*1
En-5
1-5. INSTALLATION DIAGRAM
Units should be installed by licensed contractor according to local code
requirements.
More than
100 mm
More than 100 mm
More than 200 mm if there are
obstacles to both sides
Open as a rule
More than 500 mm if the back,
both sides and top are open
More than 350 mm
Outdoor unit installation
(Unit: mm)
285
Air inlet
150
500
Air inlet
4-10 × 21 Oval holes
304~325
344.5
Air outlet
800
Open as a rule
More than 500 mm
if the front and both
sides are open
*1 The manufacturing year and month is indicated on the spec name plate.
1-6. DRAIN PIPING FOR OUTDOOR UNIT
Please perform the drain piping work only when draining from one place.
1) Provide drain piping before indoor and outdoor piping connection.
2) Connect the soft PVC hose (L) I.D.15 mm as shown in the illustration.
3) Make sure to provide drain piping with a downhill grade for easy drain flow.
Note:
Install the unit horizontally.
Do not use the drain socket (1) in the cold regions. Drain may freeze and it
makes the fan stop.
The outdoor unit produces condensate during the heating operation. Select
the installation place to ensure to prevent the outdoor unit and/or the grounds
from being wet by drain water or damaged by frozen drain water.
(1) Drain socket
(L) Soft PVC hose
When the piping is to be attached to a wall containing
metals (tin plated) or metal netting, use a chemically
treated wooden piece 20 mm or thicker between the wall
and the piping or wrap 7 to 8 turns of insulation vinyl tape
around the piping.
To use existing piping, perform COOL operation for 30
minutes and pump down before removing the old air
conditioner. Remake flare according to the dimension for
new refrigerant.
After the leak test, apply insulating material tightly so
that there is no gap.
WARNING
To avoid risk of fire, embed or protect the refrigerant
piping.
External damage on the refrigerant piping can be
cause of fire.
ACCESSORIES
Check the following parts before installation.
(1) Drain socket
1
PARTS TO BE PROVIDED AT YOUR SITE
(A) Power supply cord*2
1
(B) Indoor/outdoor unit connecting wire*2
1
(C) Extension pipe
1
(D) Wall hole cover
1
(E) Piping tape
1
(F)
Extension drain hose
(or soft PVC hose, 15 mm inner diameter or
hard PVC pipe VP16)
1
(G) Refrigeration oil
Little
amount
(H)
Putty
1
(I)
Pipe fixing band
2 to 7
(J) Fixing screw for (I)
2 to 7
(K) Wall hole sleeve
1
(L)
Soft PVC hose, 15 mm inner diameter or hard
PVC pipe VP16 for drain socket (1)
1
Note:
*2 Place indoor/outdoor unit connecting wire (B) and power supply cord (A)
at least 1 m away from the TV antenna wire.
The “Q’ty” for (B) to (K) in the above table is quantity to be used per indoor unit.