45
The other cases
Check of outdoor refrigerant circuit
Indoor unit does not operate. (different operating models in multi system)
• When you try to run 2 indoor units simultaneously, one for cooling and the other for heating, the unit which transmits signal to
the outdoor unit first decides the operation mode.
• When the above situation occurs, set all the indoor units to the same mode, turn OFF the indoor units, then turn them back
ON.
• Though the top of the indoor unit sometimes gets warm, this does not mean malfunction.
The reason is that the refrigerant gas continuously flows into the indoor unit even while it is not operating.
Check of bus-bar voltage
•Check the voltage of power supply.
•Con
fi
rm outdoor unit failure mode
recall function. (Refer to 11-2.2.)
Blink 5 times
Con
fi
rm LED1 indication lamp on the
outdoor control P.C. board.
Replace the power P.C.
board.
Blink 9 times
Replace the outdoor
control P.C. board.
Turn OFF the breaker before removing P.C. board.
Con
fi
rm LED1 indication lamp
on the outdoor control P.C.
board.
Turn ON the breaker.
Start operation.
Blink 6 times
Replace the outdoor control
P.C. board .
Lighting
Replace the outdoor control
P.C. board.
Blink 9 times
Replace the power P.C.
board.
Con
fi
rm LED1 indication lamp
on the outdoor control P.C.
board.
Turn ON the breaker.
Start operation.
Normal
Lighting
Lighting
MXZ-3HJ50VA
Has the operation stopped
during pump down?
Was the operation started with
the stop valve closed, and was
it opened during operation?
No
Yes
The operation has stopped to pre-
vent the diesel explosion caused by
air trapped in the refrigerant circuit.
Close the stop valve, and disconnect
the power plug or turn the breaker
OFF.
The unit occasionally stops when the
stop valve is opened or closed during
operation. Open the stop valve and
start the cooling operation again.
Yes
No
The refrigerant gas amount may be
60% or less than the normal amount.
Identify where the gas is leaking from,
and
fi
x the leak.
CAUTION : Do not start the opera-
tion again to prevent
hazards.
OBH709A