30
Stop valve
(with strainer #100)
LEV A
LEV B
Compressor
Defrost
thermistor RT61
Distributor
Muffler
4-way valve
Indoor unit
A
Indoor unit
B
Indoor unit
A
Indoor unit
B
Capillary tube
Capillary tube
Capillary tube
Strainer
#100
Stop valve
(with strainer #100)
R.V. coil
OFF
ON
Refrigerant flow in cooling
Refrigerant flow in heating
Ambient
temperature
thermistor
RT65
Outdoor heat
exchanger
temperature
thermistor RT68
FAN-OUT
HEX-OUT
Discharge
temperature
thermistor RT62
Stop valve
(with service port)
Stop valve
(with service port)
Sub muffler
UNIT: mm
MXZ-2F42VF MXZ-2F53VF MXZ-2F53VFH
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b)
20 m
Total piping length (a+b)
30 m
Bending point for each unit
30
Total bending point
20
It is irrelevant which unit is higher.
a
b
Outdoor
unit
Indoor
units
15 m
10 m
15 m
Max.
Height
difference
UNIT: mm (inch)
Outdoor unit union diameter
For
Indoor unit A
Liquid
6.35(1/4)
Gas
9.52(3/8)
Indoor unit B
Liquid
6.35(1/4)
Gas
9.52(3/8)
ADDITIONAL REFRIGERANT CHARGE
Outdoor unit
precharged
(g)
Refrigerant piping length (one way, 2 unit total)
30 m
1,200
0
Refrigerant pipe diameter is different according to indoor unit to be
connected. When using extension pipes, refer to the right table.
For
MXZ-2F53VF
and
MXZ-2F53VFH
, when diameter of refriger-
ant pipe is different from that of outdoor unit union, use optional
Different-diameter pipe.
For further information on Different-diameter pipe, refer to "PARTS
CATALOG"
OBH790
Содержание MXZ-2F33VF
Страница 22: ...22 OUTLINES AND DIMENSIONS 6 MXZ 2F33VF MXZ 2F42VF MXZ 2F53VF MXZ 2F53VFH Unit mm OBH790 ...
Страница 25: ...25 WIRING DIAGRAM 7 MXZ 2F33VF E1 ET1 MXZ 2F42VF E1 ET1 MXZ 2F53VF E1 ET1 OBH790 ...
Страница 26: ...26 MXZ 2F53VFH E1 OBH790 ...
Страница 27: ...27 MXZ 3F54VF E1 ET1 MXZ 3F68VF E1 ET1 OBH790 ...
Страница 28: ...28 MXZ 4F72VF E1 ET1 OBH790 ...
Страница 93: ...93 OBH790 ...