background image

EN-16

EN

Even if these items are checked, when the unit does not recover from the 

trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?

•  Is the power supply plug connected?

•  Is the ON timer set? 

 Page 12 

The horizontal vane does not 

move.

•  Are the horizontal vane and the vertical vane 

installed correctly?

•  Is the fan guard deformed? 

•  When the breaker is turned on, the horizontal 

vanes’ position will be reset in about a minute. 

After the reset has completed, the normal hori-

zontal vanes’ operation resumes. The same is 

true in the emergency cooling operation.

The unit cannot be operated for 

about 3 minutes when restarted.

•  This protects the unit according to instructions 

from the microprocessor. Please wait.

Mist is discharged from the air 

outlet of the indoor unit.

•  The cool air from the unit rapidly cools moisture 

in the air inside the room, and it turns into mist.

The swing operation of the HORI-

ZONTAL VANE is suspended for a 

while, then restarted.

•  This is for the swing operation of the HORIZON-

TAL VANE to be performed normally.

When SWING is selected in 

COOL/DRY/FAN mode, the 

lower horizontal vane does not 

move.

•  It is normal that the lower horizontal vane does 

not move when SWING is selected in COOL/

DRY/FAN mode.

The airfl ow direction changes 

during operation.

The direction of the horizontal 

vane cannot be adjusted with 

the remote controller.

•  When  the  unit  is  operated  in  COOL  or  DRY 

mode, if the operation continues with air blow-

ing down for 0.5 to 1 hour, the direction of the 

airfl ow is automatically set to upward position 

to prevent water from condensing and dripping.

•  In  the  heating  operation,  if  the  airfl ow  tem-

perature is too low or when defrosting is being 

done, the horizontal vane is automatically set 

to horizontal position.

The operation stops for about 

10 minutes in the heating 

operation.

•  Outdoor unit is in defrost.

 

Since  this  is  completed  in  max.  10  minutes, 

please wait. (When the outside temperature is 

too low and humidity is too high, frost is formed.)

The unit starts operation by 

itself when the main power is 

turned on, but hasn’t received 

sign from the remote controller.

•  These  models  are  equipped  with  an  auto 

restart  function.  When  the  main  power  is 

turned  off  without  stopping  the  unit  with  the 

remote controller and is turned on again, the 

unit starts operation automatically in the same 

mode as the one set with the remote control-

ler just before the shutoff of the main power. 

Refer to “Auto restart function”. 

 Page 18 

The two horizontal vanes touch 

each other. The horizontal 

vanes are in an abnormal posi-

tion. The horizontal vanes do 

not return to the correct “close 

position”.

Perform one of the following: 

•  Turn off and on the breaker. Make sure the hori-

zontal vanes move to the correct “close position”.

•  Start and stop the emergency cooling operation 

and make sure the horizontal vanes move to the 

correct “close position”.

In  COOL/DRY  mode,  when  the 

room  temperature  reaches  near 

the set temperature, the outdoor 

unit  stops,  then  the  indoor  unit 

operates at low speed.

•  When the room temperature deviates from the 

set temperature, the indoor fan starts running 

according to the settings on the remote control-

ler.

The indoor unit discolors over 

time.

•  Although plastic turns yellow due to the infl uence 

of  some  factors  such  as  ultraviolet  light  and 

temperature, this has no effect on the product 

functions.

The operation indicator lamp is 

dim. The unit does not beep.

•  Is the NIGHT MODE operation set?

Multi system

The indoor unit which is not 

operating becomes warm and a 

sound, similar to water fl owing, 

is heard from the unit.

•  A small amount of refrigerant continues to fl ow 

into the indoor unit even though it is not operat-

ing.

When heating operation is 

selected, operation does not 

start right away.

•  When operation is started during defrosting of 

outdoor unit is done, it takes a few minutes (max. 

10 minutes) to blow out warm air.

Outdoor Unit

The fan of the outdoor unit does 

not rotate even though the com-

pressor is running. Even if the 

fan starts to rotate, it stops soon.

•  When  the  outside  temperature  is  low  during 

cooling operation, the fan operates intermittently 

to maintain suffi cient cooling capacity.

Water leaks from the outdoor 

unit.

•  During COOL and DRY operations, pipe or pipe 

connecting sections are cooled and this causes 

water to condense.

•  In the heating operation, water condensed on 

the heat exchanger drips down.

•  In the heating operation, the defrosting operation 

makes ice forming on the outdoor unit melt and 

drip down.

White smoke is discharged from 

the outdoor unit.

•  In the heating operation, vapor generated by the 

defrosting operation looks like white smoke.

Symptom

Explanation & Check points

Remote controller

The display on the remote 

controller does not appear or it 

is dim. The indoor unit does not 

respond to the remote control 

signal.

•  Are the batteries exhausted? 

 Page 5 

•  Is  the  polarity  (+,  -)  of  the  batteries  correct?

 Page 5 

•  Are any buttons on the remote controller of other 

electric appliances being pressed?

The operation mode cannot be 

changed.

•  Disable the OPERATION LOCK.

Does not cool or heat

The room cannot be cooled or 

heated suffi ciently.

•  Is the temperature setting appropriate? 

 

 Page 7 

•  Is  the  fan  setting  appropriate?  Please  change 

fan speed to High or Super High. 

 Page 8 

•  Are the fi lters clean? 

 Page 14 

•  Is the fan or heat exchanger of the indoor unit clean?

 

 Page 14 

 

•  Are there any obstacles blocking the air inlet or 

outlet of the indoor or outdoor unit?

•  Is a window or door open?

•  It may take a certain time to reach the setting 

temperature or may not reach that depending on 

the size of the room, the ambient temperature, 

and the like.

•  Is the NIGHT MODE operation set?

The room cannot be cooled 

suffi ciently.

•  When a ventilation fan or a gas cooker is used 

in a room, the cooling load increases, resulting 

in an insuffi cient cooling effect.

•  When the outside temperature is high, the cooling 

effect may not be suffi cient.

The room cannot be heated 

suffi ciently.

•  When the outside temperature is low, the heating 

effect may not be suffi cient.

Air does not blow out soon in 

the heating operation.

•  Please wait as the unit is preparing to blow out 

warm air.

Airfl ow

The air from the indoor unit 

smells strange.

•  Are the fi lters clean? 

 Page 14 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 14 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it out 

with the air.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/con-

traction of the front panel, etc. due to change in 

temperature.

“Burbling” sound is heard.

•  This  sound  is  heard  when  the  outside  air  is 

absorbed from the drain hose by turning on the 

range hood or the ventilation fan, making water 

fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows  into  the  drain  hose  in  case  the  outside 

wind is strong.

Mechanical sound is heard 

from the indoor unit.

•  This is the switching sound in turning on/off the 

fan or the compressor.

The sound of water fl owing is 

heard.

•  This  is  the  sound  of  refrigerant  or  condensed 

water fl owing in the unit.

Hissing sound is sometimes 

heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is changed.

Timer

Weekly timer does not operate 

according to settings.

•  Is the ON/OFF timer set? 

 Page 12 

•  Transmit  the  setting  information  of  the  weekly 

timer to the indoor unit again. When the infor-

mation is successfully received, a long beep will 

sound from the indoor unit. If information fails to 

be received, 3 short beeps will be heard. Ensure 

information is successfully received. 

 Page 13 

•  When a power failure occurs and the main power 

turns  off,  the  indoor  unit  built-in  clock  will  be 

incorrect. As a result, the weekly timer may not 

work normally.

  Be  sure  to  place  the  remote  controller  where 

the  signal  can  be  received  by  the  indoor  unit.

 Page 5 

The unit starts/stops the opera-

tion by itself.

•  Is the weekly timer set? 

 Page 13 

Wi-Fi interface

When error occurs during con-

nection setup or operation.

Refer to the SETUP MANUAL.

For SETUP MANUAL, please go to the website 

below.

http://www.melcloud.com/Support

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

JG79Y413H01_01En.indd   16

2018/01/29   16:39:06

Содержание MSZ-LN18VGB

Страница 1: ...O D ISTRUZIONI MANUAL DE INSTRUCCIONES BEDIENINGSINSTRUCTIES NOTICE D UTILISATION BEDIENUNGSANLEITUNG РЪКОВОДСТВО ЗА ЕКСПЛОАТАЦИЯ INSTRUKCJA OBSŁUGI BRUKSANVISNING KÄYTTÖOHJEET Deutsch Français Nederlands Español Italiano Ελληνικά Português Dansk Svenska Türkçe Български Polski Norsk Suomi Čeština Slovenčina Magyar Slovenščina Română Eesti Latviski Lietuviškai Hrvatski Srpski NÁVOD K OBSLUZE NÁVOD...

Страница 2: ...ngs of symbols used in this manual Be sure not to do Be sure to follow the instruction Never insert your finger or stick etc Never step onto the indoor outdoor unit and do not put anything on them Danger of electric shock Be careful Be sure to disconnect the power supply plug from the power outlet Be sure to shut off the power Risk of fire Never touch with wet hand Never splash water on the unit SAF...

Страница 3: ... indoor outdoor unit This may cause injury Do not use insecticides or flammable sprays on the unit This may cause a fire or deformation of the unit Do not expose pets or houseplants to direct airflow This may cause injury to the pets or plants Do not place other electric appliances or furniture under the indoor outdoor unit Water may drip down from the unit which may cause damage or malfunction Do no...

Страница 4: ... at their end of life should be disposed of separately from your household waste If a chemical symbol is printed beneath the symbol Fig 1 this chemical sym bol means that the battery or accumulator contains a heavy metal at a certain concentration This will be indicated as follows Hg mercury 0 0005 Cd cadmium 0 002 Pb lead 0 004 In the European Union there are separate collection systems for used ...

Страница 5: ...e it down further to get to the weekly timer buttons When the remote controller is not used place it near this unit Only use the remote controller provided with the unit Do not use other remote controllers If 2 or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controller i save button Page 10 WEEKLY TIMER set...

Страница 6: ... the polarity of the batteries is correct Do not use manganese batteries and leaking batteries The remote controller could malfunction Do not use rechargeable batteries The battery replacement indicator lights up when the battery is running low In about 7 days after the indicator starts lights up the remote controller stops working Replace all batteries with new ones of the same type Batteries can...

Страница 7: ...ollowing situations Room temperature is high A person wears heavy clothes and his her skin is not exposed A heating element of which temperature changes significantly is present Some heat sources such as a small child or pet may not be sensed A heat source and the air conditioner are more than 6 m apart A heat source does not move for a long time Do not touch the i see sensor This may cause malfun...

Страница 8: ...ightly Temperature cannot be set during DRY mode HEAT mode Enjoy warm air at your desired temperature FAN mode Circulate the air in your room Note After COOL DRY mode operation it is recommended to operate in the FAN mode to dry inside the indoor unit Note Multi system operation Two or more indoor units can be operated by one outdoor unit When several indoor units are operated simultaneously cooli...

Страница 9: ... the lower position for HEAT If the lower position is selected during COOL DRY the vane automatically moves to the upward position 1 after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently Two short beeps are heard from the indoor unit when set to AUTO Always use the remote controller when changing the direction of air flow Moving the horizonta...

Страница 10: ...e VANE or WIDE VANE buttons is pressed AIRFLOW CONTROL MODE This function automatically changes the operation to No occupancy energy saving mode or No occupancy Auto OFF mode when nobody is in the room ABSENCE DETECTION 1 To activate this No occupancy energy saving mode press until appears on the operation display of the remote controller 2 To activate this No occupancy Auto OFF mode press until a...

Страница 11: ...for COOL ECONO COOL HEAT mode and NIGHT MODE operation This enables you to select your preferred setting with a single push of the button A simplified set back function enables to recall the preferred preset setting with a single push of the button Press the button again and you can go back to the previous setting in an instance ECONO COOL OPERATION Press during COOL mode page 7 to start ECONO COOL...

Страница 12: ...t decrease during Multi system operation AIR PURIFYING OPERATION Press to start AIR PURIFYING operation AIR PURIFYING lamp turns on Display section Press again to cancel AIR PURIFYING opera tion AIR PURIFYING lamp turns off Display section Note Never touch the air purifying device during operation Although the air pu rifying device is safety conscious design touching this device could be the cause...

Страница 13: ...1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time and day are set correctly Page 5 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Set the timer while or is blinking 3 Press or again to cancel timer Note ON ...

Страница 14: ...r OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is included among them will b...

Страница 15: ...e Every 3 months Remove dirt by a vacuum cleaner When dirt cannot be removed by vacuum cleaning Soak the filter together with its frame in lukewarm water and rinse it After washing dry it well in shade and This information is based on REGULATION EU No 528 2012 MODEL NAME Treated Article Parts name Active Substances CAS No Property Instruction for Use Safe handling information MAC 2390FT E FILTER Si...

Страница 16: ...ite below http www melcloud com Support Note Ensure that the Router supports the WPA2 AES encryption setting before starting the Wi Fi interface setup The End user should read and accept the terms and conditions of the Wi Fi service before using this Wi Fi interface To complete connection of this Wi Fi interface to the Wi Fi service the Rout er may be required This Wi Fi interface will not commenc...

Страница 17: ...s not rotate even though the com pressor is running Even if the fan starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation w...

Страница 18: ...uently The remote control signal is not received in a room where an electronic ON OFF type fluorescent lamp inverter type fluorescent lamp etc is used Operation of the air conditioner interferes with radio or TV reception An amplifier may be required for the affected device When an abnormal sound is heard When any refrigerant leakage is found WHEN YOU THINK THAT TROUBLE HAS OCCURRED JG79Y413H01_01En ...

Страница 19: ...ler When using the air conditioner again 1 Clean the air filter Page 14 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly 4 Refer to the PREPARATION BEFORE OPERATION and follow the instructions Page 5 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME To prevent the effects of a fluorescent lamp keep as f...

Страница 20: ... 45 41 37 29 Outdoor dB A 46 49 49 50 51 54 51 54 55 55 Indoor Outdoor MUZ LN25 35 50 60VG MUZ LN25 35 50VGHZ Cooling Upper limit 32 C DB 23 C WB 46 C DB 46 C DB Lower limit 21 C DB 15 C WB 10 C DB 10 C DB Heating Upper limit 27 C DB 24 C DB 18 C WB 24 C DB 18 C WB Lower limit 20 C DB 15 C DB 16 C WB 25 C DB 26 C WB Guaranteed operating range SPECIFICATIONS Wi Fi interface Model MAC 567IFB E Input...

Страница 21: ...rretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scandinavian Branch Hammarbacken 14 P O Box 750 SE 19127 Sollentuna Sweden UK Branch Travellers Lane Hatfield Herts AL10 8XB England U K Polish Branch Krakowska 50 PL 32 083 Balice Poland MITSUBISHI ELECTRIC TURKEY ELEKTRİK ÜRÜNLERI A Ş Şerifali Mah Kale Sok No 41 34775 Ümraniye İstanbul Turkey Wi Fi interface setting infor...

Страница 22: ...jeni za upotrebu u stambenim i poslovnim okruženjima te okruženjima lake industrije ovim izjavljuje na svoju isključivu odgovornost da su klima uređaji i toplotne pumpe opisane u daljem tekstu za upotrebu u stambenim komercijalnim okruženjima i okruženjima sa lakom industrijom настоящим заявляет и берет на себя исключительную ответственность за то что кондиционеры и тепловые насосы описанные ниже ...

Отзывы: