OPERATING PROCEDURE
PHOTOS
5. Removing the outdoor fan motor
(1) Remove the service panel, the top panel and the cabi-
net (Refer to 1).
(2) Disconnect the power supply and indoor/outdoor con-
necting wire.
(3) Disconnect the connectors for outdoor fan motor.
(4) Remove the propeller fan nut.
(5) Remove the propeller fan.
(6) Remove the screws fixing the fan motor.
(7) Remove the fan motor.
6. Removing the compressor and the 4-way valve
(1) Remove the service panel, the top panel and the cabi-
net (Refer to 1).
(2) Disconnect the power supply and indoor/outdoor con-
necting wire and remove the back panel (Refer to 1).
(3) Remove the inverter assembly (Refer to 2).
(4) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure
gauge shows 0 kg/cm
2
(0 MPa).
(5) Detach the brazed part of the suction and the dis-
charge pipe connected with compressor.
(6) Remove the nuts of compressor legs.
(7) Remove the compressor.
(8) Detach the brazed part of pipes connected with 4-way
valve.
52
Defrost
thermistor
(RT61)
Ambient
temperature
thermistor
(RT65)
Photo 9
Photo 8
Screws of the fan motor
Outdoor heat
exchanger
temperature
thermistor (RT68)
Propeller fan
Brazed parts of 4-way valve
Propeller fan nut
Photo 7
Photo 10
Suction pipe brazed part
Discharge pipe brazed part
Compressor nuts
OBH709A