36
OPERATION INDICATOR
Lit
Blinking
Not lit
No.
Abnormal
point
Operation indicator lamp
Symptom
Condition
Remedy
1
MXZ type
Operation
mode
setting
Upper lamp lights and lower lamp blinks.
2.5-second OFF
Outdoor unit
operates but
indoor unit does
not operate.
The operation mode of the each indoor unit is
differently set to COOL (includes DRY) and
HEAT at the same time, the operation mode of
the indoor unit that has operated at first has
the priority.
• Unify the operation mode.
Refer to outdoor unit service
manual.
10-5. TROUBLESHOOTING CRITERION OF MAIN PARTS
Part name
Check method and criterion
Figure
Room temperature
thermistor (RT11)
Indoor coil thermistor
(RT12, RT13)
Measure the resistance with a multimeter.
Refer to 10-7. “Test point diagram and voltage”, “Indoor electronic control
P.C. board”, for the chart of thermistor.
Indoor fan motor (MF)
Check 10-6. “Check of indoor fan motor”.
Vane motor (MV1)
(Horizontal Upper)
Measure the resistance between the terminals with a multimeter.
(Temperature: 10 to 30°C)
Color of the lead wire
Normal
RED - SKY*
262 - 328 Ω
SKY
SKY
RED
SKY
SKY
Vane motor (MV2)
(Horizontal Lower)
Measure the resistance between the terminals with a multimeter.
(Temperature: 10 to 30°C)
Color of the lead wire
Normal
RED - SKY*
257 - 333 Ω
Vane motor (MV3)
(Vertical)
Measure the resistance between the terminals with a multimeter.
(Temperature: 10 to 30°C)
Color of the lead wire
Normal
RED - SKY*
219 - 273 Ω
AIR PURIFYING power
Check 10-6. .
*SKY = SKY BLUE
OPERATION INDICATOR
Lit
Blinking
Not lit
No.
Abnormal
point
Operation indicator lamp
Symptom
Condition
Remedy
1
AIR
PURIFYING
power
control
AIR PURIFYING lamp blinks.
2.5-second OFF
Indoor unit and
outdoor unit do
not operate.
When AIR PURIFYING power cannot be
turned OFF even if the AIR PURIFYING
operation is turned OFF by remote controller.
• Refer to 10-6. “Check of AIR
PURIFYING power”.
OBH932
Содержание MSZ-AY25VG-ET1
Страница 8: ...8 WIRING DIAGRAM 6 MSZ AY50VG ET1 MSZ AY25VG ET1 MSZ AY35VG ET1 MSZ AY42VG ET1 OBH932 ...
Страница 9: ...9 MSZ AY50VGK E1 SC1 ER1 MSZ AY25VGK E1 SC1 ER1 MSZ AY35VGK E1 SC1 ER1 MSZ AY42VGK E1 SC1 ER1 OBH932 ...
Страница 10: ...10 MSZ AY50VGK ET1 MSZ AY25VGK ET1 MSZ AY35VGK ET1 MSZ AY42VGK ET1 OBH932 ...
Страница 11: ...11 MSZ AY50VGKP E1 SC1 ER1 MSZ AY25VGKP E1 SC1 ER1 MSZ AY35VGKP E1 SC1 ER1 MSZ AY42VGKP E1 SC1 ER1 OBH932 ...
Страница 12: ...12 MSZ AY50VGKP ET1 MSZ AY25VGKP ET1 MSZ AY35VGKP ET1 MSZ AY42VGKP ET1 OBH932 ...