background image

En-

n

  Do not install the unit by yourself (user).

  Incomplete installation could cause fire or electric shock, injury due to the unit 

falling, or leakage of water. Consult the dealer from whom you purchased the 

unit or a qualified installer.

n

  Perform the installation securely referring to the installation manual.

  Incomplete installation could cause fire or electric shock, injury due to the unit 

falling, or leakage of water. 

When installing the unit, use appropriate protective equipment and tools 

for safety.

  Failure to do so could cause injury.

n

  Install the unit securely in a place which can bear the weight of the unit.

  If the installation location cannot bear the weight of the unit, the unit could fall 

causing injury.

Perform electrical work according to the installation manual and be sure 

to use an exclusive circuit. Do not connect other electrical appliances to 

the circuit.

  If the capacity of the power circuit is insufficient or there is incomplete electri

-

cal work, it could result in a fire or an electric shock.

Do not damage the wires by applying excessive pressure with parts or 

screws.

  Damaged wires could cause fire.

Be sure to cut off the main power in case of setting up the indoor P.C. 

board or wiring works.

  Failure to do so could cause electric shock.

n

  Use the specified wires to connect the indoor and outdoor units secure-

ly and attach the wires firmly to the terminal block connecting sections 

so the stress of the wires is not applied to the sections.

  Incomplete connecting and securing could cause fire.

Do not install the unit in a place where inflammable gas may leak.

  If gas leaks and accumulates in the area around the unit, it could cause an 

explosion.

n

  Do not use intermediate connection of the power cord or the extension 

cord and do not connect many devices to one AC outlet.

  It could cause a fire or an electric shock due to defective contact, defective 

insulation, exceeding the permissible current, etc.

Be sure to use the parts provided or specified parts for the installation 

work.

  The use of defective parts could cause an injury or leakage of water due to a 

fire, an electric shock, the unit falling, etc.

When plugging the power supply plug into the outlet, make sure that there 

is no dust, clogging, or loose parts in both the outlet and the plug. Make 

sure that the power supply plug is pushed completely into the outlet. 

  If there is dust, clogging, or loose parts on the power supply plug or the outlet, 

it could cause electric shock or fire. If loose parts are found on the power sup

-

ply plug, replace it.

Attach the electrical cover to the indoor unit and the service panel to the 

outdoor unit securely.

  If the electrical cover of the indoor unit and/or the service panel of the out

-

door  unit  are  not  attached  securely,  it  could  result  in  a  fire  or  an  electric 

shock due to dust, water, etc.

When  installing,  relocating,  or  servicing the  unit,  make  sure  that  no 

substance other than the specified refrigerant (R410A) enters the re-

frigerant circuit.

  Any presence of foreign substance such as air can cause abnormal pres-

sure rise and may result in explosion or injury. The use of any refrigerant 

other than that specified for the system will cause mechanical failure, sys

-

tem malfunction, or unit breakdown. In the worst case, this could lead to a 

serious impediment to securing product safety.

Do  not  discharge  the  refrigerant  into  the  atmosphere.  If  refrigerant 

leaks during installation, ventilate the room.

  If refrigerant comes in contact with a fire, harmful gas could be generated. Re

-

frigerant leakage may cause suffocation. Ventilate the room.

Check that the refrigerant gas does not leak after installation has been 

completed.

  If refrigerant gas leaks indoors, and comes into contact with the flame of a 

fan heater, space heater, stove, etc., harmful substances will be generated.

Use appropriate tools and piping materials for installation. 

  The pressure of R40A is .6 times more than R22. Not using appropriate 

tools or materials and incomplete installation could cause the pipes to burst 

or injury. 

When pumping down the refrigerant, stop the compressor before dis-

connecting the refrigerant pipes.

  If  the  refrigerant  pipes  are  disconnected  while  the  compressor  is  running 

and the stop valve is open, air could be drawn in and the pressure in the re

-

frigeration cycle could become abnormally high. This could cause the pipes 

to burst or injury. 

When installing the unit, securely connect the refrigerant pipes before 

starting the compressor.

  If the compressor is started before the refrigerant pipes are connected and 

when the stop valve is open, air could be drawn in and the pressure in the 

refrigeration  cycle  could  become  abnormally  high.  This  could  cause  the 

pipes to burst or injury.

Fasten a flare nut with a torque wrench as specified in this manual.

  If fastened too tight, a flare nut may break after a long period and cause re

-

frigerant leakage.

The unit shall be installed in accordance with national wiring regula-

tions. 

n

  Ground the unit correctly.

  Do not connect the ground to a gas pipe, water pipe, lightning rod or tel-

ephone ground. Defective grounding could cause electric shock.

n

  Be sure to install a Ground Fault Interrupt (GFI) circuit breaker.

  Failure to install a Ground Fault Interrupt (GFI) circuit breaker may result in 

electric shock or fire.

1-2. SPECIFICATIONS

1.  BEFORE INSTALLATION

1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

•  Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.

•  Be sure to observe the warnings and cautions specified here as they include important items related to safety.

•  After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.

 

CAUTION

(Could lead to serious injury in particular environments when operated incorrectly.)

n

  Perform the drainage/piping work securely according to the installation 

manual.

  If there is defect in the drainage/piping work, water could drop from the unit, 

soaking and damaging household goods.

n

  Do not touch the air inlet or the aluminum fins of the outdoor unit.

  This could cause injury. 

n

  Do not install the outdoor unit where small animals may live.

  If small animals enter and touch the electric parts inside the unit, it could 

cause a malfunction, smoke emission, or fire. Also, advise user to keep the 

area around the unit clean. 

 

WARNING

(Could lead to death, serious injury, etc.)

Required Tools for Installation

Phillips screwdriver

Level

Scale

Utility knife or scissors

Torque wrench

Wrench (or spanner)

5/32 in. (4 mm) hexagonal 

wrench

Flare tool for R40A

Gauge manifold for R40A

Vacuum pump for R410A

Charge hose for R40A

Pipe cutter with reamer

 ENGLISH

CONTENTS

. BEFORE INSTALLATION ............................................................

2. OUTDOOR UNIT INSTALLATION ...............................................4

3. FLARING WORK AND PIPE CONNECTION

 ...............................5

4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN

 ......... 5

5. PUMPING DOWN ........................................................................7

Model

Power supply

Pipe length and height difference 

*1, *2, *3, *4, *5, *6

Rated Voltage

Frequency Max. pipe length per indoor 

unit / for multi-system

Max. height difference

Max. no. of bends per in-

door unit / for multi system

Refrigerant adjustment A 

*7

MXZ-3C24NA

MXZ-3C30NA

MXZ-4C36NA

208 / 230 V

60 Hz

82 ft (25 m) / 230 ft (70 m)

49 ft (5 m)

25 / 70

1.08 oz each 5 ft (20 g/m)

*1 Never  use  pipes  with  thickness  less  than  specified.  The  pressure  resist

-

ance will be insufficient.

*2 Use a copper pipe or a copper-alloy seamless pipe.

*3 Be careful not to crush or bend the pipe during pipe bending.

*4 Refrigerant pipe bending radius must be 4 in. (00 mm) or more.

*5 Insulation material : Heat resisting foam plastic 0.045 specific gravity

*6 Be sure to use the insulation of specified thickness. Excessive thickness 

may cause incorrect installation of the indoor unit and insufficient thickness 

may cause dew drippage.

*7 If pipe length exceeds 98 ft (30 m), additional refrigerant (R410A) charge 

is required. (No additional charge is required for pipe length less than 98 ft 

(30 m).)

  Additional refrigerant (ft)  = A ×  (pipe length (ft) – 98)

5

  Additional refrigerant (m) = A × (pipe length (m) – 30)

WG79A615H01_en.indd   1

2014/07/30   17:18:12

Содержание MXZ-3C30NA

Страница 1: ...décrit que l installation de l appareil extérieur Lors de l installation de l appareil intérieur consultez la notice d installation de cet appareil Toute altération structurelle requise pour l installation doit être conforme aux exi gences du code du bâtiment local Manual de instalación Para el INSTALADOR En este manual sólo se describe la instalación de la unidad exterior Para instalar la unidad ...

Страница 2: ...6 times more than R22 Not using appropriate tools or materials and incomplete installation could cause the pipes to burst or injury n When pumping down the refrigerant stop the compressor before dis connecting the refrigerant pipes If the refrigerant pipes are disconnected while the compressor is running and the stop valve is open air could be drawn in and the pressure in the re frigeration cycle ...

Страница 3: ...s required 2 Front blowing side open As long as space indicated in the figure is provided it is allowed to install the unit where obstacles are behind and on the sides of the unit No ob stacle above the unit FREE SPACE REQUIRED AROUND OUTDOOR UNIT Service space When installing the unit in an area that is enclosed with walls such as a verandah be sure to have enough space as shown below In this cas...

Страница 4: ... hole sleeve 1 L Soft PVC hose 19 32 in 15 mm inner diameter or hard PVC pipe VP16 for drain socket 1 1 Note Place indoor outdoor unit connecting wire B and power supply cord A at least 3 ft 1 m away from the TV antenna wire The Q ty for B to K in the above table is quan tity to be used per indoor unit More than 3 15 16 in 100 mm Open as a rule More than 19 11 16 in 500 mm if the front and both si...

Страница 5: ...unit 8 Connect power supply cord A 9 Close the service panel securely Make sure that 3 2 PIPE CON NECTION is completed Connecting order Connect the terminal block in following order A B C D P CONNECTING WIRES AND CONNECTING GROUND WIRE Use solid conductor Min AWG14 or stranded conductor Min AWG14 Use double insulated copper wire with 600 V insulation Use copper conductors only Follow local electri...

Страница 6: ...ice port cap of stop valve on the side of the outdoor unit gas pipe The stop valves are fully closed and covered in caps in their initial state 2 Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outdoor unit 3 Run the vacuum pump Vacuumize for more than 15 minutes 4 Check the vacuum with gauge manifold valve then close gauge manifold valve and ...

Страница 7: ... 3 TEST RUN Be sure to also check the following The outdoor unit is not faulty When the outdoor unit fails LED outdoor unit control panel blinks Both the gas and liquid stop valves are completely open Test runs of the indoor units should be performed individually See the installation manual coming with the indoor unit and make sure all the units operate properly If the test run with all the units ...

Страница 8: ...lain to the user how to use the air conditioner how to use the remote controller how to remove the air filters how to remove or put the remote controller in the remote controller holder how to clean precautions for operation etc Recommend the user to read the OPERATING INSTRUCTIONS carefully 5 PUMPING DOWN When relocating or disposing of the air conditioner pump down the system following the proce...

Страница 9: ...uffage à ventilation chauffage d appoint poêle etc des substances toxiques peuvent se dégager n Utiliser les outils et l équipement de tuyauterie adaptés à l installation La pression du réfrigérant R410A est 1 6 fois supérieure à celle du R22 L utilisation d outils ou d équipements inadaptés et une installation incomplète peuvent provoquer l éclatement des tuyaux et blesser quelqu un n Pendant l o...

Страница 10: ...observer les instructions ci dessous N installez jamais l unité externe dans un endroit où le côté présentant l entrée la sortie d air risque d être directement exposé au vent Pour protéger l unité externe du vent installez la de façon à ce que l entrée d air soit face au mur Pour éviter toute exposition au vent il est recommandé d installer un écran de protection du côté de la sortie d air de l u...

Страница 11: ...r un mur contenant des métaux de l étain p ex ou un treillis métallique utiliser un morceau de bois traité d une épais seur de 25 32 po 20 mm minimum entre le mur et la tuyauterie ou isoler la tuyauterie en lui appliquant 7 à 8 couches de ruban isolant en vinyle Pour utiliser la tuyauterie existante effectuer un cycle COOL REFROI DISSEMENT de 30 minutes et lancer l aspiration avant de procéder à l...

Страница 12: ...ALIMENTATION ÉLECTRIQUE ET CÂBLE DE MISE À LA TERRE Utiliser un conducteur massif ou toronné min AWG12 Utiliser des conducteurs en cuivre uniquement Respecter le code électrique local AVERTISSEMENT Utiliser le câble de connexion conforme aux normes techniques pour raccorder les unités interne et externe et fixer le câble fermement sur la bloc de sortie de façon que le côté raccordement de ce derni...

Страница 13: ... ouverture de service pour recréer les conditions d origine 10 Test de contrôle des fuites 3 2 RACCORDEMENT DES TUYAUX 1 Appliquez une fine couche d huile réfrigérante G sur les embouts évasés des tuyaux ainsi que sur les raccords de tuyau de l appareil extérieur 2 Alignez la partie médiane du tuyau sur les raccords de tuyau de l appareil extérieur et serrez les écrous évasés à la main de 3 à 4 to...

Страница 14: ...t de l appareil intérieur est contrôlé par l appareil extérieur Lors de la détection l appareil intérieur s arrête automatiquement Il ne s agit pas d un dysfonc tionnement 4 2 RECHARGE DE GAZ Charger du gaz pour l appareil 1 Relier la bouteille de gaz sur l orifice de service du robinet d arrêt 2 Effectuer la purge d air de la canalisation ou du flexible venant du cylindre de réfrigérant 3 Charger...

Страница 15: ...e liquide de l unité externe 4 Enclenchez le disjoncteur 5 Démarrez le fonctionnement en mode COOL REFROIDISSEMENT sur tous les appareils intérieurs 6 Lorsque le manomètre indique 0 1 à 0 psi jauge 0 05 à 0 MPa fermez complètement le robinet d arrêt du côté du tuyau de gaz de l appareil extérieur et arrêtez le système Reportez vous au manuel d installation de l appareil intérieur pour la méthode d...

Страница 16: ...fallos mecánicos malfuncionamiento del sistema o averías en la unidad En el peor de los casos esto podría llegar a ser un serio impedimento para garantizar el uso seguro del producto n No descargue el refrigerante en el ambiente Si se producen fugas de refrige rante durante la instalación ventile la habitación Si el refrigerante entra en contacto con una llama podría generarse gas nocivo La pérdid...

Страница 17: ...e las instrucciones siguientes No instale nunca la unidad exterior en un lugar en el que el lado de entra da salida de aire quede expuesto directamente al viento Para evitar la exposición al viento instale la unidad exterior con el lado de entrada de aire hacia la pared Para evitar la exposición al viento se recomienda instalar una placa de flectora en el lado de salida de aire de la unidad exteri...

Страница 18: ... y ambos lados están abiertos Después de la prueba de fugas aplique material aislante de modo que no queden huecos Cuando los tubos deban instalarse en una pared con contenido metálico placas de latón o rejillas metálicas ponga un trozo de madera tratada químicamente de 25 32 pulg 20 mm o más de grosor entre la pared y los tubos o envuelva los tubos con 7 u 8 vueltas de cinta aislante de vinilo Pa...

Страница 19: ...conductores de cobre Siga la normativa eléctrica local CABLE DE ALIMENTACIÓN Y CABLE DE TIERRA Utilice un conductor sólido o trenzado con un calibre mín AWG12 Use únicamente conductores de cobre Siga la normativa eléctrica local ATENCIÓN Conecte las unidades interior y exterior con el cable de conexión normalizado destinado a este fin y sujete bien el cable al panel de terminales de modo que no qu...

Страница 20: ...a de servicio de la válvula de retención situada en el lado de la tubería de gas de la unidad exterior Inicialmente las válvulas de retención están completamente cerradas y cubiertas con sus tapas 2 Conecte la válvula colectora de manómetro y la bomba de vacío al puerto de servicio de la válvula de retención en el lado de la tubería del gas de la unidad exterior 3 Ponga en funcionamiento la bomba ...

Страница 21: ...fectuosa Cuando se produce un error en la unidad exterior los indicadores luminosos del panel de control de la unidad exterior parpadean Las válvulas de retención de gas y líquido permanecen completamente abiertas Deben realizarse pruebas de funcionamiento de las unidades interiores de forma individual Consulte el manual de instalación que acompaña a la unidad interior y asegúrese de que todas las...

Страница 22: ...a rillo 3 verde Iluminado No ilumi nado Iluminado Finalizado corregido satisfactoriamente Parpadea una vez Parpadea una vez Parpadea una vez Imposible de corregir Otras indicaciones Consulte las PRECAU CIONES DE SEGURIDAD CUANDO EL INDICADOR PARPADEA situadas de trás del panel de servicio 4 4 EXPLICACIÓN PARA EL USUARIO Basándose en el MANUAL DE INSTRUCCIONES explique al usuario cómo utilizar el e...

Страница 23: ...A4 tombo blank indd 1 12 18 2006 9 45 16 AM ...

Страница 24: ...WG79A615H01 HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WG79A615H01_cover4 indd 2 2014 07 30 17 19 34 ...

Отзывы: