OPERATING PROCEDURE
PHOTOS
6. Removing the compressor and 4-way valve
(1) Remove the cabinet and panels. (Refer to 1.)
(2) Remove the inverter assembly. (Refer to 2.)
(3) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
2
(0 MPa).
(4) Detach the brazed part of the suction and the discharge pipe
connected with compressor.
(5) Remove the compressor nuts.
(6) Remove the compressor.
(7) Detach the brazed part of pipes connected with 4-way valve.
Photo 9
61
Brazed parts of 4-way valve
Suction pipe
brazed part
Discharge pipe
brazed part
OBH767
Содержание MUZ-LN25VG
Страница 10: ...10 OUTLINES AND DIMENSIONS 6 Unit mm MUZ LN25VG MUZ LN35VG OBH767 ...
Страница 11: ...11 Unit mm MUZ LN50VG OBH767 ...
Страница 13: ...13 WIRING DIAGRAM 7 MUZ LN25VG MUZ LN35VG MUZ LN50VG OBH767 ...
Страница 14: ...14 MUZ LN60VG OBH767 ...