

3

 German (D), 

4

 Spanish (E), 

5

 Russian (RU), 

6

 Italian (I), 

7

 Chinese (CH), 

8

 French (F)

[4]–2. Function limit

(1) Operation function limit setting (operation lock)

• To switch the setting, press the [

ON/OFF] button 

D

.

1

no1 : Operation lock setting is made on all buttons other than the 

[

ON/OFF] button.

2

no2 : Operation lock setting is made on all buttons.

3

OFF (Initial setting value) : Operation lock setting is not made.

* To make the operation lock setting valid on the normal screen, it is 

necessary to press buttons (Press and hold down the [FILTER] and 
[

ON/OFF] buttons at the same time for two seconds.) on the normal 

screen after the above setting is made.

(2) Use of automatic mode setting
This unit does not include automatic mode functions. 

(3) Temperature range limit setting

After this setting is made, the temperature can be changed within the set 
range.
• To switch the setting, press the [

ON/OFF] button 

D

.

1

LIMIT TEMP COOL MODE :
The temperature range can be changed on cooling mode.

2

LIMIT TEMP HEAT MODE :
The temperature range can be changed on heating mode.

3

OFF (initial setting): The temperature range limit is not active.

* When the setting, other than OFF, is made, the temperature range limit 

setting on cooling, heating mode is made at the same time. However, the 
range cannot be limited when the set temperature range has not 
changed.

• To increase or decrease the temperature, press the [

TEMP. (

) or 

(

)] button 

F

.

• To switch the upper limit setting and the lower limit setting, press the 

[

] button 

H

. The selected setting will flash and the temperature can 

be set.

• Settable range

Cooling mode: Lower limit: 14°C (19°C ) ~ 30°C

Upper limit: 30°C ~ 14°C (19°C )

Heating mode: Lower limit: 17°C ~ 28°C

Upper limit: 28°C ~ 17°C

* The settable range varies depending on the unit to connect.

(4) Use of automatic filter elevation panel up/down operation mode setting

This unit does not include an automatic filter up/down function. 

(5) Use of fixed airflow direction mode setting

This unit does not include an airflow direction adjustment function. 

[4]–3. Mode selection setting

(1) Remote controller main/sub setting

• To switch the setting, press the [

ON/OFF] button 

D

.

1

Main : The controller will be the main controller.

2

Sub : The controller will be the sub controller.

(2) Use of clock setting

• To switch the setting, press the [

ON/OFF] button 

D

.

1

ON : The clock function can be used.

2

OFF: The clock function cannot be used.

(3) Timer function setting

• To switch the setting, press the [

ON/OFF] button 

D

 (Choose one of 

the followings.).

1

WEEKLY TIMER (initial setting value): The weekly timer can be used.

2

AUTO OFF TIMER : The auto off timer can be used.

3

SIMPLE TIMER

: The simple timer can be used.

4

TIMER MODE OFF: The timer mode cannot be used.

* When the use of clock setting is OFF, the “WEEKLY TIMER” cannot be 

used.

(4) Contact number setting for error situation

• To switch the setting, press the [

ON/OFF] button 

D

.

1

CALL OFF

: The set convtact numbers are not displayed in 

case of error.

2

CALL **** *** **** : The set contact numbers are displayed in case of 

error.

CALL_

: The contact number can be set when the display is 

as shown on the left.

• Setting the contact numbers

To set the contact numbers, follow the following procedures.
Move the flashing cursor to set numbers. Press the [

TEMP. (

) and 

(

)]  button 

F

 to move the cursor to the right (left). Press the 

[

CLOCK (

) and (

)] button 

C

 to set the numbers.

[4]–4. Display change setting

(1) Temperature display °C/°F setting

• To switch the setting, press the [

ON/OFF] button 

D

.

1

°C : The temperature unit °C is used.

2

°F : The temperature unit °F is used.

(2) Suction air temperature display setting

• To switch the setting, press the [

ON/OFF] button 

D

.

1

ON : The suction air temperature is displayed.

2

OFF: The suction air temperature is not displayed.

(3) Automatic cooling/heating display setting

This unit does not include automatic mode functions. 

3.5. Ventilation Setting

* When the upper controller is connected, make the setting using the upper 

controller.

Perform this operation when you want to register the LOSSNAY, confirm the 
registered units, or delete the registered units controlled by the remote controller.
The following uses indoor unit address 05 and LOSSNAY address 30 as an 
example to describe the setting procedure.

[Setting Procedure]

1

Stop the air conditioner using the remote controller [

ON/OFF] button.

If the OFF display shown below does not appear at this time, step 

2

 cannot 

be performed.

2

Press and hold down the [FILTER] and [

] buttons at the same time for 

two seconds. The display shown below appears. The remote controller 
confirms the registered LOSSNAY addresses of the currently connected 
indoor units.

3

Registration confirmation result
- The indoor unit address and registered LOSSNAY address are displayed 

alternately.

- When LOSSNAY are not registered

4

If registration is unnecessary, end registration by pressing and holding down 
the [FILTER] and [

] buttons at the same time for two seconds.

If a new LOSSNAY must be registered, go to step 

1. Registration 

procedure

. If you want to confirm another LOSSNAY, go to step 

2. Confirmation procedure

. To delete a registered LOSSNAY, go to step 

3. Deletion procedure

.

< 1. Registration procedure >

5

Set the address of the LOSSNAY and the indoor unit connected by the 
remote controller you want to register using the [

TEMP. (

) and (

)] 

buttons. (01 to 50)

Make this setting only when interlocked operation with LOSSNAY is 
necessary.

NOTE: When using LOSSNAY units in conjunction, interlock the 

addresses of all indoor units within the group and address of 
LOSSNAY units.

<Indoor unit address and indoor unit 
display>

<LOSSNAY address display and 
LOSSNAY display>

00gb_WT05475X02_7.book  Page 13  Tuesday, June 16, 2009  12:33 PM

Содержание PFAV-P250VM-E

Страница 1: ...la unidad de aire acondicionado para garantizar un uso seguro y correcto ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa MANUAL DE OPERAÇÃO Para segurança e utilização correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado IŞLETME ELKİTABI Emniyetli ...

Страница 2: ...dicator Fig 2 1 PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF Down Up Opening the door Set Temperature buttons Note z If you press a button for a feature that is not installed at the indoor unit the remote controller will display the Not Available message If you are using the remote controller to drive multiple indoor units this message will appear ...

Страница 3: ...Side panel D Operation section MA remote controller C Front top panel K Air outlet louver C Front top panel H Earth screw in the electrical components box A Front bottom panel D Operation section MA remote controller Q Inlet rear R Drain outlet of heat exchanger the bottom side of heat exchanger P Intake duct flange with a filter inside O Outlet on top I Blow duct flange S Drain outlet rear of bas...

Страница 4: ...nce Do not stand on the unit 1 Outdoor unit Warning The outdoor unit must be installed on a stable level surface in a place where there is no accumulation of snow leaves or rubbish Do not stand on or place any items on the unit You may fall down or the item may fall causing injury Caution The outdoor unit should be installed in a location where air and noise emitted by the unit will not disturb th...

Страница 5: ...dealer Leaving it as it is can result in fire or failure If the refrigeration gas blows out or leaks stop the operation of the unit thoroughly ventilate the room and contact your dealer Leaving the unit as it is can result in accidents due to oxygen deficiency When the unit is not to be used for a long time If the unit is not to be used for a long time due to a seasonal change etc run it for 4 5 h...

Страница 6: ...the ON OFF button 1 The ON lamp 1 and the display area come on Note z When the unit is restarted initial settings are as follows To Stop Operation Press the ON OFF button 1 again The ON lamp 1 and the display area go dark Selecting the Mode With the unit running press the Mode button 2 as many times as necessary Each press switches operation to the next mode in the sequence shown below The current...

Страница 7: ...entilation button 8 while the indoor unit is off The On lamp at 1 and the Vent indication at 8 come on z To change the ventilator force Press the Ventilation button 8 as necessary Each press toggles the setting as shown below Note z With some model configurations the fan on the indoor unit may come on even when you set the ventilator to run independently 3 Using the Timer This section explains how...

Страница 8: ... stop times The air conditioner starts and stops at the respective elapsed times The simple timer start and stop can be set only once within a 72 hour period The time setting is made in hour increments Note 1 Weekly Timer Simple Timer Auto Off Timer cannot be used at the same time 2 The simple timer will not operate when any of the following conditions is in effect The timer is off the system is i...

Страница 9: ...oller see 3 4 4 3 3 timer function setting 2 Hold down the Timer Menu button b for 3 seconds so that the Set Up screen appears Note that each press of the button toggles the display between Set Up and TIMER MONITOR 3 Press the appropriate Set Time button a as necessary to set the OFF time at 3 4 Press the Filter button 4 to lock in the setting Note Your entry will be cancelled if you press the Mod...

Страница 10: ...d indication disappears from the screen at 1 5 Other Indications Centrally Controlled z Displayed when operation is controlled by central controller etc Restricted operations are shown below ON OFF including timer operation Operation mode Set temperature Note May also be individually restricted Flashing Mode Indicator When flashes continuously Displayed when another indoor unit connected to the ou...

Страница 11: ...u should note down the error code and then call your dealer or servicer for advice If you have entered contact number to be called in the event of a problem push the Check button to display it on the screen You can set this up under Function Selection of remote controller For information refer to section 3 4 ON OFF ERROR CODE If you have entered contact number to be called in the event of a proble...

Страница 12: ...BACK DAY MONITOR SET CLOCK ON OFF F G C D B I A H E Normal display Display when the air condition is not running Hold down the E button and press the D button for two seconds The display cannot be changed during the unit function selection the test run and the self diagnosis Hold down the E button and press the D button for two seconds The remote controller records the setting that is made in this...

Страница 13: ...imer can be used 4TIMER MODE OFF The timer mode cannot be used When the use of clock setting is OFF the WEEKLY TIMER cannot be used 4 Contact number setting for error situation To switch the setting press the ON OFF button D 1CALL OFF The set convtact numbers are not displayed in case of error 2CALL The set contact numbers are displayed in case of error CALL_ The contact number can be set when the...

Страница 14: ...ect polarity Using a DC500 V Mega check that the resistance between the power supply terminal block and earth is 1 0 MΩ or more Do not operate if this resistance is less than 1 0 MΩ Never measure the insulation resistance of the terminal blocks for the MA remote controller and transmission cables 2 Test Run Using Remote Controller 1 Press the TEST button twice successively within three seconds Tes...

Страница 15: ...ly 6 minutes Error codes for which emergency operation is possible common to OC and OS Capacity is reduced during emergency operation Capacity varies depending on the number of outdoor units that have failed 2 Ending Emergency Operation End condition When communication recovers emergency operation ends and the mode becomes normal mode 3 9 Self Check Retrieve the error history of each unit using th...

Страница 16: ...her remote controllers Data error count is the difference between the number of bits of remote controller send data and the number of bits actually sent to the transmission line In this case the send data was disturbed by the noise etc Check the transmission line Remote controller send data Send data on transmission line When data error count is 02 4 Remote controller check reset When the CHECK bu...

Страница 17: ...e indicators of the remote controller do not light up when operated Turn on the power will be displayed z indicator is displayed in the remote controller The start and stop or operation mode or set temperature functions of the remote controller are not available when the indicator is lit z The start and stop functions are not available just after restarting the unit Wait about three minutes operat...

Страница 18: ...rician according to the local regulation and the installation instruction manual with the absolute use of exclusive circuits The use of other products with the power source can result in burnt out breakers and fuses Never connect the grounding wire to a gas pipe water pipe arrester or telephone grounding wire For details consult with your dealer In some types of installation sites the installation...

Страница 19: ...DB 6 C WB 2 The operating noise is the data that was obtained in an anechoic room PFAV P VM E F series Cooling Heating Notes 1 Cooling Heating capacity indicates the rated value at operation under the following condition Cooling Indoor Outdoor 33 C DB 28 C WB Heating Indoor Outdoor 7 C DB 3 C WB 2 The operating noise is the data that was obtained in an anechoic room 3 If the indoor unit intake air...

Страница 20: ...tions of high temperature or humidity or in locations in which variations in temperature and humidity are considerable 2Use in locations in which power supply variations e g voltage frequency waveform distortion are considerable Note that the unit cannot be used outside the allowable range of conditions 3Use in locations subject to considerable vibration and shock 4Use in an atmosphere containing ...

Страница 21: ...ial commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Please be sure to put the contact address telephone number on this manual before handing it to the customer 00gb_WT05475X02_7 book Page 24 Tuesday June 16 2009 12 33 PM ...

Отзывы: