3
INDOOR / OUTDOOR CORRESPONDENCE TABLE
3
SPECIFICATION
4
❈
There is no combination other than this table.
MUX-19TV-
E1
MUX-20TV-
E1
MUX-25TV-
E1
Combination of the
connectable indoor units
OUTDOOR UNIT
A:07, B:12
A:09, B:09, C:09
A:12, B:12
Outdoor model
Capacity
Dehumidification
Outdoor air flow
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20
:
)
Model
Winding
resistance(at20
:
)
Dimensions W
O
H
O
D
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity(R22)
Refrigerating oil (Model)
kW
R
/h
K
/h
A
A
W
A(kW)
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
Opetate 1 unit
A
3.5
1.6
6.01
1,280
92.6
5.68
0.33
2.65
Opetate 2 unit
A+B
3.5+2.2
1.6+0.8
8.94
2,005
97.5
8.37
0.57
2.74
MUX-19TV -
E1
Single phase
230V, 50Hz
Opetate 1 unit
B
2.2
0.8
Hi:2,460 / Lo:1,920
15
3.33
745
—
97.3
45.6
3.00
0.33
2.82
RH220VHAT (Room A) / RH135VHAT (Room B)
1,050 / 650
C-R 2.13/4.18
C-S 3.91/5.76
RA6V60-DA
WHT-BLK 90 BKL-YLW 54
BLK-RED 146
840
✕
640
✕
330
63
52
High:730 / Low:580
2
Room A : 0.87
Room B :1.0
520(MS56) / 300(MS56)
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance(C.O.P)
Outdoor unit power supply
Indoor unit No.
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor
DB27°C / WB19°C
Outdoor
DB35°C / WB(24°C)
OB284-1.qxp 01.4.26 8:59 PM Page 3