OPERATING PROCEDURE
PHOTOS
3
. Removing the fan motor
(1) Remove the service panel (Photo 1).
(2) Disconnect the power supply and indoor/outdoor connect-
ing wire.
(3) Remove the top panel, the cabinet, and the back panel
(Photo 1, 2, 3).
(4) Disconnect connectors CN712, CNF1, CNTH1, CNTH2,
CN63H, CN791, CN792, CN793, CN794 (
MXZ-4F72VF
),
CN797 on the outdoor control P.C. board and disconnect
the relay connector of the compressor lead wire.
(5) Remove the screws of the electrical box assembly, and
remove the electrical box assembly (Photo 4).
(6) Remove the propeller fan.
(7) Remove the fan motor.
Photo 8
4. Removing the compressor and the 4-way valve
(1) Remove the service panel (Photo 1).
(2) Disconnect the power supply and indoor/outdoor connect-
ing wire.
(3) Remove the top panel, the cabinet, and the back panel
(Photo 1, 2, 3).
(4) Recover gas from the refrigerant circuit.
NOTE
: Recover gas from the pipes until the pressure
gauge shows 0 kg/cm
2
(0 MPa).
(5) Disconnect the outdoor control P.C. board connectors:
CN712, CNF1, CNTH1, CNTH2, CN63H, CN791,CN792,
CN793, CN794 (
MXZ-4F72VF
), CN797.
(6) Disconnect the compressor lead wire from the terminal of
the compressor (U, V, W).
(7) Remove the screws of the electrical box assembly, and
remove the electrical box assembly (Photo 4).
(8) Remove the propeller fan.
(9) Remove the sound proof felt *1, *2 and *3 (
MXZ-3F54VF
).
NOTE
: Before removing the sound proof felt, remove
the hook-and-loop fastener of the top felt by the
power receiver.
(10) Remove the screws of the separator, and remove the
separator.
(11) Detach the brazed parts of the compressor suction and
discharge pipes.
(12) Remove the compressor nuts and remove the compres-
sor.
(13) Detach the brazed parts of the 4-way valve and pipe.
Sound
proof
felt *2
R.V. coil
4-way valve
LEV coil R
Expansion valve R
Suction pipe
brazed part
Discharge pipe
brazed part
Compressor nuts
Power receiver
Hook-and-loop
fastener
91
Photo 9
Photo 10
Screws of the outdoor fan motor
Propeller fan Propeller
fan nut
Separator Sound
proof felt *1
Sound
proof felt *3
(
MXZ-
3F54VF
)
OBH790
Содержание MXZ-2F33VF
Страница 22: ...22 OUTLINES AND DIMENSIONS 6 MXZ 2F33VF MXZ 2F42VF MXZ 2F53VF MXZ 2F53VFH Unit mm OBH790 ...
Страница 25: ...25 WIRING DIAGRAM 7 MXZ 2F33VF E1 ET1 MXZ 2F42VF E1 ET1 MXZ 2F53VF E1 ET1 OBH790 ...
Страница 26: ...26 MXZ 2F53VFH E1 OBH790 ...
Страница 27: ...27 MXZ 3F54VF E1 ET1 MXZ 3F68VF E1 ET1 OBH790 ...
Страница 28: ...28 MXZ 4F72VF E1 ET1 OBH790 ...
Страница 93: ...93 OBH790 ...