12
OCH729
DISASSEMBLY PROCEDURE
PHOTOS/ FIGURES
5. How to remove the flow water temp. & return water
temp. thermistor (THW6, THW7, THW8, THW9)
(1) Remove the front panel (Refer to Procedure 1).
(2) Disconnect the removing thermistor connector from the
controller board of the cylinder unit (hydrobox) (Photo
5-1).
Thermistor Connecting part of the controller board
THW6
TBI.5 7-8
THW7
TBI.5 5-6
THW8
TBI.5 3-4
THW9
TBI.5 1-2
(3) Release the lead wires from the following fixtures:
(Photo 4-1 and 5-1)
• Cable straps on the 2 zone kit
• Cable straps and cable clamps in the control box of
the cylinder unit (hydrobox)
• Cable straps on the cylinder unit (hydrobox)
(4) Remove the thermistor from the holder (Photo 5-2).
Photo 5-1
Photo 5-2
6. How to remove the air vent (manual)
(1) Remove the front panel (Refer to Procedure 1).
(2) Remove the air vent (manual) by turning the air vent
(manual). (Photo 6)
Photo 6
TBO.2 1-3
Cable
clamps
Thermistor connectors
Air vent (manual)
Thermistor
(THW8)
Thermistor
(THW6)
Thermistor
(THW9)
Thermistor
(THW7)
Cable strap
Содержание PAC-TZ02-E