27
9-10. i-save ( ) OPERATION
1. How to set i-save operation
(1) Press OFF/ON (stop/operate) button.
(2) Select COOL, HEAT or ECONO COOL mode.
(3) Press i-save button.
(4) Set the temperature, fan speed, and airflow direction for i-save operation.
NOTE:
• i-save operation cannot be selected during DRY or AUTO mode operation.
• The setting range of HEAT mode i-save operation is 10 - 31°C.
• 2 groups of setting can be saved. (One for COOL/ECONO COOL, one for HEAT)
2. How to cancel operation
• Press i-save button again.
• i-save operation can also be cancelled by pressing Operation select button to change the operation mode.
The preferred setting can be saved for the next time with a single press of i-save button.
9-11. OPERATION LOCK
This function locks operation mode only. Other functions, such as OFF/ON, temperature setting, or airflow direction adjust-
ment, are available.
(1) Hold down
button and
button simultaneously for 2 seconds while the unit is not operating to enable
OPERATION LOCK.
The icon for the locked operation mode blinks.
(2) Hold down
button and
button simultaneously for 2 seconds again while the unit is not operating to disable
OPERATION LOCK.
• The icon for the locked operation mode blinks when
button and
button are held down to enable or disable
OPERATION LOCK or
button is pressed during operation while OPERATION LOCK is enabled.
• AIR PURIFYING operation is not available when OPERATION LOCK is enabled in a mode other than FAN mode.
9-12. AIR PURIFYING ( ) OPERATION (MSZ-AY·VGKP)
In the AIR PURIFYING operation, the indoor unit built-in device reduces airborne fungi, viruses, mold, and allergens.
(1) Press PURIFIER button to start AIR PURIFYING operation.
• AIR PURIFYING lamp turns on. (Display section)
(2) Press PURIFIER button again to cancel AIR PURIFYING operation.
• AIR PURIFYING lamp turns off. (Display section)
NOTE:
• Never touch the air purifying device during operation. Although the air purifying device is safety-conscious design, touching
this device could be the cause of trouble as this device discharge high voltage electricity.
• A “hissing” sound may be heard during the air purifying operation. This sound is produced when plasma is being dis-
charged. This is not a malfunction.
• AIR PURIFYING lamp does not turn on if the front panel is not closed completely.
9-13. SELF CLEAN (
) OPERATION
• When SELF CLEAN operation is set, it performs for 25 minutes when unit is stopped after COOL/DRY operation.
SELF CLEAN operation performs when: COOL/DRY is operated more than 3 minutes.
• The fan is stopped for the first 3 minutes. Then, the horizontal vane is set to higher than angle 1 and the fan is operated for
25 minutes.
OBH932
Содержание MSZ-AY25VG-ET1
Страница 8: ...8 WIRING DIAGRAM 6 MSZ AY50VG ET1 MSZ AY25VG ET1 MSZ AY35VG ET1 MSZ AY42VG ET1 OBH932 ...
Страница 9: ...9 MSZ AY50VGK E1 SC1 ER1 MSZ AY25VGK E1 SC1 ER1 MSZ AY35VGK E1 SC1 ER1 MSZ AY42VGK E1 SC1 ER1 OBH932 ...
Страница 10: ...10 MSZ AY50VGK ET1 MSZ AY25VGK ET1 MSZ AY35VGK ET1 MSZ AY42VGK ET1 OBH932 ...
Страница 11: ...11 MSZ AY50VGKP E1 SC1 ER1 MSZ AY25VGKP E1 SC1 ER1 MSZ AY35VGKP E1 SC1 ER1 MSZ AY42VGKP E1 SC1 ER1 OBH932 ...
Страница 12: ...12 MSZ AY50VGKP ET1 MSZ AY25VGKP ET1 MSZ AY35VGKP ET1 MSZ AY42VGKP ET1 OBH932 ...