61
OPERATING PROCEDURE
PHOTOS
3. Removing the 4-way valve
(1)Remove the top panel (Photo 1).
(2)Remove the service panel, rear panel, and pipe cover.
Recover refrigerant gas.
(3)Remove the electrical parts (Photo 2).
(4)Detach the welded parts of 4-way valve and pipe.
4. Removing the expansion valve
(1)Remove the top panel (Photo 1).
(2)Remove the service panel (Photo 1).
(Gas recovery is not required if the unit is pumped down.)
(3)Remove the front panel for removing LEV E (Photo 1, 3).
(4)Remove the electrical parts for removing LEV E (Photo 2, 3).
(5)Remove the LEV coils.
(6)Detach the welded parts of expansion valves and pipes.
4 way valve
R.V. coil
Welded parts
Photo 5
Photo 6
2. Removing the fan motor
(1)Remove the top panel, the service panel, and the front panel
(Photo 1).
(2)Disconnect the connectors CN931 and CN932 on the outdoor
electronic control P.C. board.
(3)Remove the propeller.
(4)Remove the fan motor.
Photo 4
Propeller
Propeller nut
Separator
Compressor nuts
Sound
proof
felt
Screws of the outdoor fan motor
Expansion
valves
LEV coils
OB444B--3.qxp 07.4.17 1:40 PM Page 61
Содержание MXZ-2A20NA-1
Страница 15: ...15 WIRING DIAGRAM 6 MXZ 2A20NA OB444B 1 qxp 07 4 17 4 27 PM Page 15 ...
Страница 16: ...16 MXZ 2A20NA 1 OB444B 1 qxp 07 4 17 4 28 PM Page 16 ...
Страница 17: ...17 MXZ 3A30NA OB444B 1 qxp 07 4 17 4 28 PM Page 17 ...
Страница 18: ...18 MXZ 3A30NA 1 OB444B 1 qxp 07 4 17 4 28 PM Page 18 ...
Страница 87: ...87 OB444B 3 qxp 07 4 17 1 41 PM Page 87 ...