background image

Split-type Air-Conditioner

MXZ-2HJ40VA

Türkçe

English

Installation Manual

 

For INSTALLER

• 

This manual only describes the installation of outdoor unit.

  When installing the indoor unit, refer to the installation manual of indoor unit.

Kurulum Kılavuzu

 

TESİSATÇI İÇİN

•  Bu kılavuzda yalnızca dış ünitenin kurulumu açıklanmaktadır. 

  İç ünite kurulum işlemini yaparken iç ünite kurulum kılavuzuna bakın.

English is original.

Orijinalin çevirisi

BH79A129H01_en-tr_cover.indd   1

10/31/2014   9:57:45 AM

Содержание MXZ-2HJ40VA

Страница 1: ...s the installation of outdoor unit When installing the indoor unit refer to the installation manual of indoor unit Kurulum Kılavuzu TESİSATÇI İÇİN Bu kılavuzda yalnızca dış ünitenin kurulumu açıklanmaktadır İç ünite kurulum işlemini yaparken iç ünite kurulum kılavuzuna bakın English is original Orijinalin çevirisi ...

Страница 2: ... leak after installation has been completed If refrigerant gas leaks indoors and comes into contact with the flame of a fan heater space heater stove etc harmful substances will be generated n Use appropriate tools and piping materials for installation The pressure of R410A is 1 6 times more than R22 Not using appropriate tools or materials and incomplete installation could cause the pipes to burs...

Страница 3: ... inner diameter or hard PVC pipe VP16 for drain socket 1 1 Note 1 Place indoor outdoor unit connecting wire B and power supply cord A at least 1 m away from the TV antenna wire The Q ty for B to K in the above table is quan tity to be used per indoor unit Units should be installed by licensed contractor according to local code requirements More than 100 mm More than 100 mm More than 200 mm if ther...

Страница 4: ...r unit connecting wire B and power supply cord A with the cable clamps 7 Close the service panel securely Make sure that 3 2 PIPE CONNEC TION is completed After making connections between both power supply cord A and indoor outdoor unit connecting wire B be sure to fix both cable and wire with cable clamps Indoor outdoor unit connecting wire OUTDOOR UNIT 35 mm 15 mm Lead wire Terminal block UNIT U...

Страница 5: ... cap of service port to obtain the initial status 10 Leak test WARNING When installing the unit securely connect the refrigerant pipes before starting the compressor CAUTION When there are the ports which are not used make sure their nuts are tightened securely Stop valve for GAS Stop valve cap Torque 19 6 to 29 4 N m 200 to 300 kgf cm Gauge manifold valve for R410A Compound pressure gauge for R41...

Страница 6: ...he test run one by one Make sure that the following is done Power is supplied to the unit Stop valves are open About the restart protective mechanism Once the compressor stops the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner When relocating or disposing of the air conditioner pump down the system following the procedure below so...

Страница 7: ...tuutettu EU edustaja joka on valtuutettu laatimaan teknisen eritelmän on mainittu alla Наш упълномощен представител в ЕС който е упълномощен да състави техническото досие е както следва MITSUBISHI ELECTRIC EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDGE MIDDLESEX UB8 1QQ U K Yoji SAITO Product Marketing Director Issued 9 October 2014 Tomoyuki MIWA THAILAND Manager Quality Assurance Department MIT...