Confirm that the box includes the following parts, in addition to this installation manual:
(1) Remote controller (Body, lower case) ........................................................
(2) Cable for external input (5 wire) .................................................................
(3) Cable for external output (4 wire)...............................................................
(4) Cross recessed pan head screw (M4
×
30) ...............................................
(5) Wood screw (4.1
×
16, used for directly hooking to the wall).....................
(6) Room name label or room name record sheet...........................................
(7) Operation Manual.......................................................................................
2 Confirming the Supplied Parts
Remote
controller
lower case
Remote
controller
body
NOTE:
The remote control cord is not supplied with the product.
Prepare electrical wiring that conforms to the specifications given below.
Electrical wiring specification (CVVS)
Use 1.25mm
2
cable for any extension that exceeds 10m.
¥ 10m or shorter
: 0.75mm
2
two-wire cable
¥ Longer than 10m : 1.25mm
2
two-wire cable
Remote controller wiring entry points can support electrical
wiring of maximum 1.25mm
2
.
However 0.75mm
2
electrical wiring is recommended for use.
3 System Configurations
(Refer to the "System Design and Work Manual" for the outdoor unit for details.)
Central management
transmission line
Indoor and
outdoor transmission line
Interlocked operation
with ventilation unit
Indoor unit
LOSSNAY
(independent/
interlocked)
M-NET remote controller
Outdoor unit
(1) When connecting to a central management transmission line
A power supply unit (PAC-SC34KUA) is required.
* The power consumption of the system controller, schedule timer and group remote controller is half of the ON/OFF remote
controller. Thus, interpret the power consumption per unit as half of the ON/OFF remote controller.
Power supply unit
PAC-SC34KUA
Number of connected system controllers
1 to 5 units
ON/OFF remote controller
1 to 10 units
System remote controller
schedule timer
group remote controller
Schedule timer
PAC-YT34STA
ON/OFF
remote controller
PAC-YT40ANRA
[051]
CN41
Leave as is
TB7
TB3
1
SW2-1[ON]
ON
OFF
2 3 4 5 6 7 8 9 10
Group 2
[003]
[002]
[001]
[005]
[004]
[006]
[007]
[009]
[101]
[102]
[103]
[105]
[106]
[107]
[201]
[202]
[203]
Group 1
Group 3
Group 4
Group 7
Group 6
Group 5
System
remote controller
PAC-SF44SRA
[008]
[108]
Power supply unit
Model: PAC-SC34KUA
[052]
CN41
TB7
TB3
1
SW2-1[ON]
* Outdoor unit
: SW position
ON
OFF
2 3 4 5 6 7 8 9 10
Leave as is
* Number of units that can be supplied with power supply unit (For above system)
One system remote controller
One schedule timer
One ON/OFF remote controller
1
×
1/2 + 1
×
1/2 + 1
×
1 = 2 (unit)
1
1
1
2
2
1
1