21
9-2. COOL (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a
beep tone.
(2) Select COOL mode with the OPERATION SELECT button.
(3) Press the TEMPERATURE buttons
(TOO WARM or TOO COOL button)
to select the desired temperature.
The setting range is 16 ~ 31°C
w
Indoor fan continues to operate regardless of thermostat’s OFF-
ON at set speed.
w
Coil frost prevention is as same as COOL mode of “I FEEL
CONTROL”.
9-3. DRY (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a
beep tone.
(2) Select DRY mode with the OPERATION SELECT button.
(3) The microprocessor reads the room temperature and determines
the set temperature. Set temperature is as shown on the right
chart.
Thermostat (SET TEMP.) does not work.
The other operations are as same as DRY mode of “I FEEL
CONTROL”.
(4) DRY operation will not function when the room temperature is 13°C or below.
(5) When DRY operation functions, the fan speed is lower than cool operation.
9-4. HEAT (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select HEAT mode with the OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TOO WARM or TOO COOL button) to select the desired temperature.
The setting range is 16 ~ 31°C.
(4) Indoor fan speed control, high pressure protection, defrosting, reversing valve control are the same as HEAT mode of “I
FEEL CONTROL”.
4. Reversing valve control
Heating · · · · · ON
Cooling · · · · · OFF
Dry · · · · · · · · OFF
NOTE1 : The reversing valve reverses for 5 seconds right before start-up of the compressor.
NOTE2 : Refer to the Service Manual OB227 REVISED EDITION-B when MCFH-13NV-
is connected with MXZ-32RV-
as multi system units.
E1
E3
ON
OFF
ON
OFF
ON
OFF
Compressor
Reversing valve
Outdoor fan
(COOL / DRY)
(HEAT)
5 sec.
5 sec.
35
30
25
20
15
10
:
10 15 20 25 30 35
Set temperature
Initial room temperature
Set temperature and
initial room temperature in DRY mode
:
ON
OFF
ON
OFF
ON
OFF