24
7-3. CONDENSING PRESSURE
Cooling
Data are based on the condition of indoor humidity 50 %.
Air flow should be set to High speed.
MUZ-HM09NA(H) MUZ-HM09NA2
6870
75
80
85
90
95
100 105
(°F)
120
140
160
180
200
(PSIG)
(PSIG)
6870
75
80
85
90
95
100 105
(°F)
280
320
360
400
440
Condensing pressure
86
80
75
70
Suction pressure
Outdoor ambient temperature
Indoor DB temperature (°F)
Outdoor ambient temperature
Indoor DB temperature (°F)
86
80
75
70
MUZ-HM12NA
-
U8
MUZ-HM12NA2
-
U8
(PSIG)
6870
75
80
85
90
95
100 105
(°F)
260
300
340
380
420
(PSIG)
6870
75
80
85
90
95
100 105
(°F)
110
130
150
170
190
Condensing pressure
86
80
75
70
Suction pressure
Indoor DB temperature (°F)
Outdoor ambient temperature
86
80
75
70
Indoor DB temperature (°F)
Outdoor ambient temperature
MUZ-HM12NA
-
U1
,
U2
MUZ-HM12NA2
-
U1
MUZ-HM12NAH
70
75
80
85
90
95
100
105
100
120
140
160
180
(PSIG)
(PSIG)
70
75
80
85
90
95
100
105
280
335
390
445
500
Condensing pressure
86
80
75
70
Suction pressure
Outdoor ambient temperature
Indoor DB temperature (°F)
Outdoor ambient temperature
Indoor DB temperature (°F)
86
80
75
70
OBH747F