1-2. SPECIFICATIONS

Model

Power supply *1

Wire specifications *2

Pipe length and height difference *3, *4, *5, 

*6, *7, *8

Outdoor Noise level

Rated 

Voltage

Fre-

quency

Breaker 

capacity

Power 

supply

Indoor/outdoor 

connecting wire

Max. pipe 

length per in-

door unit / for 

multi-system

Max. height 

difference *9

Max. no. of 

bends per in

-

door unit / for 

multi-system

Cooling

Heating

MXZ-2HA40VF

220-230-

240 V

50 Hz

15 A

3-core 

2.0 mm

2

4-core 

1.0/1.5 mm

2

20 m / 30 m

15 m

20 / 30

44 dB (A) 50 dB (A)

MXZ-2HA50VF

47 dB (A) 51 dB (A)

 

CAUTION

(Could lead to serious injury in particular environments when operated incorrectly.)

n

  Install an earth leakage breaker depending on the installation place.

  If an earth leakage breaker is not installed, it could cause electric shock.

n

  Perform the drainage/piping work securely according to the instal-

lation manual.

  If there is defect in the drainage/piping work, water could drop from the 

unit, soaking and damaging household goods.

n

  Do not touch the air inlet or the aluminum fins of the outdoor unit.

  This could cause injury. 

n

  Do not install the outdoor unit where small animals may live.

  If small animals enter and touch the electric parts inside the unit, it could 

cause a malfunction, smoke emission, or fire. Also, advise user to keep 

the area around the unit clean. 

n

  Do not operate the air conditioner during interior construction and 

finishing work, or while waxing the floor. 

  Before operating the air conditioner, ventilate the room well after such work 

is performed. Otherwise, it may cause volatile elements to adhere inside 

the air conditioner, resulting in water leakage or scattering of dew.

1-3. SELECTING OPTIONAL DIFFERENT-DIAMETER JOINTS

If the diameter of connection pipe does not match the port size of outdoor unit, use optional different-diameter joints according to the following table.

(Unit: mm (inch))

Port size of outdoor unit

Optional different-diameter joints (port size of outdoor unit → diameter of connection pipe)

MXZ-2HA

Liquid / Gas

9.52 (3/8) 

 12.7 (1/2) : MAC-A454JP-E

Refer to the installation manual of indoor unit for the diameter of connection pipe of indoor unit.

A, B UNIT

6.35 (1/4) / 9.52 (3/8)

*1  Connect to the power switch which has a gap of 3 mm or more when open to interrupt the 

source power phase. (When the power switch is shut off, it must interrupt all phases.)

*2  Use wires in conformity with design 60245 IEC 57. Use the indoor/outdoor connecting wire in 

conformity with the wire specifications specified in the installation manual of the indoor unit.

*3  Never use pipes with thickness less than specified. The pressure resistance will be insufficient.

*4  Use a copper pipe or a copper-alloy seamless pipe.

*5  Be careful not to crush or bend the pipe during pipe bending.

*6  Refrigerant pipe bending radius must be 100 mm or more.

*7  Insulation material : Heat resisting foam plastic 0.045 specific gravity

*8  Be sure to use the insulation of specified thickness. Excessive thickness may cause incorrect 

installation of the indoor unit and insufficient thickness may cause dew drippage.

*9  If the outdoor unit is installed higher than the indoor unit, max. height difference is reduced 

to 10 m.

1-4. SELECTING THE INSTALLATION LOCATION

•  Where it is not exposed to strong wind.

•  Where airflow is good and dustless.

•  Where rain or direct sunshine can be avoided as much as possible.

•  Where neighbours are not annoyed by operation sound or hot air.

•  Where rigid wall or support is available to prevent the increase of opera

-

tion sound or vibration.

•  Where there is no risk of combustible gas leakage.

•  When installing the unit, be sure to secure the unit legs.

•  Where it is at least 3 m away from the antenna of TV set or radio. Opera

-

tion of the air conditioner may interfere with radio or TV reception in areas 

where reception is weak. An amplifier may be required for the affected 

device.

•  Install the unit horizontally.

•  Please install it in an area not affected by snowfall or blowing snow. In 

areas with heavy snow, please install a canopy, a pedestal and/or some 

baffle boards.

Note:

It is advisable to make a piping loop near outdoor unit so as to reduce 

vibration transmitted from there.

Note: 

When operating the air conditioner in low outside temperature, be sure 

to follow the instructions described below.

•  Never install the outdoor unit in a place where its air inlet/outlet side 

may be exposed directly to wind.

•  To prevent exposure to wind, install the outdoor unit with its air inlet 

side facing the wall.

•  To prevent exposure to wind, it is recommended to install a baffle board 

on the air outlet side of the outdoor unit.

Avoid the following places for installation where air conditioner trouble 

is liable to occur.

•  Where flammable gas could leak.

•  Where there is much machine oil.

•  Where oil is splashed or where the area is filled with oily smoke (such 

as cooking areas and factories, in which the properties of plastic could 

be changed and damaged).

•  Salty places such as the seaside.

•  Where sulfide gas is generated such as a hot spring.

•  Where there is high-frequency or wireless equipment.

•   Where there is emission of high levels of VOCs, including phthalate 

compounds, formaldehyde, etc., which may cause chemical cracking.

•  The appliance shall be stored so as to prevent mechanical damage 

from occurring.

Model

Maximum amount 

of refrigerant 

charge

Factory-charged 

refrigerant amount

MXZ-2HA40VF

0.9 kg

0.9 kg

MXZ-2HA50VF

VG79A989H01_en.indd   2

2018/09/27   15:03:35

Содержание MXZ-2HA40VF

Страница 1: ...nstalação Para o INSTALADOR Este manual descreve apenas a instalação da unidade exterior Quando proceder à instalação da unidade interior consulte o manual de instalação da unidade interior Installationshåndbog Til INSTALLATØREN Denne håndbog beskriver kun hvordan udendørsenheden installeres Vedrørende installation af indendørsenheden henvises til installationshåndbogen for indendørsenheden Instal...

Страница 2: ...лі а потім мову BG Посетете горепосочения уебсайт за да изтеглите ръководства като изберете име на модел и след това език PL Odwiedź powyższą stronę internetową aby pobrać instrukcje wybierz nazwę modelu a następnie język CS Příručky naleznete ke stažení na internetové stránce zmíněné výše poté co zvolíte model a jazyk SK Na webovej stránke vyššie si môžete stiahnuť návody Vyberte názov modelu a z...

Страница 3: ...use electric shock or fire If loose parts are found on the power supply plug replace it n Attach the electrical cover to the indoor unit and the service panel to the outdoor unit securely If the electrical cover of the indoor unit and or the service panel of the outdoor unit are not attached securely it could result in a fire or an electric shock due to dust water etc n When installing relocating ...

Страница 4: ...4 Use a copper pipe or a copper alloy seamless pipe 5 Be careful not to crush or bend the pipe during pipe bending 6 Refrigerant pipe bending radius must be 100 mm or more 7 Insulation material Heat resisting foam plastic 0 045 specific gravity 8 Be sure to use the insulation of specified thickness Excessive thickness may cause incorrect installation of the indoor unit and insufficient thickness m...

Страница 5: ... in a sufficiently large space without depressions 1 4 1 Minimum installation area for Outdoor units If you unavoidably install a unit in a space where all four sides are blocked or there are depressions confirm that one of these situations A B or C is satisfied Note These countermeasures are for keeping safety not for specification guarantee A Secure sufficient installation space minimum installa...

Страница 6: ...t locally added refrigerant Install the indoor unit so that the height from the floor to the bottom of the indoor unit is h0 for wall mounted 1 8 m or more for ceiling suspended cassette and ceiling concealed 2 2 m or more There are restrictions in installation height for each model so read the installation manual for the particular unit M kg Amin m 1 0 3 1 5 4 5 2 0 6 2 5 7 5 3 0 9 3 5 12 4 0 15 ...

Страница 7: ...er 1 Drain socket L Soft PVC hose When the piping is to be attached to a wall containing metals tin plated or metal netting use a chemically treated wooden piece 20 mm or thicker between the wall and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping To use existing piping perform COOL operation for 30 minutes and pump down before removing the old air conditioner Remake fla...

Страница 8: ...ION 3 1 PRECAUTIONS FOR DEVICES THAT USE R32 REFRIGERANT Use ester oil ether oil alkylbenzene oil small amount as the refrigeration oil applied to the flared sections Use C1220 copper phosphorus for copper and copper alloy seamless pipes to connect the refrigerant pipes Use refrigerant pipes with the thicknesses specified in the table to the below Make sure the insides of the pipes are clean and d...

Страница 9: ... differs depending the models and the capacities of indoor units Indoor unit capacity 25 50 Liquid pipe size ø6 35 Gas pipe size ø9 52 Use tightening torque table above as a guideline for indoor unit side union joint section and tighten using two wrenches Excessive tightening dam ages the flare section 1 Apply a thin coat of refrigeration oil G to the flared ends of the pipes and the pipe connecti...

Страница 10: ...ed This may cause gas leak Service port Charge hose for R32 R410A Body Close Open Control valve A When attaching the control valve to the service port make sure that the valve core is in closed position and then tighten part A Do not tighten part A or turn the body when valve core is in open position Service port cap Torque 13 7 to 17 7 N m 140 to 180 kgf cm Charge hose for R32 R410A 4 2 GAS CHARG...

Страница 11: ...e Make sure that the following is done Power is supplied to the unit Stop valves are open About the restart protective mechanism Once the compressor stops the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner When relocating or disposing of the air conditioner pump down the system following the procedure below so that no refrigerant ...

Страница 12: ...лищни търговски и леки промишлени условия erklærer et fullstendig ansvar for undernevnte klimaanlegg og varmepumper ved bruk i boliger samt kommersielle og lettindustrielle miljøer vakuuttaa täten yksinomaisella vastuullaan että jäljempänä kuvatut asuinrakennuksiin pienteollisuuskäyttöön ja kaupalliseen käyttöön tarkoitetut ilmastointilaitteet ja lämpöpumput настоящим заявляет и берет на себя искл...

Страница 13: ...irezionale Colleoni Palazzo Sirio Ingresso 1 Viale Colleoni 7 20864 Agrate Brianza MB Italy Norwegian Branch Gneisveien 2D 1914 Ytre Enebakk Norway Portuguese Branch Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Spanish Branch Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scandinavian Branch Hammarbacken 14 P O Box 750 SE 19127 Sollentuna Sweden UK Branch Trave...

Отзывы: