88
&KHFNRI59FRLO
7KHFRROLQJRSHUDWLRQRUKHDWLQJRSHUDWLRQGRHVQRWRSHUDWH
No
Yes
No
Yes
No
Yes
No
Yes
1. Disconnect the lead wire leading to the compressor.
2. 3 minutes after turning ON the power supply, start EMERGENCY
OPERATION in COOL mode.
Is there voltage of 208/230 V AC between pin1
and pin2 at connector CN712?
Turn OFF the power supply.
Disconnect the connector CNAC2.
Replace the 4-way valve.
Replace the outdoor
control P.C. board.
Replace the R.V. coil.
Is there voltage 208/230 V AC
between the pin1 and pin3 at
connector CNAC?
Replace the outdoor
power P.C. board.
Is there normal resistance
to R.V. coil? (Refer to 11-5.)
1. Disconnect the lead wire leading to the compressor.
2. 3 minutes after turning ON the power supply, start EMERGENCY
OPERATION in HEAT mode.
Is there voltage of 208/230 V AC between pin1
and pin2 at connector CN712?
Replace the 4-way valve.
Replace the outdoor control P.C. board.
:KHQFRROLQJRSHUDWLRQGRHVQRWZRUN
:KHQKHDWLQJRSHUDWLRQGRHVQRWZRUN
CNAC
CN712
Outdoor control
P.C. board
CNAC2
Outdoor power
P.C. board
OBH702G
Содержание MXZ-2C20NA2-U1
Страница 19: ...19 MXZ 4C36NA MXZ 4C36NA2 Unit inch mm Lock nut Conduit plates Conduit connector OBH702G ...
Страница 21: ...21 MXZ 2C20NAHZ MXZ 2C20NAHZ2 Unit inch mm Lock nut Conduit connector Conduit plate OBH702G ...
Страница 24: ...24 MXZ 3C24NA MXZ 3C30NA OBH702G ...
Страница 25: ...25 MXZ 3C24NA2 MXZ 3C30NA2 OBH702G ...
Страница 26: ...26 MXZ 4C36NA OBH702G ...
Страница 27: ...27 MXZ 4C36NA2 OBH702G ...
Страница 29: ...29 MXZ 5C42NA2 OBH702G ...
Страница 30: ...30 MXZ 2C20NAHZ OBH702G ...
Страница 31: ...31 MXZ 2C20NAHZ2 OBH702G ...
Страница 32: ...32 MXZ 3C24NAHZ MXZ 3C30NAHZ OBH702G ...
Страница 33: ...33 MXZ 3C24NAHZ2 MXZ 3C30NAHZ2 OBH702G ...