Humidity
Approx 30%
Approx 20%
Approx 50%
Room/air temperature
Wall/floor temperature
Advantages of i-see
Sensible
temperature
Floor
temperature
Wall
temperature
Room
temperature
8
MOVE EYE CONTROL OPERATION...Sensible temperature
The proceed of the unit’s temperature control is a gerneral temperature control proceed, that accord to the temperature
of wall, floor and room measured by MOVE EYE sensors (MOVE EYE control operation).
Starting MOVE EYE control
MOVE EYE control operation is activated when MOVE EYE button is pressed with a thin stick in manual COOL mode.
MOVE EYE control operation is activated w�en t�e remote controller is first used following replacement of t�e
batteries or resetting of the remote controller.
Note:
Cancelling MOVE EYE control
MOVE EYE control operation is canceelled when MOVE EYE button is pressed with a thin stick once again.
If the conditioner is turned OFF without cancelling MOVE EYE control operation, MOVE EYE control operation is
activated the next time the air conditioner is turned ON.
Note:
Approx 150 degrees
MOVE EYE control operation
T�e sensors constantly measure t�e room and floor/wall
temperatures to automatically adjust to the set tempera-
ture by estimating the temperature actually perceived by
a person inside the room ("sensible temperature").
"sensible temperature").
sensible temperature").
").).
Advantages:
The air inside the room is conditioned quickly to a com-
fortable condition.
The room will not become too cold or hot even when
the air conditioner is kept on for a long period.
Installation opsition
Installation
at left
Installation
at center
Installation
at right
Left
Center
Right
Image of sensing
range
Driection of sensor
When cancel MOVE EYE control, the gerneral temperature control proceed will instead.
MOVE EYE sensor
• When AREA setting is not activated, the sensing range of MOVE EYE Sensor differs depending on the installation
location of the air-conditioner.
Refer to the description for slide switch setting (Page 4).
•This setting of temperature measurement is mnemonic (previous status setting), this temperature sensor in full range may
detect t�e radiant temperature of floor / wall in t�e 150° range (one of t�ree installation spaces, left / center / rig�t); t�ere
fore, the detected temperature may be different, because the standard temperature (near measured value by market-sold
t�ermometer) is classified according to t�e temperature near t�e room or ground and/or wall.
•After maintenance or repair, please install the front frame components properly so as to detect the radiant temperature of
floor / wall.