81
7DEOHRIRXWGRRUXQLWIDLOXUHPRGHUHFDOOIXQFWLRQ
The left lamp of
OPERATION IN-
DICATOR lamp
(Indoor unit)
Abnormal point
(Failure mode/protection)
LED indication
(Outdoor P.C.
board)
Condition
Remedy
Indoor/
outdoor unit
failure mode
recall function
LED 1
LED 2
OFF
None (Normal)
Lit
Lit
2-time blink
Outdoor power system
Lit
Lit
Overcurrent protection cut-out operates
3 consecutive times within 1 minute after
the compressor gets started, or converter
protection cut-out or bus-bar voltage
protection cut-out operates 3 consecutive
times within 3 minutes after startup.
• Check the connection of the com-
pressor connecting wire.
• Refer to 11-6.
"How to check inverter/compres-
sor".
• Check the stop valve.
ż
3-time blink
Discharge temperature thermistor
Lit
Once
A thermistor shorts or opens during
compressor running.
• Refer to 11-6. "Check of outdoor
thermistors".
ż
Defrost thermistor
Lit
Once
Ambient temperature thermistor
Lit
Twice
Fin temperature thermistor
Lit
3 times
P.C. board temperature thermistor
Lit
4 times
• Replace the outdoor control P.C. board.
Outdoor heat exchanger tem-
perature thermistor
Lit
9 times
• Refer to 11-6. "Check of outdoor
thermistors".
4-time blink
Overcurrent
Once
Not lit
18A (
MXZ-2C20NA2
)/21 A (
0;=&&&1$
0;=&&&1$
)/28 A (
0;=&1$
0;=&&&1$+= 0;=&1$ 0;=
&&&1$+=
FXUUHQWÀRZVLQWRSRZHUPRGXOH
• Reconnect compressor connector.
• Refer to 11-6. "How to check in-
verter/compressor".
• Check the stop valve.
—
5-time blink
Discharge temperature
Lit
Lit
The discharge temperature exceeds 239°F (
MXZ-
2C20NA2
)/222.8°F (
0;=&&&1$
0;=&&&1$
)/240.8°F (
MXZ-2C20
&&1$+=&1$0;=&&
&1$+=&1$
) during operation.
Compressor can restart if discharge temperature
thermistor reads 176°F (
MXZ-2C20NA2
)
203°F
(
0;=&&&1$0;=&&
&1$
)/212°F (
0;=&&&1$+=
&1$0;=&&&1$+=&1$
)
or less 3 minutes later.
• Check refrigerant circuit and refrig-
erant amount.
• Refer to 11-6. "Check of LEV".
—
6-time blink
High pressure
Lit
Lit
The outdoor heat exchanger temperature ex-
ceeds 158°F during cooling or the indoor gas
pipe temperature exceeds 158°F during heating.
• Check refrigerant circuit and refrig-
erant amount.
• Check the stop valve.
—
7-time blink
Fin temperature
3 times
Not lit
7KH¿QWHPSHUDWXUHH[FHHGV)
0;=&&
&1$0;=&&&&1$
)/192°F
(
0;=&&&1$+=&1$0;=&
&&1$+=&1$
) during operation.
• Check around outdoor unit.
• Check outdoor unit air passage.
• Refer to 11-6. "Check of outdoor
fan motor".
—
P.C. board temperature
4 times
Not lit
The P.C. board temperature exceeds 152°F (
MXZ-
&&&1$ 0;=&&&
4C36NA2
)/189°F (
0;=&&&1$+=
0;=&1$ 0;=&&&1$+=
5C42NA2
) during operation.
8-time blink
Outdoor fan motor
Lit
Lit
A failure occurs 3 consecutive times within
30 seconds after the fan gets started.
• Refer to 11-6. "Check of outdoor
fan motor".
—
9-time blink
Outdoor control system
Lit
5 times Nonvolatile memory data cannot be read
properly.
• Replace the outdoor control P.C.
board.
ż
10-time blink
Low discharge temperature
protection
Lit
Lit
The frequency of the compressor is kept 80
Hz or more and the discharge temperature is
kept under 102.2°F for more than 20 minutes.
• Check refrigerant circuit and refrig-
erant amount.
• Refer to 11-6. "Check of LEV".
—
11-time blink
Communication error
between P.C. boards
Lit
6 times Communication error occurs between the out-
door control P.C. board and outdoor power P.C.
board for more than 10 seconds.
• Check the connecting wire between
outdoor control P.C. board and out-
door power P.C. board.
—
The communication between boards protec-
tion cut-out operates 2 consecutive times.
ż
Current sensor
Lit
7 times A short or open circuit is detected in the cur-
rent sensor during compressor operating.
—
—
Current sensor protection cut-out oper-
ates 2 consecutive times.
ż
Zero cross detecting circuit
5 times
Not lit
Zero cross signal cannot be detected
while the compressor is operating.
• Check the connecting wire among
outdoor control P.C. board and out-
door power P.C. board.
—
The protection cut-out of the zero cross de-
tecting circuit operates 10 consecutive times.
ż
Converter
5 times
Not lit
A failure is detected in the operation of the
converter during operation.
• Check the voltage of power supply.
• Replace the outdoor power P.C.
board.
—
Bus-bar voltage
5 times
Not lit
The bus-bar voltage exceeds 400 V or
falls to low level during compressor oper-
ating.
• Check the voltage of power supply.
• Replace the outdoor power P.C. board
or the outdoor control P.C. board.
15-time blink
LEV and drain pump
Lit
Lit
The indoor unit detects an abnormality in
the LEV and drain pump.
• Refer to 11-6. "Check of LEV".
• Check the drain pump of the indoor unit.
—
NOTE
: Blinking patterns of this mode differ from the ones of
TROUBLESHOOTING CHECK TABLE (11-4.).
OBH702G
Содержание MXZ-2C20NA2-U1
Страница 19: ...19 MXZ 4C36NA MXZ 4C36NA2 Unit inch mm Lock nut Conduit plates Conduit connector OBH702G ...
Страница 21: ...21 MXZ 2C20NAHZ MXZ 2C20NAHZ2 Unit inch mm Lock nut Conduit connector Conduit plate OBH702G ...
Страница 24: ...24 MXZ 3C24NA MXZ 3C30NA OBH702G ...
Страница 25: ...25 MXZ 3C24NA2 MXZ 3C30NA2 OBH702G ...
Страница 26: ...26 MXZ 4C36NA OBH702G ...
Страница 27: ...27 MXZ 4C36NA2 OBH702G ...
Страница 29: ...29 MXZ 5C42NA2 OBH702G ...
Страница 30: ...30 MXZ 2C20NAHZ OBH702G ...
Страница 31: ...31 MXZ 2C20NAHZ2 OBH702G ...
Страница 32: ...32 MXZ 3C24NAHZ MXZ 3C30NAHZ OBH702G ...
Страница 33: ...33 MXZ 3C24NAHZ2 MXZ 3C30NAHZ2 OBH702G ...