20
Indoor unit
Extension pipe diameter
class
Pipe diameter
Liquid
1/4
Liquid
1/4
09
Gas
3/8
Gas
3/8
Liquid
1/4
Liquid
1/4
12
Gas
3/8
Gas
3/8
Liquid
1/4
Liquid
1/4
15
Gas
3/8
Gas
3/8
●
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes,refer to the
tables below.
●
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, see 15-1.
Outdoor unit union diameter
For
Liquid
1/4
Indoor unit A
Gas
3/8
Liquid
1/4
Indoor unit B
Gas
3/8
Unit : inch
Piping length each indoor unit (a, b)
82ft. MAX.
Total piping length (a+b)
164ft. MAX.
Bending point for each unit
25 MAX.
Total bending point
60 MAX.
❋
It does not matter which unit is higher.
a
b
Outdoor
unit
Indoor
units
49ft.
33ft.
49ft.
MAX. REFRIGERANT PIPING LENGTH & PIPE SIZE SELECTION
MXZ-2A20NA
MXZ-2A20NA -
1
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
Indoor intake air temperature
95˚FDB, 71˚FWB
67˚FDB, 57˚FWB
80˚FDB, 67˚FWB
70˚FDB, 60˚FWB
Outdoor intake air temperature
115˚FDB
14˚FDB
75˚FDB, 65˚FWB
14˚FDB, 12˚FWB
Operating Range
MXZ-2A20NA
MXZ-2A20NA -
1
OB444B--1.qxp 07.4.17 4:28 PM Page 20
Содержание MXZ-2A20NA-1
Страница 15: ...15 WIRING DIAGRAM 6 MXZ 2A20NA OB444B 1 qxp 07 4 17 4 27 PM Page 15 ...
Страница 16: ...16 MXZ 2A20NA 1 OB444B 1 qxp 07 4 17 4 28 PM Page 16 ...
Страница 17: ...17 MXZ 3A30NA OB444B 1 qxp 07 4 17 4 28 PM Page 17 ...
Страница 18: ...18 MXZ 3A30NA 1 OB444B 1 qxp 07 4 17 4 28 PM Page 18 ...
Страница 87: ...87 OB444B 3 qxp 07 4 17 1 41 PM Page 87 ...