Mitsubishi Electric MSZ-FH25VE Скачать руководство пользователя страница 7

En-6

 AUTO mode (Auto change over)

The unit selects the operation mode according to the difference between the 

room temperature and the set temperature. During AUTO mode, the unit 

changes mode (COOL↔HEAT) when the room temperature is 2°C away 

from the set temperature for more than 15 minutes.

Note: 

Auto Mode is not recommended if this indoor unit is connected to a MXZ 

type outdoor unit. When several indoor units are operated simultaneously, 

the unit may not be able to switch operation mode between COOL and 

HEAT. In this case, the indoor unit becomes standby mode (Refer to table 

of Operation indicator lamp).

 COOL mode

Enjoy cool air at your desired temperature. 

Note: 

Do not operate COOL mode at very low outside temperatures (less than 

-10°C). Water condensed in the unit may drip and wet or damage furni-

ture, etc.

  DRY mode

Dehumidify your room. The room may be cooled slightly. 

Temperature cannot be set during DRY mode.

 HEAT mode

Enjoy warm air at your desired temperature.

  FAN mode

Circulate the air in your room.

Note: 

After COOL/DRY mode operation, it is recommended to operate in the 

FAN mode to dry inside the indoor unit.

Operation indicator lamp

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation 

switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in 

the following order:

1

Press

 

 

to start the operation.

2

Press 

 to select operation mode. Each press 

changes mode in the following order:

3

Press 

 or 

 to set the temperature.

Each press raises or lowers the temperature by 1°C.

 

Press 

 to stop the operation.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto 

restart function” automatically starts operation in the same mode as the one 

set with the remote controller just before the shutoff of the main power. When 

timer is set, timer setting is cancelled and the unit starts operation when power 

is resumed.

If you do not want to use this function, please consult the service repre-

sentative because the setting of the unit needs to be changed.

S

ELECTING OPERATION MODES

Set temperature : 24°C

Fan speed : Medium

Horizontal vane : Auto

Emergency COOL

Emergency HEAT

Stop

Note:

•  The fi rst 30 minutes of operation is test run. Temperature 

control does not work, and fan speed is set to High.

•  In the emergency heating operation, the fan speed gradu-

ally rises to blow out warm air.

•  In the emergency cooling operation, the horizontal vanes’ 

position will be reset in about a minute, then the operation 

will start.

 (AUTO)  (COOL) 

(DRY) 

(HEAT) 

(FAN)

Note:

Multi system operation

Two or more indoor units can be operated by one outdoor unit. When several 

indoor units are operated simultaneously, cooling/dry/fan and heating opera-

tions cannot be done at the same time. When COOL/DRY/FAN is selected 

with one unit and HEAT with another or vice versa, the unit selected last goes 

into standby mode.

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Standby mode (only during multi system operation)

  Lighted 

  Blinking

SG79F661H02_en.indd   6

2012/12/18 (火)   午後 1:28:16

Содержание MSZ-FH25VE

Страница 1: ...η Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια βεβαι ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή ση LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente ed in tutta sicurezza questo apparecchio leggere il presente libretto d istruzioni prima dell uso MANUAL DE INSTRUCCIONES Para los clientes Para utilizar esta unidad de forma correcta y segura l...

Страница 2: ...rience and knowledge unless they have been given supervision or instruction concerning use of the appli ance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case...

Страница 3: ...ulate dirt which may cause overheating or fire Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with your skin or clothes wash them thoroughly with clean water If the battery fluid comes in contact with your eyes wash them thoroughly with clean wa...

Страница 4: ...te 10 minutes when pressed longer 3 Press the DAY button to set the day Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section ON OFF operate stop button Temperature buttons Page 6 Operation select button Page 6 ECONO COOL button Page 8 FAN speed control button Page 7 VANE cont...

Страница 5: ... is less than 50 cm to the right Area Left Center Right Remote controller display Hold down on the remote controller for 2 sec onds to enter the position setting mode Select the target installation position by pressing Each press of the displays the positions in order Press to complete the position setting Note The installation position can be set only when all the following conditions are met The...

Страница 6: ...ct ed When more than a couple of people are in a room the INDIRECT DI RECT mode may work less effectively If you still feel uncomfortable with the air direction determined by the INDIRECT mode adjust the air direction manually Page 7 3 Canceling the i see control mode automatically cancels the INDIRECT DIRECT mode The INDIRECT DIRECT mode is also cancelled when the VANE or WIDE VANE buttons is pre...

Страница 7: ...de Each press changes mode in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of t...

Страница 8: ...ands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 12 The right and left horizontal vanes set to the same level may not align perfectly Press to select horizontal airflow dire...

Страница 9: ...an go back to the previous setting in an instance Example of use 1 Low energy mode Set the temperature 2 C to 3 C warmer in COOL and cooler in HEAT mode This setting is suitable for unoccupied room and while you are sleeping 2 Saving frequently used settings Save your preferred setting for COOL ECONO COOL and HEAT This ena bles you to select your preferred setting with a single push of the button ...

Страница 10: ... as this device discharge high voltage electricity A hissing sound may be heard during the air purifying operation This sound is produced when plasma is being discharged This is not a malfunction Air purifying lamp does not turn on if the front panel is not closed completely Press during COOL or HEAT mode page 6 to start POWERFUL operation Fan speed Exclusive speed for POWERFUL mode Horizontal van...

Страница 11: ...weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is included among ...

Страница 12: ...filters every 2 weeks Do not touch the i see sensor The air purifying device does not function for safety for a couple minutes after the operation starts or the front panel is opened closed Do not disassemble the air purifying device Do not touch any parts other than the frame of the air purifying device Front panel Air cleaning filter Electrostatic anti allergy enzyme filter blue Every 3 months Remo...

Страница 13: ...g Even if the fan starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In...

Страница 14: ...ditioner contributes to favorable conditions for growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 11 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is...

Страница 15: ...t Opmerking het serienummer staat op het naamplaatje van het product Nota El número de serie se encuentra en la placa que contiene el nombre del producto Nota il numero di serie si trova sulla targhetta del prodotto Σημείωση Ο σειριακός του αριθμός βρίσκεται στην πινακίδα ονόματος του προϊόντος Nota o número de série encontra se na placa que contém o nome do produto Bemærk Serienummeret står på pr...

Отзывы: