77
DISASSEMBLY INSTRUCTIONS
14
OPERATING PROCEDURE
PHOTOS
Photo 1
1. Removing the cabinet.
(1) Remove the screw fixing the service panel. (See Photo 1.)
(2) Pull down the service panel and remove it. (See Photo 1.)
(3) Disconnect the power supply and indoor/outdoor connecting wire.
(4) Remove the screws fixing the top panel. (See Photo 1.)
(5) Remove the top panel. (See Photo 1.)
(6) Remove the screws fixing the cabinet.
(7) Remove the cabinet.
(8) Remove the screws fixing the back panel.
(9) Remove the back panel.
(1) Slide the sleeve and check if there is a locking lever or not.
(2) The terminal with this connector has the
locking mechanism.
1
Slide the sleeve.
2
Pull the terminal while
pushing the locking
lever.
1
Hold the sleeve, and
pull out the terminal
slowly.
The terminal which has the locking mechanism can be detached as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
<"Terminal with locking mechanism" Detaching points>
Connector
Sleeve
Locking lever
Back
panel
Service
panel
14-1. MXZ-2A40VA
MXZ-2A52VA
OUTDOOR UNIT
Screws of
the top panel
Screw of
the cabinet
Screws
of the
top panel
Screw
of the
service
panel
Direction to
remove
Screws of
the cabinet
Hooks