En-8
Airfl ow Control mode offers air conditioning according to a location of
an occupant in a room detected by move eye sensor.
1
Press
during COOL, DRY, HEAT or AUTO
mode to activate the AIRFLOW CONTROL mode. This
mode is only available when the move eye control
mode is effective.
2
Each press of
changes AIRFLOW CONTROL
in the following order:
(INDIRECT) : An occupant will be less exposed to
direct airfl ow.
(DIRECT) : Mainly the vicinity of an occupant will
be air-conditioned.
(EVEN)
: The unit learns the area where an
occupant spend most of the time,
and evens out the temperature of
that area.
• Horizontal and vertical airflow directions will be automatically selected.
• When more than a couple of people are in a room, the AIRFLOW
CONTROL mode may work less effectively.
• If you still feel uncomfortable with the air direction determined by the
INDIRECT mode, adjust the air direction manually.
Page 7
3
Cancelling the move eye control mode automatically
cancels the AIRFLOW CONTROL mode.
• The AIRFLOW CONTROL mode is also cancelled when the VANE or
WIDE VANE buttons is pressed.
A
IRFLOW CONTROL MODE
This function automatically changes the operation to No occupancy
energy-saving mode or No occupancy Auto-OFF mode when nobody
is in the room.
A
BSENCE DETECTION
1
To activate this No occupancy energy-saving mode,
press
until
appears on the operation display
of the remote controller.
2
To activate this No occupancy Auto-OFF mode, press
until
appears on the operation display of the
remote controller.
3
Press
again to cancel the ABSENCE DETEC-
TION.
• Even if the unit is turned OFF due to No occupancy Auto-OFF mode,
the display of the remote controller remains to indicate the unit is in
operation. Press
then press
again to restart opera-
tion.
• When OFF timer is set, a priority is given to OFF timer.
• No occupancy energy saving mode or No occupancy Auto-OFF mode
are not available during POWERFUL operation.
• The unit will not be turned off if no one is detected during normal
operation mode, even though No occupancy Auto-OFF mode is acti-
vated.
(INDIRECT) (DIRECT)
(EVEN)
(OFF)
Energy-
saving
mode
Auto-OFF
mode
No
occupancy
detected
Occupancy
detected
About
10 min.
Normal
Normal
Normal
About 1 HR.
Saving energy
Saving more
Turn OFF
Saving energy
Cancel
JG79Y185H01_en.indd 8
11/29/2016 8:48:13 AM
Содержание MSZ-LN09VFB
Страница 34: ...A4_white_tombo indd 1 2016 04 25 10 16 47 ...
Страница 35: ...A4_white_tombo indd 1 2016 04 25 10 16 47 ...